diff options
author | Angelo Rossi <angelo.rossi.homelab@gmail.com> | 2023-06-21 12:04:16 +0000 |
---|---|---|
committer | Angelo Rossi <angelo.rossi.homelab@gmail.com> | 2023-06-21 12:04:16 +0000 |
commit | b18347ffc9db9641e215995edea1c04c363b2bdf (patch) | |
tree | f3908dc911399f1a21e17d950355ee56dc0919ee /benchmarks/dc21.dat |
Initial commit.
Diffstat (limited to 'benchmarks/dc21.dat')
-rw-r--r-- | benchmarks/dc21.dat | 545 |
1 files changed, 545 insertions, 0 deletions
diff --git a/benchmarks/dc21.dat b/benchmarks/dc21.dat new file mode 100644 index 0000000..4e8e80c --- /dev/null +++ b/benchmarks/dc21.dat @@ -0,0 +1,545 @@ +BEGIN NEW DATA CASE
+C BENCHMARK DC-21
+C Test of various TACS devices, types 50-56. There is no electric network,
+C and no physical or other coherent meaning. Components are disconnected.
+C 1st of 9 subcases begins. Change 12 Jan 98: In STARTUP, TIMTAC is reduced
+C from 1.0 to 0.99 in order to ensure the warning
+C message of Type-50 device "DEV50I". It is on step 10
+C that the zero crossing is noted, and 10 * 0.1 may be less
+C than TIMTAC = 1.0 (sometimes roundoff produced a message, at
+C other times it did not). Reduce TIMTAC to eliminate the uncertainty.
+$PREFIX, [] { $INCLUDE files are located in same place as this main data file
+C Preceding line allows the SEEK file to be remote if this main data file is
+ 0.1 1.2
+ 1 1 0 0 1
+TACS STAND ALONE
+C 8 May 2011, add illustration of new "SEEK" option of Type-56 device. This
+C uses the logic of Orlando Hevia's new MODELS "SEEK" function (which is just
+C improved MODELS POINTLIST) instead of the usual TACS logic for nonlinear
+C (X, Y) interpolation. Begin with the new optional TACS miscell. data card:
+C 3456789012345678901234567890123456789012345678 -- Ruler for following optional
+C < File Name> IPRMDL KOMPAC miscellaneous data card :
+TACS MISC. DATA dc21seek. 0 0
+ QUART +MIDDLE 0.5
+ MIDDLE +UNITY 0.6
+14SOURCE 1.0.833333333
+88DEV50I50+SOURCE 0.8 3.0 { Apr 97, add 3%
+88DEV50N50+SOURCE
+88DEV51O51+UNITY 0.6 SOURCE
+88DEV51C51+UNITY 1.MIDDLESOURCE
+88DEV52C52+UNITY 0.6 1. SOURCE
+88DEV52O52+UNITY MIDDLESOURCE
+88DEV53F53+SOURCE 0.3
+88DEV53V53+SOURCE 0.6MIDDLE
+88DEV54F54+DEV52C 0.3
+88DEV54V54+DEV52O -0.2 0.3 QUART
+88DEV55 55+SOURCE
+ -1.0
+ -0.5
+ 0.0
+ 0.5
+ 1.0
+ 9999.
+88DEV56 56+SOURCE
+ -1.0 0.0
+ -0.5 0.5
+ 0.0 0.0
+ 0.5 0.5
+ 1.0 0.0
+ 9999.
+C 8 May 2011 WSM adds a second Type-56 device that is identical to the one just
+C inputted. But this second is different in that it has no inline (X,Y) points.
