BEGIN NEW DATA CASE
C BENCHMARK DCPR-1
C Test of 1-phase constant-parameter line. One switch is permanently
C closed. No transients. Plot of receiving end voltage is sinusoid.
DIAGNOSTIC 0 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9
PRINTED NUMBER WIDTH, 13, 2, { Request maximum precision (for 8 output columns)
.000100 .020 60. 60.
1 1 1 1 1 -1
2 -1 5 5 20 20
REC .001 { Near short at receiving end to ground } 3
-1SEND REC 0.3 0.4 12.6 100. { 1-phase distributed line
BLANK card ending branch cards
GEN SEND -1.0 1.0 { Permanently closed switch at sending end
BLANK card ending switch cards
14GEN 100. 60. { 60-Hz phasor solution } -1.
BLANK card ending source cards
C Total network loss P-loss by summing injections = 5.992836086590E+01
C GEN
C SEND 100. 100. 1.1985672173179 1.9672525544427
C 0.0 0.0 -1.559974114699 -52.4640241
C Step Time REC REC SEND GEN REC
C TERRA TERRA
C 0 0.0 .001198266 .001198266 100. 100. 1.198266
C 1 .1E-3 .0012585558 .0012585558 99.92894726 99.92894726 1.258555833
1
C 200 .02 .0019138946 .0019138946 30.90169944 30.90169944 1.913894577
C Variable max : .0020173699 .0020173699 100. 100. 2.017369917
C Times of max : .0025 .0025 0.0 0.0 .0025
C Variable min : -.002017453 -.002017453 -99.9921044 -99.9921044 -2.01745286
C Times of min : .0108 .0108 .0083 .0083 .0108
PRINTER PLOT
194 4. 0.0 20. REC { Axis limits : (-2.017, 2.017)
BLANK card ending plot cards
BEGIN NEW DATA CASE
C 2nd subcase involves use of trapped-charge source to initialize
C an initially-disconnected single-phase line. Later, energize the
C line by switch closure at 3 msec. The data was supplied by Dipl.
C Ing. Bernd Stein of FGH (Mannheim, Germany) during April of 1986.
PRINTED NUMBER WIDTH, 13, 2, { Request maximum precision (for 8 output columns)
DIAGNOSTIC 0 9 0 9 9 9 0 9 9 9 0 9 9 9 9 9 9 9 9
ALTERNATE DIAGNOSTIC PRINTOUT, 0, 0, 0, 0, { Need for 2nd or later subcase only
.000100 .020 { Unlike 1st of 2 subcases, here XOPT = COPT = 0
1 1 0 1 1 -1
2 -1 5 5 20 20 { Switch to alternate on step 2
GEN SWITCH 39.8
SWITCH 1000.
-1SEND REC .3055 5.819 .0121 138.
BLANK card ending branch cards
SEND SWITCH .003 1.0 { Transient begins at 3 msec with closure
BLANK card ending switch cards
C 1 2 3 4 5 6 7 8
C 78901234567890123456789012345678901234567890123456789012345678901234567890
14GEN 100. 60. -1.0
14SEND -1 -100. .001 { Trapped-charge source } 5432.
C End multiple-frequency phasor solution data. The first source is a regular
C 60-Hertz generator, whereas the second has f = 1/1000 Hz for trapped charge
BLANK card ending source cards
C Total network loss P-loss by summing injections = 4.998874616296E+00
C Last gen: SEND -100. 100. -.17408297E-12 .10491662826E-5 .8704148513E-11
C Last gen: 0.0 180.0 -.1049166283E-5 -90.0000095 -.5245831413E-4
C Step Time REC SEND SWITCH GEN
C 0 0.0 -100. -100. 99.97749233 100.
C 1 .1E-3 -100. -100. 99.96299489 99.92894726
C 2 .2E-3 -100. -100. 99.80645119 99.71589003
1 { Request for the output of all four node voltages
C 200 .02 138.2909745 45.09406184 45.09406184 30.90169944
144 2. 0.0 20. SEND REC { Axis limits : (-2.510, 2.052)
BLANK card ending plot cards
BEGIN NEW DATA CASE
BLANK
|