diff options
author | Angelo Rossi <angelo.rossi.homelab@gmail.com> | 2023-06-21 12:04:16 +0000 |
---|---|---|
committer | Angelo Rossi <angelo.rossi.homelab@gmail.com> | 2023-06-21 12:04:16 +0000 |
commit | b18347ffc9db9641e215995edea1c04c363b2bdf (patch) | |
tree | f3908dc911399f1a21e17d950355ee56dc0919ee /benchmarks/dcn10.dat |
Initial commit.
Diffstat (limited to 'benchmarks/dcn10.dat')
-rw-r--r-- | benchmarks/dcn10.dat | 212 |
1 files changed, 212 insertions, 0 deletions
diff --git a/benchmarks/dcn10.dat b/benchmarks/dcn10.dat new file mode 100644 index 0000000..275ba4f --- /dev/null +++ b/benchmarks/dcn10.dat @@ -0,0 +1,212 @@ +BEGIN NEW DATA CASE
+C BENCHMARK DCNEW-10
+C Test of U.M. for the option of data that is nearly compatible with the
+C Type-59 S.M. Like DCNEW-9, only here compensation will NOT be employed
+C Also, the general interface to send any U.M. variables to TACS will be
+C illustrated, even though TACS does nothing with those variables.
+UM TO TACS { Declaration for special connection of Type-92 TACS sources to U.M.
+PRINTED NUMBER WIDTH, 13, 2, { Request maximum precision (if 8 output columns)
+NAMES ARE LEFT ADJUSTED { ATP will halt if any A6 name begins with a blank
+C NAMES ARE RIGHT ADJUSTED { ATP will halt if any A6 name ends with a blank
+C Left-adjusted names are the most common, but right-adjusted names also are
+C possible as the preceding comment demonstrates. Protection against failure
+C to do either begins 11 January 2001. Once turned on, either service remains
+C in effect unless and/or until the other is declared, or execution ends. That
+C is why declaration here in the first subcase is sufficient for illustration
+C of KILL = 81 in the 2nd subcase.
+ .000200 .150 60. 60.
+ 1 1 1 1 1 -1
+ 5 5 20 20 100 100 500 500
+TACS HYBRID { We use TACS only to illustrate the definition by U.M. variables
+92TQGEN { Name of Type-92 TACS source must be the same as 1st of 2 U.M. variabl
+C Note that the preceding connection was especially simple because there
+C is no need to be concerned about the number of the U.M. (here, only 1).
+C More generally, the otherwise unused columns 41-52 have been reserved
+C for the machine variable as 2A6 information. E.g., "UM-1 OMEGM ".
+C In this case, note that the name of columns 3-8 is arbitrary. But for
+C the simple case (here) where columns 41-52 are blank, the 1st machine
+C that has an output variable matching the name of columns 3-8 will be
+C accepted for the connection. The 2nd of 2 connections will follow. On
+C a comment card, first, will the the simplied form. It will be followed
+C by the real connection in general form. Note that within TACS, the
+C U.M. variable IE1 has been given the name FIELD:
+C 92IE1 { 2nd of 2 Type-92 TACS sources would be this way if simplified form
+92FIELD UM-1 IE1 { Connect IE1 of UM-1 to FIELD
+33TQGEN FIELD { Output the just-defined variables (should equal U.M. outputs)
+BLANK card ending all TACS data
+$BLANK HALT { Halt execution if any truly blank card is found (see 2nd subcase)
+51NAVH AMCC1 A 162.67 507.51
+52NAVH BMCC1 B 6.51 162.97
+53NAVH CMCC1 C
+ MCC1 AMCC2 A 8285.
+ MCC1 BMCC2 B 8285.
+ MCC1 CMCC2 C 8285.
+ MCC2 AEQV A 19.52
+ MCC2 BEQV B 19.52
+ MCC2 CEQV C 19.52
+ TRANSFORMER TRAN A
+ 9999
+ 1NAVL ANAVL C .1 26.
+ 2NAVH A 31.23 311.09
+ TRANSFORMER TRAN A TRAN B
+ 1NAVL BNAVL A
+ 2NAVH B
+ TRANSFORMER TRAN A TRAN C
+ 1NAVL CNAVL B
+ 2NAVH C
+ NAVL A 2500. 1.13
+ NAVL B 2500. 1.13
+ NAVL C 2500. 1.13
+ SWT AMCC2 A 4830.
+ SWT BMCC2 B 4830.
+ SWT CMCC2 C 4830.
+ MCC2 ASWT A 13.01
+ MCC2 BSWT B 13.01
+ MCC2 CSWT C 13.01
+BLANK card ending branch cards
+ SWT A .01661667 .09161667
+ SWT B .01661667 .09161667
+ SWT C .01661667 .09161667
+BLANK card ending switch cards
+14EQV A 389997. 60. -93.81293 -1.
+14EQV B 389997. 60. -213.81293 -1.
+14EQV C 389997. 60. 26.18707 -1.