+C Instead, it uses Orlando Hevia's new "SEEK" function of MODELS to produce the
+C identically-same answer. The characteristic of (X, Y) points has been moved
+C to the separate disk file DC21SE45.DAT where root name DC21SEEK is defined
+C by the optional TACS misc. data card. Integer 45 is the function number that
+C is defined by device parameter "B" of columns 57-62. Finally, columns 69-80
+C are to be keyed with the special request word "MODELS SEEK " as shown :
+C Type-56 device allows MODELS "SEEK" : SEEK function # Key word--->
+88SEE56 56+SOURCE 45 MODELS SEEK
+33QUART MIDDLETIMEX UNITY SOURCEDEV50IDEV50NDEV51ODEV51C
+33DEV52CDEV52ODEV53FDEV53VDEV54FDEV54VDEV55 DEV56 SEE56
+77DEV52O 1.0
+77QUART 0.3
+77MIDDLE 0.6
+C Column headings for the 18 EMTP output variables follow. These are divided among the 5 possible classes as follows ....
+C Next 18 output variables belong to TACS (with "TACS" an internally-added upper name of pair).
+C Step Time TACS TACS TACS TACS TACS TACS TACS TACS TACS TACS
+C QUART MIDDLE TIMEX UNITY SOURCE DEV50I DEV50N DEV51O DEV51C DEV52C
+C
+C TACS TACS TACS TACS TACS TACS TACS TACS
+C DEV52O DEV53F DEV53V DEV54F DEV54V DEV55 DEV56 SEE56
+C 0 0.0 0.3 0.6 0.0 1.0 0.0 0.8 0.0 0.0 0.0 0.0
+C 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
+C MODELS "SEEK" function # 45 involves 5 pairs of (X,Y). These are stored in List-20 SCONST cells 3 through 12.
+C 1 0.1 0.3 0.6 0.1 1.0 .866025404 0.8 0.0 1.0 0.0 0.0
+C 1.0 0.0 0.0 0.0 0.0 0.5 .133974596 .133974596
+C 2 0.2 0.3 0.6 0.2 1.0 0.5 0.8 0.0 0.0 1.0 1.0
+C 0.0 0.0 0.0 0.0 0.0 0.5 0.5 0.5
+BLANK card that ends TACS data cards
+C 12 1.2 0.3 0.6 1.2 1.0 1.0 0.8 .833333333 1.0 0.0 0.0
+C 1.0 -.1885E-8 -1. 1.0 0.0 1.0 0.0 0.0
+C Extrema of output variables follow. Order and column positioning are the same as for the preceding time-step loop output.
+C Variable maxima : 0.3 0.6 1.2 1.0 1.0 0.8 .833333333 1.0 1.0 1.0
+C 1.0 .866025404 .866025404 1.0 1.0 1.0 0.5 0.5
+C Times of maxima : 0.0 0.0 1.2 0.0 1.2 0.0 1.0 0.1 0.2 0.2
+C 0.0 0.4 0.7 0.5 0.4 1.2 0.2 0.2
+C Variable minima : 0.3 0.6 0.0 1.0 -1. 0.8 0.0 0.0 0.0 0.0
+C 0.0 -1. -1. 0.0 0.0 -1. 0.0 0.0
+C Times of minima : 0.0 0.0 0.0 0.0 0.6 0.0 0.0 0.0 0.0 0.0
+C 0.2 0.9 1.2 0.0 0.0 0.5 0.0 0.0
+ PRINTER PLOT
+ 143 .4 0.0 1.2 DEV50IDEV53F { Axis limits: (-1.000, 0.866)
+BLANK card ending plot cards
+BEGIN NEW DATA CASE
+PRINTED NUMBER WIDTH, 10, 1, { Request maximum precision (for 9 output columns)
+C 2nd of 9 subcases of DC-21. Test TACS supplemental device types 57 and 58.
