summaryrefslogtreecommitdiffstats
path: root/benchmarks/dc16.dat
blob: 3650a6a9e5fc67633e2f89520d46dff1ff676d67 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
BEGIN NEW DATA CASE
C     BENCHMARK DC-16
C     Test of  "SYSTEMATIC"  option which allows the user to have switch closing
C     times varied regularly.   There  are  3 independent, systematically-varied
C     switches taking 2, 4, and 3 steps,  respectively.  In addition to the base
C     case,  then,  there  are to be   2 * 4 * 3 = -NENERG = 24   energizations.
PRINTED NUMBER WIDTH, 13, 2,  { Request maximum precision (for 8 output columns)
99.03E-6    .025     60.
       1       1       1       2       1      -1                     -24
C    ISW   ITEST   IDIST    IMAX   IDICE  KSTOUT                           NSEED
       1       1      { ISW=1 ==> Printed switching times;   ITEST=1 ==> no bias
       5       5      20      20      { Printout frequency changes for base case
 0GENA  A1                      7.                                             4
 0GENB  B1                      7.                                             3
 0GENC  C1                      7.
 0ENDA  A10                     7.
 0ENDB  B10                     7.
 0ENDC  C10                     7.
-1ASW1  A5                .3    2.1146 0.645 50.   0
-2BSW1  B5                .0268 .5397  0.021 50.   0
-3CSW1  C5
 0A5    A5F               1.
 0B5    B5F               1.
 0C5    C5F               1.
-1A5F   ASW10 ASW1  A5
-2B5F   BSW10
-3C5F   CSW10
BLANK card ending branch cards
  B10   BSW10     10.E-3     1.0
  B1    BSW1       4.E-3     .2E-3         2          SYSTEMATIC
  C1    CSW1       6.E-3     .3E-3         4          SYSTEMATICTARGET
  A10   ASW10      2.E-3     .4E-3         3          SYSTEMATIC
  A1    ASW1       1.E-3                              SYSTEMATICB1    BSW1
  C10   CSW10     12.E-3     1.0
BLANK card ending switch cards
14GENA     303.       60.         0.0                        -1.
14GENB     303.       60.      -120.0                        -1.
14GENC     303.       60.       120.0                        -1.
14ENDA     303.       60.      - 10.0                        -1.
14ENDB     303.       60.      -130.0                        -1.
14ENDC     303.       60.       110.0                        -1.
BLANK card ending source cards
  ASW1  BSW1
BLANK card ending output variable requests (node voltages only, here)
C ***          Close switch  "B1    "  to  "BSW1  "  after  6.04083000E-03  sec.
C ***          Close switch  "C1    "  to  "CSW1  "  after  6.04083000E-03  sec.
C ***          Close switch  "A10   "  to  "ASW10 "  after  6.04083000E-03  sec.
C ***          Close switch  "A1    "  to  "ASW1  "  after  7.03113000E-03  sec.
C  80 .0079224   3.639449214   12.5053685  -283.627168  177.6693051  .5124656E-3
C 100  .009903   1.299612647  -58.9506992  -271.930029  38.31674092  .6510477E-4
C ***          Close switch  "B10   "  to  "BSW10 "  after  1.00020300E-02  sec.
C 120 .0118836   -13.4793168  7.386747874  -54.0094052   -227.85024  .0068001249
C ***          Close switch  "C10   "  to  "CSW10 "  after  1.20816600E-02  sec.
C
C Last step:  252 .02495556   -2.83666996  -5.98940516  -327.625802  161.8641485
C Last step continued  .......                          .1629402E-3  .3686585491
  PRINTER PLOT
 144 4. 0.0 50.         ASW1                     { Axis limits: (-3.276,  3.176)
C                       GENA         GENB         ASW1         BSW1         GENA
C                         A1           B1                                     A1
C First shot:               Random switching times for energization number  1  :
C   2  5.9000000E-03    3  6.0000000E-03    4  5.6000000E-03    5  6.9000000E-03
C                58.93128751  192.0984488  -326.075521  336.1486991  .0315970504
C Times of maxima : .0138642    .00604083    .02495556    .00722919    .01554771
C
C 2nd   shot:               Random switching times for energization number  2  :
C   2  6.1000000E-03    3  6.0000000E-03    4  5.6000000E-03    5  7.1000000E-03
C                56.04192203  165.7654174  -322.282369  -326.291206  .0329276386
C Times of maxima : .01267584   .00623889    .02495556    .01346808    .01574577
BLANK card ending plot cards (for base case only)
C 23rd shot:               Random switching times for energization number  23  :
C 23rd shot:  2  6.8000000E-3  3  6.9000000E-3  4  7.3000000E-3  5  7.8000000E-3
C 23rd shot:     -39.0656922  169.6381869  -379.444302  -311.343589  .0253668269
C Times of maxima: .01742928     .0069321    .00812046    .01346808    .01673607
C
C Last shot:               Random switching times for energization number  24  :
C Last shot:  2  7.0000000E-3  3  6.9000000E-3  4  7.3000000E-3  5  8.0000000E-3
C Last shot:     49.82358949  165.4706377  -382.803147  310.7780459  .0299093498
C Last shot:       .01356711    .00713016    .00812046    .02188563    .01673607
C
C 1 ) --------------------------------------------------------------------------
C Statistical distribution of peak voltage  for branch  "GENB  "  to   "B1    ".
