1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
|
BEGIN NEW DATA CASE
C BENCHMARK DC-20
C TACS test having no electric network. Three transfer functions are
C involved, with two being cascaded together (note OUT1 feeds OUT2).
C The third, OUT3, is of second order. Both sinusoidal (Type-14) and
C constant (Type-11) sources are involved, and both are present during
C the steady-state solution, although they are mathematically disconnected.
C 11 February 2001, add the following line to demonstrate that the
C answer does not change if Dube's logic for supplemental variables
C is replaced by the pocket calculator. On the other hand, this is
C no great feat since the data involves no supplemental variables!
C TACS ASSEMBLY LANGUAGE { Temporary request for use of pocket calculator
TACS POCKET CALCULATOR { 12 January 2001, this new line replaces preceding
.05 1.0
1 1 1 1 1
TACS STAND ALONE
1OUT1 +GEN
1.0
1.0 1.0
1OUT2 +OUT1
1.0
1.0
1DC*10 +DC 10.
1.0 1.0
1.0
2OUT3 +GEN
1.0
1.0 2.0 1.0
11DC 1.0 -1.
14GEN 100. 1.0 -1.
33OUT1 OUT2 DC*10 OUT3 TIMEX ISTEP DELTATFREQHZOMEGARZERO PLUS1 MINUS1UNITY
33INFNTYPI DC GEN
C The TACS ac steady-state phasor solution for frequency 1.00000000E+00 follo
C Name Real part Imaginary part Magnitude Degrees
C OUT3 -2.3483896115E+00 -7.6694251071E-01 2.4704523032E+00 -161.913878
C DC*10 0.0000000000E+00 0.0000000000E+00 0.0000000000E+00 0.000000
C OUT2 9.7529547697E+01 1.5522309613E+01 9.8757049215E+01 9.043061
C OUT1 2.4704523032E+00 -1.5522309613E+01 1.5717672548E+01 -80.956939
C Zero-frequency (dc) steady-state solution for TACS follows.
C (Name) TACS value (Name) TACS value (Name) TACS value
C OUT3 0.00000000E+00 DC*10 1.00000000E+01 OUT2 0.00000000E+00
C ISTEP 0.00000000E+00 DELTAT 5.00000000E-02 FREQHZ 1.00000000E+00
C PLUS1 1.00000000E+00 MINUS1 -1.00000000E+00 UNITY 1.00000000E+00
C DC 1.00000000E+00 GEN 0.00000000E+00
BLANK card ending all TACS data cards
PRINTER PLOT
C 20 1.0 2.44544812 97.5545519 10. -2.2965486 1.0 20. .05
C 1.0 -1. 1.0 .1E20 3.14159265 1.0 100.
C maxima : 15.4314771 97.5545519 10. 2.43100116 1.0 20. .05
C 1.0 -1. 1.0 .1E20 3.14159265 1.0 100.
C Times of maxima : .25 1.0 0.0 .45 1.0 1.0 0.0
C 0.0 0.0 0.0 0.0 0.0 0.0 0.0
C minima : -15.381996 -97.593085 10. -2.4154432 0.0 0.0 .05
C 1.0 -1. 1.0 .1E20 3.14159265 1.0 -100.
C Times of minima : .75 0.5 0.0 .95 0.0 0.0 0.0
C 0.0 0.0 0.0 0.0 0.0 0.0 0.5
143 .2 0.0 1.0 OUT1 OUT2 OUT3 { Axis limits: (-9.759, 9.755)
BLANK card ending plot cards
BEGIN NEW DATA CASE
C 2nd of 3 parts of DC-20. TACS-only, with multiple-frequency sinusoidal
C steady-state solution (400 and 10 Hz), plus constant (dc) solution.
C 1 February 2002, previously-neglected need to cancel TPC is satisfied
C by the following TPC OFF declaration. Of course, this has no effect
C since no supplemental variables are being used here, anyway. There is
C no pocket calculator use, so nothing to turn off, in fact. But we go
C through the motions, anyway, as an illustration of the new declaration:
TACS POCKET CALCULATOR OFF { 1 February 2002, illustrate this new cancellation
.0001 0.02
1 1 1 1 1 -1
10 10 100 100
TACS STAND ALONE
1OUT1 +GEN1
1.0
1.0 1.0
1OUT2 +GEN2
1.0
1.0 1.0
1OUT3 +DC
1.0
1.0 1.0
1OUT4 +GEN1 +GEN2 +DC
1.0
1.0 1.0
11DC 1.0 -1.
