summaryrefslogtreecommitdiffstats
path: root/benchmarks/dc35.dat
blob: 37c3fe035f19a0beecac307f76ac7147850676df (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
BEGIN NEW DATA CASE
C     BENCHMARK DC-35
C     U.M. test consisting of 3-phase induction motor startup.  See Vol. X  EMTP
C     Memoranda, 15 April 1980,  page TPIM-6 onward.   TMAX  has been decreased,
C     DELTAT  has been increased,  and  resistors shorting the rotor  have  been
C     increased (to help lower-precision computers).  Also appears in Rule Book.
PRINTED NUMBER WIDTH, 12, 2,  { Request maximum precision (for 8 output columns)
 .000400    .400
       1       1       0      00       1      -1       0
       5       5      20      20     100     100
C                       The following 3 branches provide connectivity to ground:
 0      BUS-A0            1.0
 0      BUS-B0            1.0
 0      BUS-C0            1.0
C             Next comes the source impedance, as uncoupled series R-L branches:
 0BUS-A1BUS-A0            0.005 1.0                                            2
 0BUS-B1BUS-B0BUS-A1BUS-A0                                                     2
 0BUS-C1BUS-C0BUS-A1BUS-A0                                                     2
C         Next there is a near short of the rotor windings (squirrel cage case):
 0BUSRA1                   1.E-5
 0BUSRB1                   1.E-5
 0BUSRC1                   1.E-5
C      Final branches are for rotor mass (capacitance) and damping (resistance):
 0BUS-OM                              6.00E4
 0      BUS-OM            33.333                                               1
BLANK card terminating branch cards
BLANK card ends non-existent switch cards
14BUS-A0  180.0      60.0     0.0
14BUS-B0  180.0      60.0     -120.0
14BUS-C0  180.0      60.0     +120.0
11BUS-OM-1 -6.00
19 UM              { 1st of U.M. data cards to represent 3-phase induction motor
0
BLANK card ending Class-1 U.M. data
 4 1 1111BUS-OM       2 0.06                       0.18850   { 1st machine table
0.0           0.020291      0
0.0           0.020291      0
0.063         0.0001911     BUS-A1            1 0.0           { 1st winding card
0.063         0.0003925     BUS-B1            1 0.0
0.063         0.0003925     BUS-C1            1 0.0
0.083         0.0003925     BUSRB1            1 0.0
0.083         0.0003925     BUSRC1            1 0.0
0.083         0.0003925     BUSRA1            1 0.0
BLANK card ending all U.M. data
BLANK card ending electric network source cards
  BUS-A1BUS-B1BUS-C1BUS-A0BUS-OM
C   Step      Time       BUS-A1      BUS-B1      BUS-C1      BUS-A1       BUS-B1
C                        BUS-A0      BUS-B0      BUS-C0
C
C                        UM-1        UM-1        UM-1        UM-1           UM-1
C                        TQGEN       OMEGM       THETAM      IPA             IPB
C      0       0.0          0.0         0.0         0.0         0.0          0.0
C                           0.0         0.0         0.0         0.0          0.0
C      1     .4E-3   -98.574299  36.3155088  62.2587899  79.3830153   -29.245296
C                    -.1388E-16         0.0         0.0  -19.695165   7.25584591
C      2     .8E-3   -92.178447  20.8386935  71.3397538  79.6971707   -18.794915
C                    -.00570624         0.0         0.0   -57.76825   18.6607698
BLANK card ends requests for program output
C Last step begins:  1000   0.4   -8.3684481  1.39626098  6.97218715  171.631552
C Last step begins:   -12.310167  187.573334  46.3605875  -8.8049393   23.504665
C Maxima begin:       99.6139318   106.19115  100.446912  171.631552  171.624746
C Maxima begin:       144.878041  197.090289  46.3605875    302.2867  263.869636
C Associated times :       .0912       .0132       .0356         0.4       .3556
C Associated times :       .0388       .2492         0.4       .1284       .1508
C Minima begin:       -103.15511  -99.851577  -103.80211  -171.82882  -171.84501
C Minima begin:       -186.32292  -.41620944  -.58668E-3  -299.62596  -384.19564
C Associated times :        .016       .0716       .0104       .3584        .364
C Associated times :       .0116       .0028       .0052       .0368       .0088
C     78901234567890123456789012345678901234567890123456789012345678901234567890
 193.04 0.0 .40         UM-1  OMEGM             Induction motor w in [rad/sec]
  PRINTER PLOT    { Now switch to the line printer  (exactly the same plot card)
 193.04 0.0 .40         UM-1  OMEGM              { Axis limits: (-0.004,  1.971)
 2Single-line, 78-character case title text !
