1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
|
BEGIN NEW DATA CASE
C BENCHMARK DC-31
C Simulation of single-line-to-ground-fault on the open receiving end of the
C single-circuit, 138-mile, 500-kV overhead line that connects "John Day"
C with "lower monumental" (BPA substations). Semlyen representation from
C DC-29 is used for the line. See DCNEW-4 for the corresponding Marti
C simulation. See Rule Book Ref. 3 for further description. Yet observe
C that source angles and the instant of fault initiation do not correspond.
C There are a total of 3 subcases, with two following unrelated to this
PRINTED NUMBER WIDTH, 13, 2, { Request maximum precision (for 8 output columns)
.000050 .050 60. 60.
1 1 1 1 1 -1
5 5 20 20 100 100
JDGA JDA 14. 1
JDGB JDB 14.
JDGC JDC 14.
C L= 138.0MILES, RHO= 27.0, SS FREQ= 60.00, NSS=0, KFIT= 0, KPS=2, KYC=10
C 1.3636 .05215 4 1.602 -20.75 50. 50.
C 1.3636 .05215 4 1.602 -19.25 50. 50.
C 2.3636 .05215 4 1.602 - 0.75 77.5 77.5
C 2.3636 .05215 4 1.602 0.75 77.5 77.5
C 3.3636 .05215 4 1.602 19.25 50. 50.
C 3.3636 .05215 4 1.602 20.75 50. 50.
C 0.5 2.61 4 0.386 -12.9 98.5 98.5
C 0.5 2.61 4 0.386 12.9 98.5 98.5
C
C 27. 5000. 1 138.
C 27. 60.00 1 138.
C 27. 6.00 1 138. 6 20
C
-1JDA LMA 0.55456E-02 0.77998E-03 1 1 2 2 3
0.14938602E+02 0.90516313E+02-0.16261865E-03 0.14500324E-02 0.60000000E+02
0.00000E+00 0.15161E+05 0.75119E+00 0.00000E+00 0.17105E+04 0.24881E+00
0.00000E+00 0.59584E+03-0.11954E-02 0.00000E+00 0.39933E+05-0.74162E-03
-1JDB LMB 0.74392E-02 0.74149E-03 2 2 2 2 3
0.83801231E+00 0.38634735E+02-0.44536501E-04 0.20637999E-02 0.60000000E+02
0.00000E+00 0.26608E+06 0.83767E+00 0.00000E+00 0.35627E+05 0.16233E+00
0.00000E+00 0.13630E+03-0.49171E-03 0.00000E+00 0.32940E+05-0.75349E-04
-1JDC LMC 0.42823E-02 0.74017E-03 3 3 2 2 3
0.26535168E+01 0.67894100E+02-0.45225808E-04 0.11682248E-02 0.60000000E+02
0.00000E+00 0.61698E+06 0.90903E+00 0.00000E+00 0.15239E+05 0.90969E-01
0.00000E+00 0.25667E+03-0.34465E-03 0.00000E+00 0.11831E+05-0.28233E-04
0.10000E+01 0.00000E+00 0.10000E+01 0.00000E+00-0.26698E+00 0.00000E+00
0.71114E+00 0.00000E+00-0.41983E-15 0.00000E+00 0.10000E+01 0.00000E+00
0.10000E+01 0.00000E+00-0.10000E+01 0.00000E+00-0.26698E+00 0.00000E+00
0.42027E+00 0.00000E+00 0.50000E+00 0.00000E+00-0.29908E+00 0.00000E+00
0.22471E+00 0.00000E+00-0.27373E-15 0.00000E+00 0.84054E+00 0.00000E+00
0.42027E+00 0.00000E+00-0.50000E+00 0.00000E+00-0.29908E+00 0.00000E+00
C Note: the preceding branch cards are old. If produced by SEMLYEN SETUP
C on or after 27 November 2000, the low precision [Tv] and [Ti] would
C be replaced by high precision for the real parts only. This can be
C seen from current output of DC-29. 6E12.5 ---> 3E26.18 We retain
C the old branch cards in this subcase to demonstrate that such old data
C continues to remain compatible. See NO IMAGINARY PART as is being
C written about for the April, 2001, newsletter. To see use of the new
C wide format for [Tv] and [Ti], see DC-62.