14GEN1 10000. 400.0 -1.
14GEN2 1000. 10.0 -1.
33OUT1 OUT2 OUT3 OUT4
C Step Time TACS TACS TACS TACS
C OUT1 OUT2 OUT3 OUT4
C 0 0.0 .001583143 .253238813 1.0 1.25482196
C 1 .1E-3 .985825353 .353207504 1.0 2.33903286
BLANK card terminates the last TACS data card.
PRINTER PLOT
C 200 .02 .001582814 15.2109079 1.0 16.2124907
C Variable maxima : 3.95021189 15.2109079 1.0 19.4959527
C Times of maxima : .6E-3 .02 0.0 .0181
C Variable minima : -3.9499822 .253238813 1.0 -.84075309
C Times of minima : .0194 0.0 0.0 .0018
144 1. 0.0 10. OUT4 { Axis limits: (-0.084, 1.295)
BLANK card terminates all plot cards.
BEGIN NEW DATA CASE
C 3rd of 3 parts of DC-20. Continued test of multiple-frequency solution
C capability, only with the addition of an electric network. To the TACS
C generators of 400 and 10 Hz is added the 50 Hz of the electric network.
.0001 0.02
1 1 1 1 1 -1
10 10 100 100
TACS HYBRID
1OUT1 +GEN1
1.0
1.0 1.0
1OUT2 +GEN2
1.0
1.0 1.0
1OUT3 +DC
1.0
1.0 1.0
1OUT4 +NOD1
1.0
1.0 1.0
1OUT5 +NOD2
1.0
1.0 1.0
1OUT6 +GEN1 +GEN2 +DC
1.0
1.0 1.0
1OUT7 +DC +GEN1 +NOD1 +NOD2 +GEN2
1.0
1.0 1.0
11DC 1.0 -1.
14GEN1 100000. 400.0 -1.
14GEN2 1000. 10.0 -1.
90NOD1 50.0 -1.
91NOD2 50.0 -1.
33OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7
BLANK card ends final TACS data
NOD1 NOD2 1.00
BLANK card after last electric network branch
NOD2 -1.0 1.0
BLANK card ends switches
14NOD1 -1 100.0 50.0 -1.0
BLANK card after last electric network source
NOD1
C Zero-frequency (dc) steady-state solution for TACS follows.
C (Name) TACS value (Name) TACS value (Name) TACS value
C OUT7 1.00000000E+00 OUT6 1.00000000E+00 OUT5 0.00000000E+00
C OUT2 0.00000000E+00 OUT1 0.00000000E+00 TIMEX 0.00000000E+00
C FREQHZ 4.00000000E+02 OMEGAR 2.51327412E+03 ZERO 0.00000000E+00
C UNITY 1.00000000E+00 INFNTY 1.00000000E+19 PI 3.14159265E+00
C GEN2 0.00000000E+00 NOD1 0.00000000E+00 NOD2 0.00000000E+00
C Step Time NOD1 TACS TACS TACS TACS TACS
C OUT1 OUT2 OUT3 OUT4 OUT5
C *** Phasor I(0) = 0.1000000E+03 Switch "NOD2 " to " " closed
C 0 0.0 100. .015831432 .253238813 1.0 .001013202 .001013202
C 1 .1E-3 99.950656 9.85825353 .353207504 1.0 .011010133 .011010133
BLANK card ends selective node voltage outputs
C Last step: 200 .02 100. .015828137 15.2109079 1.0 .001013198
C Last step continued: .001013198 16.226736 16.2287624
C Final 6 maxima : 15.2109079 1.0 .318280647 .318280647 55.0478571 54.6917329
C Associated times : .02 0.0 .005 .005 .0181 .0181
PRINTER PLOT
194 1. 0.0 10. TACS OUT7 { Axis limits: (-3.599, 4.883)
BLANK card terminating plotting
BEGIN NEW DATA CASE
BLANK
|