+C Printout explanation is as follows:
+C DEV1 = 1/S ON PLS1 UNTIL 0.010, THEN ZERO
+C DEV2 = 1/S ON PLS1 UNTIL 0.010, THEN RESET TO MINUS1, INIT=3.0
+C DEV3 = 1.0 ON PLS2 UNTIL 0.010, THEN ZERO
+C DEV4 = 5.0 ON PLS1 UNTIL 0.010, THEN ZERO
+C DEV5 = COUNTER ON PLUS1, == ISTEP
+ 0.001 0.016
+ 1 1 0 0 1
+TACS STAND ALONE
+ DUMMY +ZERO
+23PLS1 1.0 0.004 0.002
+23PLS2 1.0 0.008 0.004
+11CTRL 1.0 0.010
+98SW1 57+PLUS1
+ 0.002
+ 0.004
+ 0.005
+ 9999
+98SW2 57+PLUS1
+ 0.000
+ 0.003
+ 9999
+98DEV1 58+PLS1 0 0 1.0CTRL
+98DEV2 58+PLS1 0 0 1.0CTRL MINUS1
+98DEV3 58+PLS2 1.0 1.0 0.001CTRL
+98DEV4 58+PLS1 5.0 1.0 CTRL
+98DEV5 58+PLUS1 COUNTR
+C 26 August 2002, add a line from Orlando Hevia's EJEM58.DAT which had
+C illustrated an error using compiled TACS. This exercises S.N. 7323 in
+C TACSUP, which previously was in error yet was not being tested:
+98S_INTE58+SOURCE 1. 1.
+14SOURCE 0 1. 50. -1. 1.
+C End addition on 26 August 2002. The preceding source card was an
+C electric network source in Orlando's data, but then was passed to TACS
+C via a Type-90 source. Here, directly make it a TACS source.
+33SW1 SW2 PLS1 PLS2 CTRL DEV1 DEV2 DEV3 DEV4 DEV5 S_INTE
+77SW2 1.0
+77DEV2 3.0
+C Next 11 output variables belong to TACS (with "TACS" an internally-added upper name of pair).
+C Step Time TACS TACS TACS TACS TACS TACS TACS TACS TACS TACS TACS
+C SW1 SW2 PLS1 PLS2 CTRL DEV1 DEV2 DEV3 DEV4 DEV5 S_INTE
+C 0 0.0 0.0 1.0 0.0 0.0 0.0 0.0 3.0 0.0 0.0 0.0 0.0
+C 1 .1E-2 0.0 1.0 1.0 1.0 1.0 .5E-3 3.0005 .33333333 5.0 1.0 .47553E-3
+C 2 .002 1.0 1.0 0.0 1.0 1.0 .1E-2 3.001 .77777778 -.278E-15 2.0 .00135557
+C 3 .003 1.0 0.0 0.0 1.0 1.0 .1E-2 3.001 .92592593 .2776E-15 3.0 .00205397
+C 4 .004 0.0 0.0 1.0 0.0 1.0 .0015 3.0015 .64197531 5.0 4.0 .00250237
+BLANK card ending TACS data
+ PRINTER PLOT
+C 16 .016 1.0 0.0 1.0 1.0 0.0 0.0 -1. 0.0 0.0 16. -.0035024
+C Variable maxima : 1.0 1.0 1.0 1.0 1.0 .0045 3.0045 .92592593 5.0 16. .00265688
+C Times of maxima : .002 0.0 .1E-2 .1E-2 .1E-2 .009 .009 .003 .1E-2 .016 .005
+C Variable minima : 0.0 0.0 0.0 0.0 0.0 0.0 -1. 0.0 -.278E-15 0.0 -.0036569
+C Times of minima : 0.0 .003 0.0 0.0 0.0 0.0 .01 0.0 .002 0.0 .015
+ 144 3. 0.0 20. DEV2 DEV4 { Axis limits: (-1.000, 5.000)
+BLANK card ending plot cards
+BEGIN NEW DATA CASE
+C 3rd of 9 parts of DC-21. Test TACS supplemental device type 59 (derivative)
+C 27 March 2010, the following LARGEST PRINTED STEP NUMBER (LPSN) is being
+C added to illustrate suppression of the I7 step number after a while (step
+C number 38 in this case). Steps 39 and 40 will have no step number. The 7
+C columns thereby gained allow 17 columns for time (encode using F17.3)
+C 123456789012345678901234567890123456789012345678
+C NOTIME FMTIME
+C < E8.0 > < A6 >
+C LARGEST PRINTED STEP NUMBER 38 F17.3