  First of 2 lines of multi-line, 78-byte, subheading text. !
  Second and final line of multi-line labeling text.        !
  CALCOMP PLOT
 193.04 0.0 .40         UM-1  IPA
  PEN PLOT              { Divert vector graphics from screen to disk for printer
  QUARTER PLOT   { Blank col 32 means all 4 quarters of quarter plotting is used
 2Single-line case-title text for 1st of 4 quarters!
 193.04 0.0 .40         UM-1  OMEGM             1st of 4 quarterw in [rad/sec] !
 2Single-line case-title text for 2nd of 4 quarters!
 193.04 0.0 .40         UM-1  THETAM            2nd of 4 quarterAngle in radian!
 2Single-line case-title text for 3rd of 4 quarters!
 193.04 0.0 .40         UM-1  TQGEN             3rd of 4 quarterTorque in n-m  !
 2Single-line case-title text for 4th of 4 quarters!
 193.04 0.0 .40         UM-1  IPA               4th of 4 quarterCurrent in amp !
  SCREEN PLOT
 2Done with QUARTER PLOT;  back to full size!
 193.04 0.0 .40         UM-1  IPB
BLANK card ends the last plot card
BEGIN NEW DATA CASE
BLANK



BEGIN NEW DATA CASE
C     2nd of 2 subcases has the same data as the 1st,  but is used to illustrate
C     CALCOMP PLOT  usage only.   Both  SCREEN PLOT  and  PEN PLOT  usage of the
C     Salford  DOS  extender motivated  the addition of this data in Sept, 1990.
PRINTED NUMBER WIDTH, 12, 2,  { Request maximum precision (for 8 output columns)
 .000400    .040      { Note the reduction from 1000 to 100 time steps for speed
       1       1       0      00       0      -1       0
       5       5      20      20    
C                       The following 3 branches provide connectivity to ground:
 0      BUS-A0            1.0
 0      BUS-B0            1.0
 0      BUS-C0            1.0
C             Next comes the source impedance, as uncoupled series R-L branches:
 0BUS-A1BUS-A0            0.005 1.0                                            2
 0BUS-B1BUS-B0BUS-A1BUS-A0                                                     2
 0BUS-C1BUS-C0BUS-A1BUS-A0                                                     2
C         Next there is a near short of the rotor windings (squirrel cage case):
 0BUSRA1                   1.E-5
 0BUSRB1                   1.E-5
 0BUSRC1                   1.E-5
C      Final branches are for rotor mass (capacitance) and damping (resistance):
 0BUS-OM                              6.00E4
 0      BUS-OM            33.333                                               1
BLANK card terminating branch cards
BLANK card ends non-existent switch cards
14BUS-A0  180.0      60.0     0.0
14BUS-B0  180.0      60.0     -120.0
14BUS-C0  180.0      60.0     +120.0
11BUS-OM-1 -6.00
19 UM              { 1st of U.M. data cards to represent 3-phase induction motor
0
BLANK card ending Class-1 U.M. data
 4 1 1111BUS-OM       2 0.06                       0.18850   { 1st machine table
0.0           0.020291      0
0.0           0.020291      0
0.063         0.0001911     BUS-A1            1 0.0           { 1st winding card
0.063         0.0003925     BUS-B1            1 0.0
0.063         0.0003925     BUS-C1            1 0.0
0.083         0.0003925     BUSRB1            1 0.0
0.083         0.0003925     BUSRC1            1 0.0
0.083         0.0003925     BUSRA1            1 0.0
BLANK card ending all U.M. data
BLANK card ending electric network source cards
  BUS-A1BUS-B1BUS-C1BUS-A0BUS-OM
BLANK card ends requests for program output
 2Single-line, 78-character case title text !
  First of 2 lines of multi-line, 78-byte, subheading text. !
  Second and final line of multi-line labeling text.        !
 194 4. 0.0 40.         UM-1  OMEGM             Induction motor w in [rad/sec] !
  PEN PLOT       { Now switch to the Epson printer  (exactly the same plot card)
 2Single-line, 78-character case title text !
  First of 2 lines of multi-line, 78-byte, subheading text. !
  Second and final line of multi-line labeling text.        !
 194 4. 0.0 40.         UM-1  OMEGM             Induction motor w in [rad/sec] !
  SCREEN PLOT
  First of 2 lines ---  text is altered, though. !
  Second   2 lines ---  text is altered.         !
 194 4. 0.0 40.         UM-1  OMEGM             Induction motor w in [rad/sec] !
BLANK card ends the last plot card
BEGIN NEW DATA CASE
BLANK