summaryrefslogtreecommitdiffstats
path: root/benchmarks/dcn31.dat
diff options
context:
space:
mode:
authorAngelo Rossi <angelo.rossi.homelab@gmail.com>2023-06-21 12:04:16 +0000
committerAngelo Rossi <angelo.rossi.homelab@gmail.com>2023-06-21 12:04:16 +0000
commitb18347ffc9db9641e215995edea1c04c363b2bdf (patch)
treef3908dc911399f1a21e17d950355ee56dc0919ee /benchmarks/dcn31.dat
Initial commit.
Diffstat (limited to 'benchmarks/dcn31.dat')
-rw-r--r--benchmarks/dcn31.dat55
1 files changed, 55 insertions, 0 deletions
diff --git a/benchmarks/dcn31.dat b/benchmarks/dcn31.dat
new file mode 100644
index 0000000..c627272
--- /dev/null
+++ b/benchmarks/dcn31.dat
@@ -0,0 +1,55 @@
+BEGIN NEW DATA CASE
+C BENCHMARK DCNEW-28
+C 1st of ?? subcases illustrates creation of new C-like .PL4 file that was
+C inspired by Massimo Ceraolo of the University of Pisa in Italy. The date
+C of addition is 11 March 1999, and mention should be found in later issues
+C of the newsletter. There are no dynamics. The network is resistive, and
+C all voltages and currents are sinusoidal. An attempt has been made to
+C involve different types of variables: 1 branch voltage first, then a power,
+C then two node voltages, then a branch current, then energy, and finally,
+C a TACS signal (also power). The new C-like format should be better than
+C the old for concurrent, SPY-like plotting.
+$BEGIN PL4 COMMENTS
+C Massimo Ceraolo of the University
+C of Pisa in Italy can plot SPY-like.
+$END PL4 COMMENTS
+PRINTED NUMBER WIDTH, 9, 2,
+$DEPOSIT, NEWPL4=2 { Special value that characterizes new C-like .PL4 file type
+ .0005 .020
+ 1 1 1 0 0 0 0 2
+TACS HYBRID
+90GEN { Electric network source voltage
+91SWIT { Electric network switch current
+99VOLT = 0.5 * GEN { Half the source voltage = branch voltage
+99POWER = VOLT * SWIT { Branch power consumption = v(t) * i(t)
+33POWER { Output branch power
+BLANK card ending all TACS data
+ SWIT SEND 1.0 2
+ SEND 1.0 4
+BLANK card ending branch cards
+ GEN SWIT MEASURING 1
+BLANK card ending switch cards
+14GEN 100. 50.
+BLANK card ending source cards
+ SWIT SEND
+C First 4 output variables are electric-network voltage differences (upper voltage minus lower voltage);
+C Next 2 output variables are branch currents (flowing from the upper node to the lower node);
+C Next 1 output variables belong to TACS (with "TACS" an internally-added upper name of pair).
+C Branch power consumption (power flow, if a switch) is treated like a branch voltage for this grouping (1 variables);
+C Branch energy consumption (energy flow, if a switch) is treated like a branch current for this grouping (1 variables).
+C Step Time SWIT SEND SWIT SEND GEN SEND TACS
+C SEND TERRA SWIT TERRA POWER
+C *** Switch "GEN " to "SWIT " closed before 0.00000000E+00 sec.
+C 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
+C 1 .5E-3 49.3844 2438.82 98.7688 49.3844 49.3844 .609705 2438.82
+C 2 .1E-2 47.5528 2261.27 95.1057 47.5528 47.5528 1.78473 2261.27
+C 3 .0015 44.5503 1984.73 89.1007 44.5503 44.5503 2.84623 1984.73
+C .PL4 type code: 8 6 4 4 9 7 2
+C Variable class: V-bran Power V-node V-node I-bran Energy TACS
+BLANK card ending requests for node voltage output
+ PRINTER PLOT
+ 194 2. 0.0 20. SEND GEN SWIT
+BLANK card ending plot cards
+BEGIN NEW DATA CASE
+BLANK
+