TOWER 2.0
BLANK card ending branch cards
LMA TOWER .00433 1.0 1
BLANK card terminating all switch cards
14JDGA 303000. 60. -90. -1.
14JDGB 303000. 60. -210. -1.
14JDGC 303000. 60. 30. -1.
BLANK card ending all source cards
C Total network loss P-loss by summing injections = -4.779046825640E+06
C Last inject: JDGC 262405.69734669 303000. -173.5167762169 331.67972792735
C Last inject: 151500. 30.0000 282.67184205232 121.5434868
LMA LMB LMC JDA JDC
C Step Time LMA LMB LMC JDA JDC
C
C 0 0.0 1571.475581 -276456.932 278765.7622 153.7361338 266363.1031
C 1 .5E-4 7630.423588 -279401.215 275709.5695 5941.026761 263392.9685
C 2 .1E-3 13684.53899 -282253.973 272563.1515 11741.29345 260360.8975
C 3 .15E-3 19733.66162 -285005.65 269320.0035 17534.50579 257232.6923
BLANK card ending output variable requests
C Last step begins: 1000 .05 -4383.86263 -267262.886 294635.7149
C Last step continue ..... : -3765.02773 266358.2578 -2191.93132 -2002.40336
C Variable max : 321290.8039 382325.3516 420199.3815 307502.4578 313056.9229
C Times of max : .00415 .0271 .015 .00415 .01555
C Variable min : -4633.97345 -375865.379 -529913.225 -303202.542 -357915.083
C Times of min : .01665 .01825 .0061 .01245 .00685
PRINTER PLOT { Axis limits: (-5.299, 4.202)
2Simulation of fault at Lower Monumental end of 138-mile line to John Day.
1 SMOOTH
PRINT HEAD OFF
Voltage at Lower Monumental, where "a"-phase is faulted at 4.33 msec.
144 2. 0.0 20. LMA LMB LMC Lower Mon. Fault voltage in volt
BLANK card ending all plot cards
BEGIN NEW DATA CASE
C 2nd of 3 data subcases is unrelated to the 1st. 3rd will be compared with it
C 1973 GPU Stolle Road to Homer City line energization without surge arresters
C These extra two cases are added to document Prof. Xusheng Chen's transformer
C as described in January, 1993, newsletter.
.000050 .050 60. 60. { Increase deltat from 25 microsecs of '70s
100 1 0 0 1
SORA GARA 3.06
SORB GARB 3.06
SORC GARC 3.06
-1GARA ST1A .6109 2.3280 3.02 12.44
-2GARB ST1B .1278 .79260 5.36 12.44
-3GARC ST1C
1GARA ERIA 6.2245
2GARB ERIB 2.4289 6.2245
3GARC ERIC 2.4289 2.4289 6.2245
1GARA DAVA 21.905
2GARB DAVB 10.465 21.905
3GARC DAVC 10.465 10.465 21.905
-1ERIA ST1A .6701 2.3608 3.02 10.70
-2ERIB ST1B .1000 .71960 5.36 10.70
-3ERIC ST1C
-1ROLA ST1A .6342 2.3507 3.02 20.27
-2ROLB ST1B .1005 .72150 5.36 20.27
-3ROLC ST1C
-1DAVA ST1A .6641 2.3641 3.02 14.53
-2DAVB ST1B .0998 .71990 5.36 14.53
-3DAVC ST1C
TRANSFORMER 21.3 249.1TRANA 1
21.3 249.1
99.8 274.0
236.9 288.9
1602. 326.3
9999.
1SWPA 0.0 -1.11 115.
2ST3A 0.0 39.4 345.
3T-A T-B 0.0 1.24 59.75
TRANSFORMER TRANA TRANB 1
1SWPB
2ST3B
3T-B
TRANSFORMER TRANA TRANC 1
1SWPC
2ST3C
3 T-A
-1ST3A HOMA .6129 1.9245 4.50 214.0
-2ST3B HOMB .0502 .59410 7.05 214.0
-3ST3C HOMC
ST3A 96514. 1930.
ST3B 96514. 1930.
ST3C 96514. 1930.
