diff options
Diffstat (limited to 'benchmarks/dc20.dat')
-rw-r--r-- | benchmarks/dc20.dat | 166 |
1 files changed, 166 insertions, 0 deletions
diff --git a/benchmarks/dc20.dat b/benchmarks/dc20.dat new file mode 100644 index 0000000..8308fc5 --- /dev/null +++ b/benchmarks/dc20.dat @@ -0,0 +1,166 @@ +BEGIN NEW DATA CASE
+C BENCHMARK DC-20
+C TACS test having no electric network. Three transfer functions are
+C involved, with two being cascaded together (note OUT1 feeds OUT2).
+C The third, OUT3, is of second order. Both sinusoidal (Type-14) and
+C constant (Type-11) sources are involved, and both are present during
+C the steady-state solution, although they are mathematically disconnected.
+C 11 February 2001, add the following line to demonstrate that the
+C answer does not change if Dube's logic for supplemental variables
+C is replaced by the pocket calculator. On the other hand, this is
+C no great feat since the data involves no supplemental variables!
+C TACS ASSEMBLY LANGUAGE { Temporary request for use of pocket calculator
+TACS POCKET CALCULATOR { 12 January 2001, this new line replaces preceding
+ .05 1.0
+ 1 1 1 1 1
+TACS STAND ALONE
+ 1OUT1 +GEN
+ 1.0
+ 1.0 1.0
+ 1OUT2 +OUT1
+ 1.0
+ 1.0
+ 1DC*10 +DC 10.
+ 1.0 1.0
+ 1.0
+ 2OUT3 +GEN
+ 1.0
+ 1.0 2.0 1.0
+11DC 1.0 -1.
+14GEN 100. 1.0 -1.
+33OUT1 OUT2 DC*10 OUT3 TIMEX ISTEP DELTATFREQHZOMEGARZERO PLUS1 MINUS1UNITY
+33INFNTYPI DC GEN
+C The TACS ac steady-state phasor solution for frequency 1.00000000E+00 follo
+C Name Real part Imaginary part Magnitude Degrees
+C OUT3 -2.3483896115E+00 -7.6694251071E-01 2.4704523032E+00 -161.913878
+C DC*10 0.0000000000E+00 0.0000000000E+00 0.0000000000E+00 0.000000
+C OUT2 9.7529547697E+01 1.5522309613E+01 9.8757049215E+01 9.043061
+C OUT1 2.4704523032E+00 -1.5522309613E+01 1.5717672548E+01 -80.956939
+C Zero-frequency (dc) steady-state solution for TACS follows.
+C (Name) TACS value (Name) TACS value (Name) TACS value
+C OUT3 0.00000000E+00 DC*10 1.00000000E+01 OUT2 0.00000000E+00
+C ISTEP 0.00000000E+00 DELTAT 5.00000000E-02 FREQHZ 1.00000000E+00
+C PLUS1 1.00000000E+00 MINUS1 -1.00000000E+00 UNITY 1.00000000E+00
+C DC 1.00000000E+00 GEN 0.00000000E+00
+BLANK card ending all TACS data cards
+ PRINTER PLOT
+C 20 1.0 2.44544812 97.5545519 10. -2.2965486 1.0 20. .05
+C 1.0 -1. 1.0 .1E20 3.14159265 1.0 100.
+C maxima : 15.4314771 97.5545519 10. 2.43100116 1.0 20. .05
+C 1.0 -1. 1.0 .1E20 3.14159265 1.0 100.
+C Times of maxima : .25 1.0 0.0 .45 1.0 1.0 0.0
+C 0.0 0.0 0.0 0.0 0.0 0.0 0.0
+C minima : -15.381996 -97.593085 10. -2.4154432 0.0 0.0 .05
+C 1.0 -1. 1.0 .1E20 3.14159265 1.0 -100.
+C Times of minima : .75 0.5 0.0 .95 0.0 0.0 0.0
+C 0.0 0.0 0.0 0.0 0.0 0.0 0.5
+ 143 .2 0.0 1.0 OUT1 OUT2 OUT3 { Axis limits: (-9.759, 9.755)
+BLANK card ending plot cards
+BEGIN NEW DATA CASE
+C 2nd of 3 parts of DC-20. TACS-only, with multiple-frequency sinusoidal
+C steady-state solution (400 and 10 Hz), plus constant (dc) solution.