+19 UM
+ SMDATA 1 { The "1" in column 15 requests prediction (not compensation)
+BLANK card ending Class-1 U.M. data cards
+59NAVL A 21229. 60. -44.896562
+ NAVL B
+ NAVL C
+C TOLERANCES 10. .0001 .00001
+PARAMETER FITTING 1.
+ 6 5 2 1. 1. 892.4 26. +1800. 1907. 3050.
+C -1.
+ .13 1.79 1.71 .169 .228 .13504 .20029
+ 4.3 .85 .032 .05 .13
+ 1 .3 .027691 33.68813 BUSM1
+ 2 .26 .046379 60.9591
+ 3 .22 .255958 90.81823 BUSM3
+ 4 .22 .263573 123.6634 BUSM4
+ 5 .258887 4.925036 BUSM5
+ 6 .0101995 BUSM6
+C Note about the preceding 6 mass cards of Type-59 S.M. data. The name of
+C columns 71-76 of any one is for the associated mechanical node that EMTP
+C will create (needed for capacitor to ground). Beginning 24 August 1993,
+C this can be left blank if the user is willing to accept a default name of
+C the form "MASSXX" where the last 2 bytes will be serialized 01, 02, ...
+C By erasing the name BUSM2 on the second card, name MASS02 will replace
+C this for output identification of the speed or angle of mass 2.
+ 11111111 333333
+ FINISH
+BLANK card ending all U.M. data cards
+BLANK card ending all source cards (including the U.M.)
+C Total network loss P-loss by summing injections = 1.775796786600E+07
+C Total network loss P-loss by summing injections = 7.638165971780E+16
+C Total network loss P-loss by summing injections = 7.637910321429E+16
+C Total network loss P-loss by summing injections = 7.638932291442E+16
+C Output for steady-state phasor switch currents.
+C Node-K Node-M I-real I-imag I-magn
+C SWT A Open Open Open
+C SWT B Open Open Open
+C SWT C Open Open Open
+C BUSM2 BUSM1 -6.37300003E+05 2.75937500E+01 6.37300004E+05
+C BUSM3 BUSM2 -1.18962667E+06 7.40000000E+01 1.18962667E+06
+C BUSM4 BUSM3 -1.65698001E+06 3.29125000E+02 1.65698004E+06
+C BUSM5 BUSM4 -2.12433334E+06 5.92375000E+02 2.12433343E+06
+C BUSM6 BUSM5 0.00000000E+00 -1.01718750E+01 1.01718750E+01
+C
+C EQV C 349966.92087687 389997. -1273.107108884 1348.5187481005
+C 172106.98504408 26.1870700 -444.6359221728 -160.7481140
+ NAVH ANAVH BNAVH C
+C Step Time BUSM1 MASS02 BUSM3 BUSM4 BUSM5 BUSM6 NAVH A NAVH B
+C TERRA TERRA TERRA TERRA TERRA TERRA
+C
+C NAVH C MASS02 BUSM3 BUSM4 BUSM5 BUSM6 TACS TACS
+C BUSM1 MASS02 BUSM3 BUSM4 BUSM5 TQGEN FIELD
+C
+C UM-1 UM-1 UM-1 UM-1 UM-1 UM-1 UM-1 UM-1
+C TQGEN IPA IPB IPC IE1 IE2 IE3 IE4
+C *** Phasor I(0) = -6.3730000E+05 Switch "BUSM2 " to "BUSM1 " closed
+C *** Phasor I(0) = -1.1896267E+06 Switch "BUSM3 " to "BUSM2 " closed
+C *** Phasor I(0) = -1.6569800E+06 Switch "BUSM4 " to "BUSM3 " closed
+C *** Phasor I(0) = -2.1243333E+06 Switch "BUSM5 " to "BUSM4 " closed
+C *** Phasor I(0) = 0.0000000E+00 Switch "BUSM6 " to "BUSM5 " closed
+C 0 0.0 376.9911184 376.9911184 376.9911184 376.9911184 376.9911184 376.9911184 54291.46171 -385072.283
+C 330780.8214 -637300.003 -.1189627E7 -.165698E7 -.2124333E7 0.0 0.0 0.0
+C .21243333E7 9214.54515 -27456.1142 18241.56904 4313.224983 0.0 0.0 0.0
+C 1 .2E-3 376.9911184 376.9911184 376.9911184 376.9911184 376.9911187 376.9911184 85269.74103 -396001.181
+C 310731.44 -637300.003 -.1189627E7 -.165698E7 -.2124333E7 -.192711E-3 .21243018E7 4313.233628
+C .21243018E7 11174.95518 -27770.8483 16595.89276 4313.233628 .6697334554 .6667285885 .2799719954
+C 2 .4E-3 376.9911184 376.9911184 376.9911184 376.9911184 376.9911198 376.9911184 115771.1286 -404685.302
+C 288914.173 -637300.003 -.1189627E7 -.165698E7 -.2124333E7 -.001299907 .21242469E7 4313.23836
+C .21242469E7 13071.84176 -27927.6144 14855.77263 4313.23836 1.005987367 1.411747548 .5923226394
+BLANK card ending output requests (here, just node voltages)
+C *** Open switch "SWT C" to " " after 1.00200000E-01 sec.