C Interval             voltage         voltage  in      Frequency     Cumulative
C   number         in per unit      physical units      (density)      frequency
C       57           2.8500000      0.14250000E+03              0              0
C       58           2.9000000      0.14500000E+03              1              1
C          <  <  Etc.  (rows 59 through 75 omitted to save space)   >  >
C       76           3.8000000      0.19000000E+03              0             21
C       77           3.8500000      0.19250000E+03              3             24
C Summary for following request:        Mean = 3.48750000E+00     3.49384237E+00
C                                   Variance = 5.61413043E-02     5.91771084E-02
C                         Standard deviation = 2.36941563E-01     2.43263455E-01
-1  50.       GENB  B1
C 2 ) --------------------------------------------------------------------------
C Statistical distribution of peak voltage at node  "ASW1  ".   The base voltage
C Interval             voltage         voltage  in      Frequency     Cumulative
C   number         in per unit      physical units      (density)      frequency
C       21           1.0500000      0.31815000E+03              0              0
C       22           1.1000000      0.33330000E+03              5              5
C       23           1.1500000      0.34845000E+03              5             10
C       24           1.2000000      0.36360000E+03              3             13
C       25           1.2500000      0.37875000E+03              5             18
C       26           1.3000000      0.39390000E+03              3             21
C       27           1.3500000      0.40905000E+03              3             24
C Distribution parameters for .. data follow.    Grouped data     Ungrouped data
C                                       Mean = 1.18541667E+00     1.18028303E+00
C                                   Variance = 7.38677536E-03     6.74976204E-03
C                         Standard deviation = 8.59463517E-02     8.21569354E-02
 0            ASW1  BSW1   { See preceding comments for 1st of 3 tables produced
C                         MODTAB   AINCR  XMAXMX
STATISTICS DATA                0    -15.     0.0   ----  Fixed 15 boxes used now
C 5 ) --------------------------------------------------------------------------
C Statistical distribution of peak current  for branch  "GENB  "  to   "B1    ".
C Interval             current         current  in      Frequency     Cumulative
C   number         in per unit      physical units      (density)      frequency
C       19           0.9976152      0.95970790E+00              0              0
C       20           1.0501213      0.10102188E+01              2              2
C       21           1.1026274      0.10607298E+01              0              2
C          <  <  Etc.  (rows 22 through 32 omitted to save space)   >  >
C       33           1.7327002      0.16668611E+01              0             22
C       34           1.7852062      0.17173720E+01              2             24
C Distribution parameters for .. data follow.    Grouped data     Ungrouped data
C                                       Mean = 1.40672501E+00     1.39937500E+00
C                                   Variance = 3.96702046E-02     3.93384525E-02
C                         Standard deviation = 1.99173805E-01     1.98339236E-01
-2            GENB  B1  { See preceding comment cards for resulting single table
-3            GENA  A1 { Ungrouped: Mean= 1.63806617E0, Variance = 1.01307955E-1
-4            GENA  A1 { Ungrouped: Mean= 1.30997561E0, Variance = 1.73383337E-2
C                         MODTAB   AINCR  XMAXMX     15 Aug 03, add Sturges use:
STATISTICS DATA                0 Sturges     0.0  ----  Sturges gives # of boxes
-4            GENA  A1 { Ungrouped: 
C 8 ) -------------------------------------------------------------------------------------------------------------------------------
C Statistical distribution of peak energy   for branch  "GENA  "  to  "A1    ".   Base energy   for per unit output = 2.33417187E-02
C  Interval           energy          energy   in     Frequency    Cumulative               Per cent
C    number       in per unit      physical units     (density)     frequency     .GE. current value
C         9          .9050250      2.11248398E-02             0             0          100.000000
C        10         1.0055834      2.34720442E-02             1             1           95.833333
C        11         1.1061417      2.58192486E-02             2             3           87.500000
C        12         1.2067000      2.81664531E-02             2             5           79.166667
C        13         1.3072584      3.05136575E-02             5            10           58.333333
C        14         1.4078167      3.28608619E-02             9            19           20.833333
C        15         1.5083751      3.52080663E-02             5            24             .000000
C Summary of preceding table follows:       Grouped data     Ungrouped data
C                                 Mean = 1.29887852E+00     1.30997561E+00
C                             Variance = 1.92713806E-02     1.73383337E-02
C                   Standard deviation = 1.38821398E-01     1.31675107E-01
BLANK card ending  "SYSTEMATIC"  output-variable requests
BEGIN NEW DATA CASE
C   2nd of 3 subcases is related to 1st in that it demonstrates SYSTEMATIC use.
C   But network is single phase and much simpler.  Basically, a 50-Hz generator
C   will charge a capacitor upon switch closure.  Illustrate different options:
C     a) Misc. data KSSOUT of column 32 is 3 whereas in DC-16 it was 2.  The
C        difference is a phasor branch flow (now seen) for the base case.