ST3A 12.82
ST3B 12.82
ST3C 12.82
SWPA 37.70
SWPB 37.70
SWPC 37.70
C 24 July 2008, add a disconnected Type-51, 52 branch that has very low
C impedance. The [R] and [L] matrices are perfectly invertible; in fact, for
C simplicity, we make them diagonal. Prior to improvement of REDUCT, the
C ATP response was to halt execution. The small numbers made ATP think that
C the matrix was singular. A 40-year-old weakness was just noticed (amazing):
C ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ ...
C KILL code number Overlay number Nearby statement number
C 86 13 4233
C KILL = 86. Singularity has been detected within SUBROUTINE REDUCT ...
51SORA 1.E-19 1.E-19 { R(1,1) = L(1,1) = 1.E-19
52EXTRA 0.0 0.01.E-19 1.E-19 { R(2,1) = L(2,1) = 0
EXTRA 1.0 { Let the secondary drive a 1-ohm resistor
BLANK card ending all branch cards
ST1A SWPA .007940 1.0
ST1B SWPB .007940 1.0
ST1C SWPC .007940 1.0
BLANK card ending all switch cards
14SORA 93800. 60. 185. -1.0
14SORB 93800. 60. 65. -1.0
14SORC 93800. 60. -55. -1.0
C Total network loss P-loss by summing injections = 2.199610000000E+28
C This extraordinary phasor loss is due to that extra Type-51, 52 branch,
C which is nearly a short circuit. Without it, loss is 4.805637702155E+02
BLANK card ending all source cards
SWPA SWPB SWPC ST3A ST3B ST3C HOMA HOMB HOMC SWPA SWPB SWPC
C Step Time SWPA SWPB SWPC ST3A ST3B
C
C HOMC SWPA SWPB SWPC TRANA
C TERRA
C 0 0.0 0.0 0.0 0.0 0.0 0.0
C 0.0 0.0 0.0 0.0 0.0
C 100 .005 0.0 0.0 0.0 0.0 0.0
C 0.0 0.0 0.0 0.0 0.0
C *** Close switch "ST1A " to "SWPA " after 7.95000000E-03 sec.
C *** Close switch "ST1B " to "SWPB " after 7.95000000E-03 sec.
C *** Close switch "ST1C " to "SWPC " after 7.95000000E-03 sec.
C 200 .01 74055.64255 1496.684511 -75552.3271 217501.3182 -11199.8796
C -202295.843 74055.64255 1496.684511 -75552.3271 11.60842824
BLANK card ending selective node voltage output requests
C 1000 .05 -41438.1417 14616.52552 4941.023887 -74849.3547 24242.7193
C -300362.665 -41438.1417 14616.52552 4941.023887 -.003640141
C Variable max : 169590.981 140542.9342 130439.2455 610291.9724 509791.1645
C 761896.4358 169590.981 140542.9342 130439.2455 1615.403803
C Times of max : .04255 .02965 .03775 .0425 .02945
C .03865 .04255 .02965 .03775 .02875
C Variable min : -156192.014 -132716.009 -161788.345 -534753.351 -467406.362
C -777439.086 -156192.014 -132716.009 -161788.345 -43.1002572
C Times of min : .016 .04015 .04285 .0161 .04065
C .0427 .016 .04015 .04285 .03875
PRINTER PLOT
144 5. 0.0 50. HOMA { Axis limits: (-7.642, 8.522)
BLANK card ending plot cards
BEGIN NEW DATA CASE
C 3rd of 3 data subcases is the same as the 2nd except for 3-phase transformer
C 1973 GPU Stolle Road to Homer City line energization without surge arresters
C These extra two cases are added to document Prof. Xusheng Chen's transformer
C as described in the January and April, 1993, issues of the newsletter. The
C case came from Prof. Chen as disk file MDD6A.DAT on a floppy dated May 20,
C 1993 (this replaces the original 3rd subcase that was created 31 Mar 1993)
C July, 1995, Prof. Chen replaces his XFCHEN, and answers change. The
C old data case will be copied below as comments of this one are updated.
PRINTED NUMBER WIDTH, 11, 1, { Request default precision (cancel [13,2] of 1st)
C 4 May 2007, add following $PREFIX to allow remote execution.
C Without this, the following DC31CHEN.DAT would not be found.