+C The rules of preceding LPSN are unusual. Columns 33-40 give a step number
+C either in normal I8 format or alternative E8.0 format. Zero or blank
+C imply no LPSN use (to cancel preceding use). Minus one will suppress all
+C printing of step number including step zero. Columns 41 and 42 are unused
+C while 43-48 are reserved for an optional user-supplied format which might
+C be either E-field or F-field. Use of FORMAT ( F17.3 ) this way serves to
+C retain column alignment. Steps 39 and 40 will be encoded as 0.039 and 0.040
+C respectively. If columns 41-48 had been left blank, optimal encoding would
+C have been used, with the result being .039 and .04 respectively. Note
+C that in this case the decimal points would not be alligned. As for E-field,
+C a preceding implied 1P will make the leading digit significant. About the
+C new use of either E-format or I-format data, see also BENCHMARK DC-3. WSM
+C A free-format alternative also is available. Switch to this 14 July 2010:
+LARGEST PRINTED STEP NUMBER, 38, F17.3 { Same effect as preceding fixed-format
+PRINTED NUMBER WIDTH, 11, 1, { Restore default after exceptional 2nd subcase
+ 0.001 0.04
+ 1 1 0 0 1
+TACS STAND ALONE
+ DUMMY +ZERO
+14SIN1 1.0 25. -90.
+14COS1 1.0 25. 0.
+14SIN2 1.0 25. -90. -1.
+14COS2 1.0 25. 0. -1.
+23PLSE 1.0 0.02 0.01
+24RAMP 10.0 0.01 0.03
+98DEV1 59+SIN1
+98DEV2 59+SIN1
+98DEV3 59+PLSE
+98DEV4 59+RAMP
+98DEVA 59+SIN1
+98DEVB 59+SIN2
+98DEVC 59+SIN1
+98DEVD 59+SIN2
+98DEVE 59+COS1
+98DEVF 59+COS2
+33SIN1 COS2 PLSE RAMP DEV1 DEV2 DEV3 DEV4
+33DEVA DEVB DEVC DEVD DEVE DEVF
+77DEV2 1.0
+77DEVC 1.0
+77DEVD 1.0
+C Next 14 output variables belong to TACS (with "TACS" an internally
+C Step Time TACS TACS TACS TACS TACS
+C SIN1 COS2 PLSE RAMP DEV1
+C
+C TACS TACS TACS TACS
+C DEVC DEVD DEVE DEVF
+C 0 0.0 0.0 1.0 0.0 0.0 0.0
+C 1.0 1.0 0.0 0.0
+C 1 .1E-2 .156434465 .987688341 1.0 1.0 156.434465
+C 156.434465 156.434465 987.688341 -12.311659
+C 2 .002 .309016994 .951056516 1.0 2.0 152.582529
+C 152.582529 152.582529 -36.631824 -36.631824
+BLANK card ending TACS data
+ PRINTER PLOT
+C 0.039 -.15643447 .987688341 0.0 0.0 152.582529 152.582529 0.0 0.0 152.582529 152.582529
+C 152.582529 152.582529 36.6318243 36.6318243
+C 0.040 .43071E-14 1.0 1.0 0.0 156.434465 156.434465 1000. 0.0 156.434465 156.434465
+C 156.434465 156.434465 12.3116594 12.3116594
+C Variable maxima : 1.0 1.0 1.0 9.0 156.434465
+C 156.434465 156.434465 987.688341 156.434465
+C Times of maxima : .01 0.0 .1E-2 .029 .04
+C .04 .04 .1E-2 .03
+C Variable minima : -1. -1. 0.0 0.0 -156.43447
+C -156.43447 -156.43447 -156.43447 -156.43447
+C Times of minima : .03 .02 0.0 0.0 .02
+C .02 .02 .01 .01
+ 144 8. 0.0 40. DEVF DEV3 { Axis limits: (-1.000, 1.000)
+BLANK card ending plot cards
+BEGIN NEW DATA CASE
+C 4th of 9 in DC-21. Test TACS supplemental device types 60, 61, 62, and 63.