+C 750 .15 378.9579362 378.7971923 378.5677025 378.0740682 377.9402794 362.6550115 65967.40283 -252359.489
+C 236314.7086 -.1741593E7 -.3694241E7 -.8111971E7 -.3604052E7 -368811.077 -460638.075 5379.270269
+C -460638.075 -21046.2714 -15182.1684 36228.43977 5379.270269 -9232.64421 26381.86541 10855.49107
+C maxima : 387.546885 384.6217924 381.1685641 380.8913616 381.7465385 390.8419992 669322.4023 586897.097
+C 532948.8001 656967.1906 .13443971E7 .27857511E7 .10534159E7 763826.7801 .71276709E7 6509.720036
+C .71276709E7 75438.29546 60328.31828 75306.29416 6509.720036 45317.49759 40466.3349 15877.68389
+C Times of max : .1358 .1368 .1382 .116 .1124 .12 .1202 .1264
+C .1148 .1226 .1234 .1258 .0582 .1342 .1276 .0908
+C .1276 .1368 .0444 .1298 .0908 .1382 .0434 .0434
+C minima : 370.1878672 373.9938537 376.0186341 375.3497638 375.1213723 361.1452453 -592541.345 -633283.817
+C -571219.198 -.1828159E7 -.3694241E7 -.8111971E7 -.4003952E7 -499216.781 -.1775882E7 0.0
+C -.1775882E7 -76280.1719 -68226.6079 -73182.9387 3602.587589 -55011.5332 -43534.6089 -18695.7515
+C Times of min : .111 .1106 .0518 .1402 .138 .1464 .1116 .1178
+C .1234 0.1 .15 .15 .1406 .1078 .1024 0.0
+C .1024 .127 .0356 .0414 .1156 .1132 .126 .1258
+ PRINTER PLOT
+ 19415. 150. UM-1 TQGEN { Axis limits : (-1.776, 7.128)
+ 18415. 150. BUSM6 { Axis limits : (0.000, 3.908)
+BLANK card ending all plot cards
+BEGIN NEW DATA CASE
+C 2nd subcase illustrates halt due to NAMES ARE LEFT ADJUSTED (NALA) as
+C left over from the 1st subcase. Data is from 3rd subcase of DC-20 as
+C added 11 January 2001. All TACS variables except 1 have been deleted,
+C and this one (OUT1) has been shifted right by one byte to create an
+C error. Also, on the electrical side, NOD2 has been shifted right
+C by one byte. So, there are two errors. Either one would be enough
+C to halt execution.
+ .0001 0.02
+ 1 1 1 1 1 -1
+ 10 10 100 100
+TACS HYBRID
+ 1 OUT1 +GEN1
+ 1.0
+ 1.0 1.0
+14GEN1 100000. 400.0 -1.0
+33 OUT1
+BLANK card ends final TACS data
+ NOD1 NOD2 1.00
+BLANK card after last electric network branch
+ NOD2 -1.0 1.0
+BLANK card ends switches
+14NOD1 -1 100.0 50.0 -1.0
+BLANK card after last electric network source
+C Auxiliary name " OUT1 " is not properly left-adjusted or right-adjusted. This is for TEXVEC cell 15 out of a total of 18.
+C Bus name " NOD2 " is not properly left-adjusted or right-adjusted. This is for node number 3 out of a total of 3.
+C ------------------------------------------------------------------------------------------------------------------------------------
+C ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/
+C ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ ... Etc. (boiler plate until we come to following)
+C KILL code number Overlay number Nearby statement number
+C 81 4 8299
+C KILL = 81. A 6-character data name is not properly left-adjusted or right-adjusted as the preceding warning message documents. Of
+ NOD1 NOD2
+BLANK card ends selective node voltage outputs
+BLANK card terminating plotting
+BEGIN NEW DATA CASE
+C Non-existent 3rd data subcase is used only to illustrate termination
+C on a truly blank card. This will happen because $BLANK HALT appears
+C earlier (in fact, in a preceding data subcase). As explained in the
+C October, 1993, newsletter, STARTUP variable NOBRAN could be used
+C instead of this $-card, which is restricted to just this disk file.
+
+BLANK { 14 Dec 94, we add more, to make 5 even when comments are destroyed
+BLANK { 14 Dec 94, we add more, to make 5 even when comments are destroyed
+BLANK { 14 Dec 94, we add more, to make 5 even when comments are destroyed
+BLANK { 14 Dec 94, we add more, to make 5 even when comments are destroyed
+BLANK { 14 Dec 94, we add more, to make 5 even when comments are destroyed
+BEGIN NEW DATA CASE
+BLANK
|