$PREFIX, [] { $INCLUDE files are located in same place as this main data file
USE SEATTLE XFORMER, dc31chen.dat ! { (hold lower case)
C 1973 GPU Stolle Road to Homer City line energization with surge arresters
.000050 .050 60. 60. { Decrease Tmax from .200 to .050 for speed
100 1 1 1 1
$VINTAGE, 1
1SWPA 5171.1723633
2SWPB -1.2218941
5171.4155273
3SWPC -0.0011917
-1.2218941
5171.1723633
4ST3A 15511.6093750
-3.6675410
-0.0035769
46558.4257813
5ST3B -3.6675410
15512.3398438
-3.6675410
-11.0082035
46560.6210938
6ST3C -0.0035769
-3.6675410
15511.6093750
-0.0107361
-11.0082035
46558.4296875
$VINTAGE, 0
SORA GARA 3.06
SORB GARB 3.06
SORC GARC 3.06
-1GARA ST1A .6109 2.3280 3.02 12.44
-2GARB ST1B .1278 .79260 5.36 12.44
-3GARC ST1C
1GARA ERIA 6.2245
2GARB ERIB 2.4289 6.2245
3GARC ERIC 2.4289 2.4289 6.2245
1GARA DAVA 21.905
2GARB DAVB 10.465 21.905
3GARC DAVC 10.465 10.465 21.905
-1ERIA ST1A .6701 2.3608 3.02 10.70
-2ERIB ST1B .1000 .71960 5.36 10.70
-3ERIC ST1C
-1ROLA ST1A .6342 2.3507 3.02 20.27
-2ROLB ST1B .1005 .72150 5.36 20.27
-3ROLC ST1C
-1DAVA ST1A .6641 2.3641 3.02 14.53
-2DAVB ST1B .0998 .71990 5.36 14.53
-3DAVC ST1C
-1STTA HOMA .6129 1.9245 4.50 214.0
-2STTB HOMB .0502 .59410 7.05 214.0
-3STTC HOMC
ST3A STTA .3737
ST3B STTB .3737
ST3C STTC .3737
ST1A SWIA .0415
ST1B SWIB .0415
ST1C SWIC .0415
ST3A 96514. 1930.
ST3B 96514. 1930.
ST3C 96514. 1930.
C ST3A 12.82
C ST3B 12.82
C ST3C 12.82
C SWPA 37.70
C SWPB 37.70
C SWPC 37.70
BLANK card ending all branch cards
SWIA SWPA .007940 1.0 1
SWIB SWPB .007940 1.0 1
SWIC SWPC .007940 1.0 1
BLANK card ending all switch cards
14SORA 93800. 60. 185. -1.0
14SORB 93800. 60. 65. -1.0
14SORC 93800. 60. -55. -1.0
C SWPA |TERRA *SWIA *
C SWPB |TERRA *SWIB *
C SWPC |TERRA *SWIC *
C ST3A |TERRA *TERRA *STTA *
C ST3B |TERRA *TERRA *STTB *
C ST3C |TERRA *TERRA *STTC *
C < < Etc. (many more rows) > >
BLANK card ending all source cards
ST3A ST3B ST3C HOMA HOMB HOMC SWPA SWPB SWPC
C Total network loss P-loss by summing injections = 4.805638098099E+02
C
C Last gen: SORC 53801.469729728 93800. 23.911871905618 29.188614218823
C -76836.46175431 -55.0000000 16.739103380547 34.9932955
C
C Step Time ST3A ST3B ST3C HOMA HOMB HOMC
C SWPA
C SWIB SWIC CHEN CHEN CHEN CHEN
C SWPB SWPC CURR1 FLUX1 CURR2 FLUX2
C
C CHEN CHEN CHEN CHEN
C CURR5 FLUX5 CURR6 FLUX6
C
C 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
C 0.0 0.0 0.0 0.0 0.0 0.0
C 0.0 0.0 0.0 0.0
C 100 .005 0.0 0.0 0.0 0.0 0.0 0.0
C 0.0 0.0 0.0 0.0 0.0 0.0
C 0.0 0.0 0.0 0.0
C *** Close switch "SWIA " to "SWPA " after 7.95000000E-03 sec.
C *** Close switch "SWIB " to "SWPB " after 7.95000000E-03 sec.
C *** Close switch "SWIC " to "SWPC " after 7.95000000E-03 sec.