+LARGEST PRINTED STEP NUMBER 0 { Cancel use of preceding subcase
+ 0.001 0.08
+ 2 1 0 0 1
+TACS STAND ALONE
+ DUMMY +ZERO
+14SIN 1.0 25. -90.
+14COS 1.0 25. 0.
+14SIN0 8.0 25. -90.
+14SIN1 1.0 8.0 -90.
+14SIN2 0.5 24.0 -90.
+23PLS1 1.0 0.050 0.025 0.050
+23PLS2 1.0 0.025 0.015 0.050 0.075
+23PLS3 1.0 0.005 0.001 0.075
+98DEV1 60+MINUS1 +ZERO +PLUS1 -1.0 SIN PLUS1
+98DEV2 60+MINUS1 +ZERO +PLUS1 SIN
+98DEV3 60+ZERO +ZERO +PI 20. ISTEP
+98DEV4 61+MINUS1 +ZERO +PLUS1 +DELTAT -3. 222PI SIN0
+98CTRL = PLS1 + PLS2 + PLS3
+98TRCK 62+SIN1 +SIN2 CTRL
+98SMPL 62+SIN1 +SIN2 CTRL
+98PLOT = SIN1 + SIN2
+98MIN 63+SIN +COS -1.
+98MAX 63+SIN +COS +1.
+33SIN COS SIN0 DEV1 DEV2 DEV3 DEV4 MIN MAX
+33CTRL PLOT TRCK SMPL SIN1 SIN2 PLS1 PLS2 PLS3
+C Step Time TACS TACS TACS TACS TACS TACS
+C SIN COS SIN0 DEV1 DEV2 DEV3
+C
+C TACS TACS TACS TACS TACS TACS
+C PLOT TRCK SMPL SIN1 SIN2 PLS1
+C 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
+C 0.0 0.0 0.0 0.0 0.0 0.0
+C 2 .002 .309016994 .951056516 2.47213595 1.0 1.0 0.0
+C .248882506 .248882506 .125357113 .100361715 .148520791 1.0
+BLANK card ending TACS data
+C 80 .08 .85529E-14 1.0 .68423E-13 0.0 0.0 3.14159265
+C -1.0113901 -1.0113901 -1.0113901 -.77051324 -.24087684 0.0
+C Variable maxima : 1.0 1.0 8.0 1.0 1.0 3.14159265
+C 1.07581929 1.07581929 1.06331351 .999921044 .499960522 1.0
+C Times of maxima : .01 .04 .01 .1E-2 .1E-2 .021
+C .014 .014 .05 .031 .052 .1E-2
+C Variable minima : -1. -1. -8. -1. -1. 0.0
+C -1.0746121 -1.0633135 -1.0633135 -.77051324 -.49996052 0.0
+C Times of minima : .03 .02 .03 .021 .021 0.0
+C .076 .075 .075 .08 .073 0.0
+ PRINTER PLOT
+ 144 8. 0.0 80. PLOT TRCK { Axis limits: (-1.075, 1.076)
+BLANK card ending plot cards
+BEGIN NEW DATA CASE
+C 5th of 9 in DC-21. Test TACS supplemental device type 64 (min/max tracking)
+ 0.001 0.06
+ 2 1 0 0 1
+TACS STAND ALONE
+ DUMMY +ZERO
+14SIN1 1.0 50. -90.
+23PLS 1.0 0.02 0.001 -0.01
+24RMP 8.0 0.08
+11HLD 1.0 0.03
+98MXTR1 64+RMP +SIN1 +1.
+98MNTR2 64-RMP -SIN1 -1.
