1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
|
BEGIN NEW DATA CASE
C BENCHMARK DC-32
C Artificial 6-pulse dc power supply that illustrates the simulation of
C diodes. It was concocted in July of 1977 to instruct Hughes Aircraft in
C Fullerton, California (Emory Johnson, Gene Perusse, and assoc.). Use of
C MEMSAV = 1 dumps tables for later restarting and modification (see DC-49).
C It is assumed that STARTUP has KTRPL4 < 0 and L4BYTE = 1 so that a
C C-like ".PL4" file having name DC32.PL4 will be created (used by DC-49).
PRINTED NUMBER WIDTH, 12, 2, { Request maximum precision (for 8 output columns)
.000020 .010
1 1 1 1 1 -1 1 2
5 5 10 10 50 50
C Three 2-winding saturable transformers having unity turns ratios are
C delta-connected on the source side, and grounded-Y on the rectifier
C side. The magnetizing branch is both nonlinear and lossy:
TRANSFORMER .01 .05TRANA 1.E5 1
.01 .05
.02 .06
.05 .07
.15 .08
9999
1GENA GENB .06 .01 115.
2SECA .06 .01 115.
TRANSFORMER TRANA TRANB 1
1GENB GENC
2SECB
TRANSFORMER TRANA TRANC 1
1GENC GENA
2SECC
C Small impedance branches are used (prior to "M34." generalized switch
C logic) to isolate switches from each other at "POLEA". R = 5 ohms.
C Although in theory such isolation is no longer required, do not try
C to remove these 9 resistors, since they provide necessary damping.
C Note that these resistors are not of negligible value:
CATH1 POLEA 5.0
CATH2 POLEA CATH1 POLEA
CATH3 POLEA CATH1 POLEA
C More small impedances used for switch isolation at node "POLEB", and
C also at the transformer secondary. Half the value of "POLEA" is used,
C for balance:
CATH4 SECC 2.5
CATH5 SECA CATH4 SECC
CATH6 SECB CATH4 SECC
AN4 POLEB CATH4 SECC
AN5 POLEB CATH4 SECC
AN6 POLEB CATH4 SECC
C 2-conductor distributed line connects "POLE" with "LOAD". Inductance
C parameters are 5.8 and 1.6 millihenries for the ground and sky modes,
C respectively. Length is five miles. Values are typical for 500 kV line:
-1POLEA LOADA 0.3 5.8 .012 5.0
-2POLEB LOADB .03 1.6 .019 5.0
C Large stray capacitance ties the dc side to ground:
POLEA 100.
POLEB POLEA
C Load on dc side is parallel 200 ohm R and 100 microfarad capacitance:
LOADA LOADB 200.
LOADA LOADB 100.
C One-ohm grounding resistance, for later fault (see DC-49 continuation).
LOADA FAULT 1.0
BLANK card ending all branch cards
C First switch is to be the fault switch (open here, and closed in DC-49):
FAULT 1.0 2.0
C Bridge circuit consisting of 6 uncontrolled valves (i.e., diodes). Those
C numbered 1, 2, and 3 feed "POLEA", making it positive with respect to
C ground. Diodes 4, 5, and 6 feed "POLEB", making it negative.
11SECB CATH1 13
11SECA CATH2 CLOSED 13
C The following card serves to name the switch following it. To see the
C results of this activity, interactively execute the "SWITCH" command of
C SPY, sending "EXTRA" for the alternative table. Another point: note
C the exclamation point, which is needed to hold lower case within A6 name
C (assuming KINSEN = 1 within STARTUP). No such control for valve six.
NAME: Valve3 ! { Request "NAME: " of cols. 3-8 precedes A6 valve name in 9-14
11SECC CATH3 13
11AN4 CATH4 CLOSED 13
11AN5 CATH5 13
NAME: Valve6 { Request "NAME: " of columns 3-8 precedes A6 valve name in 9-14
11AN6 CATH6 CLOSED 13
BLANK card terminating the last switch card
C Balanced 3-phase source of 400 Hz is connected to transformer delta side:
14GENA 93.897 400. -30. -1.
14GENB 93.897 400. -150. -1.
14GENC 93.897 400. 90. -1.
C --------------+------------------------------
C From bus name | Names of all adjacent busses.