C 200 .01 217332.128 -10970.216 -206361.84 310904.168 -111381.16 -199522.71
C -104.3596 -2103.8643 2208.14107 .734567091 -104.35883 -.18046553
C 34.0316806 -.17536706 699.245277 -.45094228
BLANK card ending selective node voltage output requests
C 1000 .05 -211428.33 122613.646 43085.5698 51552.1935 258779.757 51350.5473
C 2076.8918 -1044.8039 -3514.8485 .441798215 2076.84637 2.27394289
C 137.474393 2.17231652 -246.32711 -2.0030124
C maxima : 791162.883 546834.494 590200.117 .1071971E7 702018.441 729565.112
C 3811.90247 3682.98877 5102.5908 1.80215502 3811.88565 2.50132928
C 1378.6839 2.50169355 1701.78362 1.00436763
C Times of max : .04105 .02885 .0376 .0411 .0302 .0383
C .0269 .03635 .0392 .01325 .0269 .0168
C .01645 .01675 .02525 .03995
C minima : -551969.66 -479168.62 -639520.52 -763493.9 -536730.14 -925214.16
C -2538.3534 -5096.1259 -5475.4983 -1.8608421 -2538.2686 -.6020437
C -1273.8113 -.78766225 -1930.5746 -2.5080431
C Times of min : .01535 .03985 .0277 .0372 .01835 .0277
C .02305 .02525 .0428 .03765 .02305 .0267
C .0269 .02675 .0291 .01415
PRINTER PLOT
C For a CALCOMP (vector) plot like Fig. MVI-1 on page 20 of the Ammendment to
C the final report (Ammendment dated 23 May 1993), use this plot card:
C 144 5. 0.0 50. ST3A ST3B ST3C High voltages Voltages, V
144 2. 0.0 20. ST3A { Axis limits: (-5.520, 3.941)
BLANK card ending plot cards
BEGIN NEW DATA CASE
BLANK
EOF
C 3rd of 3 data subcases is the same as the 2nd except for 3-phase transformer
C 1973 GPU Stolle Road to Homer City line energization without surge arresters
C These extra two cases are added to document Prof. Xusheng Chen's transformer
C as described in the January and April, 1993, issues of the newsletter. The
C case came from Prof. Chen as disk file MDD6A.DAT on a floppy dated May 20,
C 1993 (this replaces the original 3rd subcase that was created 31 Mar 1993)
PRINTED NUMBER WIDTH, 11, 1, { Request default precision (cancel [13,2] of 1st)
USE SEATTLE XFORMER, DC31CHEN.DAT
C 1973 GPU Stolle Road to Homer City line energization with surge arresters
.000050 .050 60. 60. { Decrease Tmax from .200 to .050 for speed
100 1 1 1 1
$VINTAGE, 1
1SWPA 5171.1723633
2SWPB -1.2218941
5171.4155273
3SWPC -0.0011917
-1.2218941
5171.1723633
4ST3A 15511.6093750
-3.6675410
-0.0035769
46558.4257813
5ST3B -3.6675410
15512.3398438
-3.6675410
-11.0082035
46560.6210938
6ST3C -0.0035769
-3.6675410
15511.6093750
-0.0107361
-11.0082035
46558.4296875
$VINTAGE, 0
SORA GARA 3.06
SORB GARB 3.06
SORC GARC 3.06
-1GARA ST1A .6109 2.3280 3.02 12.44
-2GARB ST1B .1278 .79260 5.36 12.44
-3GARC ST1C
1GARA ERIA 6.2245
2GARB ERIB 2.4289 6.2245
3GARC ERIC 2.4289 2.4289 6.2245
1GARA DAVA 21.905
2GARB DAVB 10.465 21.905
3GARC DAVC 10.465 10.465 21.905
-1ERIA ST1A .6701 2.3608 3.02 10.70
-2ERIB ST1B .1000 .71960 5.36 10.70
-3ERIC ST1C
-1ROLA ST1A .6342 2.3507 3.02 20.27
-2ROLB ST1B .1005 .72150 5.36 20.27
-3ROLC ST1C
-1DAVA ST1A .6641 2.3641 3.02 14.53
-2DAVB ST1B .0998 .71990 5.36 14.53
-3DAVC ST1C
-1STTA HOMA .6129 1.9245 4.50 214.0
-2STTB HOMB .0502 .59410 7.05 214.0
-3STTC HOMC
ST3A STTA .3737
ST3B STTB .3737
ST3C STTC .3737
ST1A SWIA .0415
ST1B SWIB .0415
ST1C SWIC .0415
ST3A 96514. 1930.
