diff --git a/benchmarks/dc49old.dat b/benchmarks/dc49old.dat new file mode 100644 index 0000000..525707f --- /dev/null +++ b/benchmarks/dc49old.dat @@ -0,0 +1,73 @@ +BEGIN NEW DATA CASE
+C BENCHMARK DC-49
+C Companion case to DC-32, which had MEMSAV=1 use. Development was first
+C documented in Volume X EMTP Memoranda, 3 July 1980, Pagination MSDO.
+C Node LOADA has a one-ohm resistor connected to FAULT, and this in turn
+C is connected to ground via switch number one. This fault switch was open
+C during DC-32, but will here be closed at 12 msec (the 1st step beyond
+C the backed-off switching time of 11.99 msec).
+$OPEN, UNIT=22 FILE=dc32to49.bin STATUS=OLD FORM=UNFORMATTED ! { (hold case)
+C $OPEN, UNIT=22 FILE=dc32.bin STATUS=OLD FORM=UNFORMATTED ! { (hold case)
+START AGAIN
+ 1 .011990
+ 9999
+$CLOSE, UNIT=22 STATUS=KEEP
+$OPEN, UNIT=22 STATUS=SCRATCH FORM=UNFORMATTED
+MISCELLANEOUS DATA CARDS
+ .000020 .018 .010
+ 1 1 0 0 1 0 0 2
+$OPEN, UNIT=4 FILE=dc32.pl4 STATUS=APPEND ! { C-like usage adds at end
+C The following step numbers are a continuation of DC-32, which simulated
+C 500 steps (DELTAT = 20 microseconds, TMAX = 10 milliseconds).
+CHANGE PRINTOUT FREQUENCY
+ 500 1 502 2 510 10 550 50
+C Step Time SECB SECA SECC AN4 AN5
+C CATH1 CATH2 CATH3 CATH4 CATH5
+C
+C AN6 AN5 AN4 CATH6 CATH5
+C
+C TRANC TRANB TRANA POLEB POLEA
+C
+C GENB GENC SECB SECA SECC
+C CATH1 CATH2 CATH3
+C TRANB TRANC
+C GENC GENA
+C 502 .01004 -211.3618 0.0 -239.0341 -46.136559 -300.6658
+C -141.67108 -141.67108 -141.67108 -67.862224 158.994718
+C -9.9160749 -77.285888 86.0849016 -141.67108 143.499575
+C -76.194786 -9.4236639 0.0 3.09902854 0.0
+C -.01815669 .012150754
+C Etc. (skip to next interesting event, which is the 1st switching):
+C Diode "SECA " to "CATH2 " opening after 1.02000000E-02 sec.
+C 510 .0102 -150.8714 0.0 -285.45775 -.45751033 -283.77559
+C -140.50318 -140.50318 -140.50318 -5.4593198 143.272405
+C -45.725494 -49.733993 97.8757247 -140.50318 145.412079
+C -48.641182 -45.235225 0.0 -.42793493 0.0
+C -.03153852 .006633174
+C Diode "AN4 " to "CATH4 " closing after 1.02200000E-02 sec.
+TIME STEP LOOP
+C Diode "SECC " to "CATH3 " opening after 1.72000000E-02 sec.
+C Diode "AN6 " to "CATH6 " opening after 1.72200000E-02 sec.
+C Diode "AN4 " to "CATH4 " closing after 1.77800000E-02 sec.
+C Diode "SECB " to "CATH1 " closing after 1.78400000E-02 sec.
+C 900 .018 0.0 0.0 -200.80168 0.0 -207.67249
+C -156.26361 -156.26361 -157.81916 105.964948 51.408884
+C -89.469147 18.0212454 73.9589646 -156.26361 41.4269674
+C 19.522284 -89.301354 12.9075961 1.99638332 0.0
+C -.00951582 -.00302247
+C Variable minima : -307.90065 -319.51502 -314.74562 -347.33303 -354.13903
+C -193.81352 -193.81352 -193.81352 -165.05691 -166.43183
+C -94.926015 -95.222122 -99.426568 -193.81352 38.4109479
+C -93.876407 -93.889586 -.89624956 -1.2792333 -.74181951
+C -.0346548 -.03640764
+C Times of minima : .00706 .00624 .00544 .0142 .015
+C .01488 .01488 .01488 .0146 .01626
+C .01564 .0148 .01646 .01488 .01726
+C .0173 .00312 .00372 .01552 .00216
+C .0177 .01604
+ PRINTER PLOT
+ 144 1. 10. 18. LOADA LOADB { Axis limits: (-2.784, 1.443)
+BLANK card ending plot cards
+BEGIN NEW DATA CASE
+BLANK
+
|