C     b) Misc. data MAXOUT of column 40 is zero whereas in DC-16 it was 1.  But
C        this makes no difference.  The base case show extrema either way.
C     c) Misc. data  MEMSAV of column 56 is 2 meaning that program tables will  
C        be partially dumped, as 3rd subcase of DC-24 (STATISTICS).  For ease of
C        documentation, this will be  FORMATTED  rather than  UNFORMATTED  (note
C        FORM=  of the  $OPEN  statement).
C     d) IMAX, read from cols. 25-32 of the  STATISTICS/SYSTEMATIC  misc. data
C        card,  has value 1 to request the addition of normal, non-statistic
C        extrema.
C     e) There is a single  SYSTEMATIC  switch.  NENERG of the misc. data card
C        can be found without the minus sign in column 44 of the switch card.
C     f) Illustrate  PARTIAL TABLE DUMPING  for faster table dumping.  This
C        illustration is added  5 October 2001.
PARTIAL TABLE DUMPING { Faster table dumping (dump only what is used, not limit)
PRINTED NUMBER WIDTH, 10, 2,  { Request maximum precision (for 8 output columns)
 .000500    .010  { Take 20 steps over half a cycle of the 50-Hz power frequency
C   IOUT   IPLOT  IDOUBL  KSSOUT  MAXOUT                          NENERG
       1       1       1       3       0      -1                      -4
C    ISW   ITEST   IDIST    IMAX   IDICE  KSTOUT                           NSEED
       1       1       0       1       1                                       1
       5       1    { Printout frequency remains unchanged; print each time step
  GEN   SWIT                 1.0                                               1
  SWIT                       1.0                                             
  CAP                        0.0   0.0 1.0E3                                   3
BLANK card ending branch cards
  SWIT  CAP        5.E-3     1.E-3         4          SYSTEMATIC
BLANK card ending switch cards
14GEN      400.       50.         0.0                        -1.
BLANK card ending source cards
$OPEN,  UNIT=LUNIT9  FILE=systemat.lu9  STATUS=UNKNOWN  FORM=FORMATTED !
  GEN   SWIT  CAP 
BLANK card ending output variable requests (node voltages only, here)
  PRINTER PLOT
 184 2. 4.0 10.         CAP         GEN   SWIT
BLANK card ending plot cards (for base case only)
$CLOSE,  UNIT=LUNIT9  STATUS=KEEP      { Disconnect to prevent damage by stray  WRITE 
$OPEN,  UNIT=LUNIT9  FILE=dum.lu9  STATUS=UNKNOWN  FORM=FORMATTED !
-2    500.    CAP  { Tabulate branch current of (CAP, TERRA) using I-base = 500.
BLANK card ending statistical tabulate (none possible, since no output variable)
BEGIN NEW DATA CASE
C   3rd of 3 subcases is same as 2nd except for the following changes:
C     a) Add  OMIT BASE CASE  to drop the base case (no normal dT-loop output
C        preceding the 4 energizations indicated by NENERG.
C     b) IMAX, read from cols. 25-32 of the  STATISTICS/SYSTEMATIC  misc. data
C        card,  has value 2 to request the replacement of statistical extrema
C        by normal, non-statistic extrema.
C     c) Misc. data MAXOUT of column 40 is 1.  But this makes no difference.
C     d) Misc. data KSSOUT of column 32 is 2 as in DC-16.  This omits the
C        phasor branch flow of the preceding subcase.
OMIT BASE CASE   { Energizations will not be preceded by normal dT-loop output
 .000500    .010
C   IOUT   IPLOT  IDOUBL  KSSOUT  MAXOUT                          NENERG
       1       1       1       3       1      -1                      -4
C    ISW   ITEST   IDIST    IMAX   IDICE  KSTOUT                           NSEED
       1       1       0       2       1                                       1
       5       5           { Less dT-loop output after time step number 5
  GEN   SWIT                 1.0                                               1
  SWIT                       1.0                                             
  CAP                        0.0   0.0 1.0E3                                   3
BLANK card ending branch cards
  SWIT  CAP        5.E-3     1.E-3         4          SYSTEMATIC
BLANK card ending switch cards
14GEN      400.       50.         0.0                        -1.
BLANK card ending source cards
C $OPEN,  UNIT=LUNIT9  FILE=systemat.lu9  STATUS=UNKNOWN  FORM=FORMATTED !
  GEN   SWIT  CAP 
BLANK card ending output variable requests (node voltages only, here)
$DISABLE         { Comment out this card, if a base case solution is to be added
  PRINTER PLOT
BLANK card ending plot cards (for base case only)
$ENABLE          { Comment out this card, if a base case solution is to be added
C $CLOSE,  UNIT=LUNIT9  STATUS=KEEP      { Disconnect to prevent damage by stray  WRITE 
-2    500.    CAP  { Tabulate branch current of (CAP, TERRA) using I-base = 500.
BLANK card ending statistical tabulate (none possible, since no output variable)
BEGIN NEW DATA CASE
BLANK  
EOF