C --------------+------------------------------
C TRANA |GENA *GENB *GENB *GENB *
C GENA |TRANA *TRANC *TRANC *TRANC *
C GENB |TRANA *TRANA *TRANA *TRANB *
C SECA |TERRA *CATH2 *CATH5 *
C TRANB |GENB *GENC *GENC *GENC *
C GENC |TRANB *TRANB *TRANB *TRANC *
C SECB |TERRA *CATH1 *CATH6 *
C TRANC |GENA *GENA *GENA *GENC *
C SECC |TERRA *CATH3 *CATH4 *
C CATH1 |SECB *POLEA *
BLANK card ending all source cards
C Total network loss P-loss by summing injections = 5.464331532263E+03
C Last inject: GENC .5749502208E-14 93.897 .56200164704342 55.017880322583
C Last inject: 93.897 90.00000 55.015009854937 89.4147197
C ---- Initial flux in coil "TRANA " to "GENB " = -5.34394317E-04
C ---- Initial flux of coil "TRANB " to "GENC " = -5.51987844E-02
C ---- Initial flux of coil "TRANC " to "GENA " = 5.55634966E-02
C Step Time SECB SECA SECC AN4 AN5
C CATH1 CATH2 CATH3 CATH4 CATH5
C
C AN6 AN5 AN4 CATH6 CATH5
C
C TRANC TRANB TRANA POLEB POLEA
C
C GENB GENC SECB SECA SECC
C CATH1 CATH2 CATH3
C TRANB TRANC
C GENC GENA
C *** Phasor I(0) = 1.6873295E+01 Switch "SECA " to "CATH2 " closed
C *** Phasor I(0) = 2.4078446E+00 Switch "AN4 " to "CATH4 " closed
C *** Phasor I(0) = 2.9476803E+00 Switch "AN6 " to "CATH6 " closed
C 0 0.0 -159.68633 0.0 -156.98715 0.0 -229.3144
C -75.303917 -67.934716 -73.954328 -75.303917 161.379687
C .671413046 -81.994732 80.6896357 -67.934716 77.0132094
C -81.317187 .57495E-14 0.0 16.8732954 0.0
C -.01344725 .013015515
C 1 .2E-4 -156.60201 0.0 -167.73205 0.0 -230.84408
C -72.617115 -69.533258 -78.182135 -72.617115 161.310826
C -3.989552 -79.633884 83.0140826 -69.533258 80.9010357
C -78.855585 -4.7177907 0.0 16.0819581 0.0
C -.01676789 .01388141
C Diode "AN6 " to "CATH6 " opening after 4.00000000E-05 sec.
C Note: LUNIT2 = 22 and lower-case ".bin" (maintained by exclamation point)
C are critical details of the following connection of file for tables:
C $OPEN, UNIT=22 FILE=dc32to49.bin ! { All we need for C-like usage by Salford
$OPEN, UNIT=22 FILE=dc32to49.bin STATUS=NEW FORM=UNFORMATTED !
1 { Request for all node voltage outputs
C Last step: 501 .01002 -214.9097 0.0 -230.24759 -54.516468 -303.96907
C Last step: -141.81435 -141.81435 -141.81435 -71.959981 162.154725 -87.297878
C Last step: -4.2249272 -77.760947 83.4315479 -141.81435 142.949714 -87.297878
C Last step: -78.855585 -4.7177907 0.0 3.84100209 0.0 0.0
C Last step: -.01674763 .013984083
C Variable maxima : 6.75796709 10.2225472 7.99663598 5.4523958 4.41773517
C -55.736451 -57.621411 -60.99918 162.583272 162.349471
C 94.2715412 94.2204174 94.5734275 -57.621411 157.838356
C 93.8961762 93.8895863 15.8739724 19.1582929 16.8070015
C .036546956 .033001353
C Times of maxima : .0081 .00206 .00894 .00526 .00334
C .00258 .00262 .00186 .00584 .005
C .00938 .00854 .00522 .00262 .006
C .00354 .00938 .00326 .00244 .00166
C .00646 .0098
C Variable minima : -307.90065 -319.51502 -314.74562 -314.64493 -305.0677
C -157.13852 -159.69143 -157.2627 -154.31324 -159.94136
C -94.501887 -94.313812 -94.506969 -157.13852 55.660011
C -93.876407 -93.889586 -.89624956 -.45248549 -.74181951
C -.03163582 -.03508457
C Times of minima : .00706 .00624 .00544 .00666 .00502
C .006 .00624 .00546 .0071 .00616
C .00564 .0048 .00646 .006 .00224
C .0098 .00312 .00372 .34E-3 .00216
C .2E-3 .00604
PRINTER PLOT
144 1. 0.0 10. LOADA LOADB { Axis limits: (-1.637, 1.618)
$WIDTH, 79, { Narrow output width will save paper from here on (summary stats)
BLANK card ending the last plot cards
BEGIN NEW DATA CASE
BLANK
|