From b18347ffc9db9641e215995edea1c04c363b2bdf Mon Sep 17 00:00:00 2001 From: Angelo Rossi Date: Wed, 21 Jun 2023 12:04:16 +0000 Subject: Initial commit. --- benchmarks/dc49old.dat | 73 ++++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 73 insertions(+) create mode 100644 benchmarks/dc49old.dat (limited to 'benchmarks/dc49old.dat') diff --git a/benchmarks/dc49old.dat b/benchmarks/dc49old.dat new file mode 100644 index 0000000..525707f --- /dev/null +++ b/benchmarks/dc49old.dat @@ -0,0 +1,73 @@ +BEGIN NEW DATA CASE +C BENCHMARK DC-49 +C Companion case to DC-32, which had MEMSAV=1 use. Development was first +C documented in Volume X EMTP Memoranda, 3 July 1980, Pagination MSDO. +C Node LOADA has a one-ohm resistor connected to FAULT, and this in turn +C is connected to ground via switch number one. This fault switch was open +C during DC-32, but will here be closed at 12 msec (the 1st step beyond +C the backed-off switching time of 11.99 msec). +$OPEN, UNIT=22 FILE=dc32to49.bin STATUS=OLD FORM=UNFORMATTED ! { (hold case) +C $OPEN, UNIT=22 FILE=dc32.bin STATUS=OLD FORM=UNFORMATTED ! { (hold case) +START AGAIN + 1 .011990 + 9999 +$CLOSE, UNIT=22 STATUS=KEEP +$OPEN, UNIT=22 STATUS=SCRATCH FORM=UNFORMATTED +MISCELLANEOUS DATA CARDS + .000020 .018 .010 + 1 1 0 0 1 0 0 2 +$OPEN, UNIT=4 FILE=dc32.pl4 STATUS=APPEND ! { C-like usage adds at end +C The following step numbers are a continuation of DC-32, which simulated +C 500 steps (DELTAT = 20 microseconds, TMAX = 10 milliseconds). +CHANGE PRINTOUT FREQUENCY + 500 1 502 2 510 10 550 50 +C Step Time SECB SECA SECC AN4 AN5 +C CATH1 CATH2 CATH3 CATH4 CATH5 +C +C AN6 AN5 AN4 CATH6 CATH5 +C +C TRANC TRANB TRANA POLEB POLEA +C +C GENB GENC SECB SECA SECC +C CATH1 CATH2 CATH3 +C TRANB TRANC +C GENC GENA +C 502 .01004 -211.3618 0.0 -239.0341 -46.136559 -300.6658 +C -141.67108 -141.67108 -141.67108 -67.862224 158.994718 +C -9.9160749 -77.285888 86.0849016 -141.67108 143.499575 +C -76.194786 -9.4236639 0.0 3.09902854 0.0 +C -.01815669 .012150754 +C Etc. (skip to next interesting event, which is the 1st switching): +C Diode "SECA " to "CATH2 " opening after 1.02000000E-02 sec. +C 510 .0102 -150.8714 0.0 -285.45775 -.45751033 -283.77559 +C -140.50318 -140.50318 -140.50318 -5.4593198 143.272405 +C -45.725494 -49.733993 97.8757247 -140.50318 145.412079 +C -48.641182 -45.235225 0.0 -.42793493 0.0 +C -.03153852 .006633174 +C Diode "AN4 " to "CATH4 " closing after 1.02200000E-02 sec. +TIME STEP LOOP +C Diode "SECC " to "CATH3 " opening after 1.72000000E-02 sec. +C Diode "AN6 " to "CATH6 " opening after 1.72200000E-02 sec. +C Diode "AN4 " to "CATH4 " closing after 1.77800000E-02 sec. +C Diode "SECB " to "CATH1 " closing after 1.78400000E-02 sec. +C 900 .018 0.0 0.0 -200.80168 0.0 -207.67249 +C -156.26361 -156.26361 -157.81916 105.964948 51.408884 +C -89.469147 18.0212454 73.9589646 -156.26361 41.4269674 +C 19.522284 -89.301354 12.9075961 1.99638332 0.0 +C -.00951582 -.00302247 +C Variable minima : -307.90065 -319.51502 -314.74562 -347.33303 -354.13903 +C -193.81352 -193.81352 -193.81352 -165.05691 -166.43183 +C -94.926015 -95.222122 -99.426568 -193.81352 38.4109479 +C -93.876407 -93.889586 -.89624956 -1.2792333 -.74181951 +C -.0346548 -.03640764 +C Times of minima : .00706 .00624 .00544 .0142 .015 +C .01488 .01488 .01488 .0146 .01626 +C .01564 .0148 .01646 .01488 .01726 +C .0173 .00312 .00372 .01552 .00216 +C .0177 .01604 + PRINTER PLOT + 144 1. 10. 18. LOADA LOADB { Axis limits: (-2.784, 1.443) +BLANK card ending plot cards +BEGIN NEW DATA CASE +BLANK + -- cgit v1.2.3