ST3B 96514. 1930.
ST3C 96514. 1930.
C ST3A 12.82
C ST3B 12.82
C ST3C 12.82
C SWPA 37.70
C SWPB 37.70
C SWPC 37.70
BLANK card ending all branch cards
SWIA SWPA .007940 1.0 1
SWIB SWPB .007940 1.0 1
SWIC SWPC .007940 1.0 1
BLANK card ending all switch cards
14SORA 93800. 60. 185. -1.0
14SORB 93800. 60. 65. -1.0
14SORC 93800. 60. -55. -1.0
C SWPA |TERRA *SWIA *
C SWPB |TERRA *SWIB *
C SWPC |TERRA *SWIC *
C ST3A |TERRA *TERRA *STTA *
C ST3B |TERRA *TERRA *STTB *
C ST3C |TERRA *TERRA *STTC *
C < < Etc. (many more rows) > >
BLANK card ending all source cards
ST3A ST3B ST3C HOMA HOMB HOMC SWPA SWPB SWPC
C Total network loss P-loss by summing injections = 4.805638098099E+02
C
C Last gen: SORC 53801.469729728 93800. 23.911871905618 29.188614218823
C -76836.46175431 -55.0000000 16.739103380547 34.9932955
C
C Step Time ST3A ST3B ST3C HOMA HOMB HOMC
C SWPA
C SWIB SWIC CHEN CHEN CHEN CHEN
C SWPB SWPC CURR1 FLUX1 CURR2 FLUX2
C
C CHEN CHEN CHEN CHEN
C CURR5 FLUX5 CURR6 FLUX6
C
C 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
C 0.0 0.0 0.0 0.0 0.0 0.0
C 0.0 0.0 0.0 0.0
C 100 .005 0.0 0.0 0.0 0.0 0.0 0.0
C 0.0 0.0 0.0 0.0 0.0 0.0
C 0.0 0.0 0.0 0.0
C *** Close switch "SWIA " to "SWPA " after 7.95000000E-03 sec.
C *** Close switch "SWIB " to "SWPB " after 7.95000000E-03 sec.
C *** Close switch "SWIC " to "SWPC " after 7.95000000E-03 sec.
C 200 .01 217387.84 -10992.36 -206395.4 310888.096 -111376.98 -199510.83
C -104.63191 -2105.0079 2209.64051 .734405004 -104.63005 -.18043359
C 34.108862 -.17539116 699.385843 -.45096469
BLANK card ending selective node voltage output requests
C 1000 .05 -155842.05 47154.6268 -24422.789 258598.902 172156.84 -81252.716
C 2571.94767 -2427.6366 -1947.2216 .242401327 2597.62728 2.19565639
C 1.17575901 2.19555992 325.890333 -1.8799098
C maxima : 669374.836 515148.465 484746.844 .1044677E7 660808.946 731972.517
C 3607.09709 3846.82291 5375.85965 1.84806576 3607.09698 2.51948617
C 1360.93644 2.71806614 1676.35273 1.0164742
C Times of max : .0413 .01425 .03845 .04145 .03025 .0386
C .0428 .0369 .03965 .0133 .0428 .01685
C .0165 .01685 .0408 .04075
C minima : -571739.71 -410695.52 -617164.56 -648371.12 -532251.9 -900333.66
C -1991.6408 -5018.5588 -5328.1211 -1.7469988 -1991.6406 -.60320685
C -1205.0922 -.78031949 -1766.5889 -2.6833277
C Times of min : .01605 .04025 .02785 .0454 .0185 .02775
C .0232 .0408 .0433 .03805 .0232 .04275
C .0428 .04275 .02955 .03
PRINTER PLOT
C For a CALCOMP (vector) plot like Fig. MVI-1 on page 20 of the Ammendment to
C the final report (Ammendment dated 23 May 1993), use this plot card:
C 144 5. 0.0 50. ST3A ST3B ST3C High voltages Voltages, V
144 2. 0.0 20. ST3A { Axis limits: (-5.717, 3.942)
BLANK card ending plot cards
BEGIN NEW DATA CASE
BLANK
|