+C 1 February 2002, previously-neglected need to cancel TPC is satisfied
+C by the following TPC OFF declaration. Of course, this has no effect
+C since no supplemental variables are being used here, anyway. There is
+C no pocket calculator use, so nothing to turn off, in fact. But we go
+C through the motions, anyway, as an illustration of the new declaration:
+TACS POCKET CALCULATOR OFF { 1 February 2002, illustrate this new cancellation
+ .0001 0.02
+ 1 1 1 1 1 -1
+ 10 10 100 100
+TACS STAND ALONE
+ 1OUT1 +GEN1
+ 1.0
+ 1.0 1.0
+ 1OUT2 +GEN2
+ 1.0
+ 1.0 1.0
+ 1OUT3 +DC
+ 1.0
+ 1.0 1.0
+ 1OUT4 +GEN1 +GEN2 +DC
+ 1.0
+ 1.0 1.0
+11DC 1.0 -1.
+14GEN1 10000. 400.0 -1.
+14GEN2 1000. 10.0 -1.
+33OUT1 OUT2 OUT3 OUT4
+C Step Time TACS TACS TACS TACS
+C OUT1 OUT2 OUT3 OUT4
+C 0 0.0 .001583143 .253238813 1.0 1.25482196
+C 1 .1E-3 .985825353 .353207504 1.0 2.33903286
+BLANK card terminates the last TACS data card.
+ PRINTER PLOT
+C 200 .02 .001582814 15.2109079 1.0 16.2124907
+C Variable maxima : 3.95021189 15.2109079 1.0 19.4959527
+C Times of maxima : .6E-3 .02 0.0 .0181
+C Variable minima : -3.9499822 .253238813 1.0 -.84075309
+C Times of minima : .0194 0.0 0.0 .0018
+ 144 1. 0.0 10. OUT4 { Axis limits: (-0.084, 1.295)
+BLANK card terminates all plot cards.
+BEGIN NEW DATA CASE
+C 3rd of 3 parts of DC-20. Continued test of multiple-frequency solution
+C capability, only with the addition of an electric network. To the TACS
+C generators of 400 and 10 Hz is added the 50 Hz of the electric network.
+ .0001 0.02
+ 1 1 1 1 1 -1
+ 10 10 100 100
+TACS HYBRID
+ 1OUT1 +GEN1
+ 1.0
+ 1.0 1.0
+ 1OUT2 +GEN2
+ 1.0
+ 1.0 1.0
+ 1OUT3 +DC
+ 1.0
+ 1.0 1.0
+ 1OUT4 +NOD1
+ 1.0
+ 1.0 1.0
+ 1OUT5 +NOD2
+ 1.0
+ 1.0 1.0
+ 1OUT6 +GEN1 +GEN2 +DC
+ 1.0
+ 1.0 1.0
+ 1OUT7 +DC +GEN1 +NOD1 +NOD2 +GEN2
+ 1.0
+ 1.0 1.0
+11DC 1.0 -1.
+14GEN1 100000. 400.0 -1.
+14GEN2 1000. 10.0 -1.
+90NOD1 50.0 -1.
+91NOD2 50.0 -1.
+33OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7
+BLANK card ends final TACS data
+ NOD1 NOD2 1.00
+BLANK card after last electric network branch
+ NOD2 -1.0 1.0
+BLANK card ends switches
+14NOD1 -1 100.0 50.0 -1.0
+BLANK card after last electric network source
+ NOD1
+C Zero-frequency (dc) steady-state solution for TACS follows.
+C (Name) TACS value (Name) TACS value (Name) TACS value
+C OUT7 1.00000000E+00 OUT6 1.00000000E+00 OUT5 0.00000000E+00
+C OUT2 0.00000000E+00 OUT1 0.00000000E+00 TIMEX 0.00000000E+00
+C FREQHZ 4.00000000E+02 OMEGAR 2.51327412E+03 ZERO 0.00000000E+00
+C UNITY 1.00000000E+00 INFNTY 1.00000000E+19 PI 3.14159265E+00
+C GEN2 0.00000000E+00 NOD1 0.00000000E+00 NOD2 0.00000000E+00
+C Step Time NOD1 TACS TACS TACS TACS TACS
+C OUT1 OUT2 OUT3 OUT4 OUT5
+C *** Phasor I(0) = 0.1000000E+03 Switch "NOD2 " to " " closed
+C 0 0.0 100. .015831432 .253238813 1.0 .001013202 .001013202
+C 1 .1E-3 99.950656 9.85825353 .353207504 1.0 .011010133 .011010133
+BLANK card ends selective node voltage outputs
+C Last step: 200 .02 100. .015828137 15.2109079 1.0 .001013198
+C Last step continued: .001013198 16.226736 16.2287624
+C Final 6 maxima : 15.2109079 1.0 .318280647 .318280647 55.0478571 54.6917329
+C Associated times : .02 0.0 .005 .005 .0181 .0181
+ PRINTER PLOT
+ 194 1. 0.0 10. TACS OUT7 { Axis limits: (-3.599, 4.883)
+BLANK card terminating plotting
+BEGIN NEW DATA CASE
+BLANK
+
|