+98MNTR3 64+RMP +SIN1 -1. 100.PLS
+98MXTR4 64+RMP +SIN1 +1. HLD
+98PLOT = RMP + SIN1
+33PLOT PLS HLD MXTR1 MNTR2 MNTR3 MXTR4
+77MNTR3 100.
+C Next 7 output variables belong to TACS (with "TACS" an internally-added u
+C Step Time TACS TACS TACS TACS TACS TACS
+C PLOT PLS HLD MXTR1 MNTR2 MNTR3
+C 0 0.0 0.0 0.0 0.0 0.0 0.0 100.
+C 2 .002 .787785252 0.0 0.0 .787785252 -.78778525 .409016994
+BLANK card ending TACS data
+C 60 .06 6.0 0.0 1.0 6.0 -6. 4.44894348
+C Variable maxima : 6.0 1.0 1.0 6.0 0.0 100.
+C Times of maxima : .06 .01 .03 .06 0.0 0.0
+C Variable minima : 0.0 0.0 0.0 0.0 -6. .409016994
+C Times of minima : 0.0 0.0 0.0 0.0 .06 .1E-2
+ PRINTER PLOT
+ 144 6. 0.0 60. PLOT MXTR4 { Axis limits: (0.000, 6.000)
+BLANK card ending plot cards
+BEGIN NEW DATA CASE
+C 6th of 9 subcases of DC-21. Test the TACS supplemental device type 65
+C (accumulator/counter). Also, beginning 10 November 2002, add a
+C request for relative table sizing. This may not be very practical,
+C but it deserves to be illustrated. The proportions shown roughtly
+C correspond to default dimensioning, so the effect should be neglible:
+RELATIVE TACS DIMENSIONS
+ 11 15 7 7 3 8 21 28 1
+ 0.001 0.04
+ 2 1 0 0 1
+TACS STAND ALONE
+ DUMMY +ZERO
+14SIN1 1.0 25. -90.
+23PLS 1.0 0.02 0.01
+98ACC1 65+SIN1
+98ACC2 65+PLS
+98DEL1 54+PLS DELTAT
+98DRV = PLS - DEL1
+98RISE 60+ZERO +ZERO +PLUS1 DRV
+98ACC3 65+RISE
+98AVRG1 = ACC1 / ISTEP
+98AVRG2 = ACC2 / ISTEP
+33SIN1 PLS ACC1 ACC2 DEL1 DRV RISE ACC3 AVRG1 AVRG2
+C Next 10 output variables belong to TACS (with "TACS" an internally-adde
+C Step Time TACS TACS TACS TACS TACS TACS
+C SIN1 PLS ACC1 ACC2 DEL1 DRV
+C 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
+C 2 .002 .309016994 1.0 .465451459 2.0 1.0 0.0
+C 4 .004 .587785252 1.0 1.50722721 4.0 1.0 0.0
+BLANK card ending TACS data
+C 38 .038 -.30901699 0.0 .156434465 19. 0.0 0.0
+C 40 .04 .43071E-14 1.0 .43071E-14 20. 0.0 1.0
+C Variable maxima : 1.0 1.0 12.7062047 20. 1.0 1.0
+C Times of maxima : .01 .1E-2 .019 .04 .002 .1E-2
+C Variable minima : -1. 0.0 0.0 0.0 0.0 -1.
+C Times of minima : .03 0.0 0.0 0.0 0.0 .01
+ PRINTER PLOT
+ 144 4. 0.0 40. AVRG1 AVRG2 RISE { Axis limits: (0.000, 1.000)
+BLANK card ending plot cards
+BEGIN NEW DATA CASE
+C 7th of 9 subcases of DC-21. Test the TACS supplemental device type 69
+C which became available on 8 January 2003. The Type-68 TACS device is
+C not being illustrated here because DCNEW-25 shows realistic use. Type
+C 69 is for user-supplied source code as defined in SUBROUTINE DEVT69.
+C The illustration here corresponds to logic of the UTPF, which defines
+C just 2 simple functions: DEV69A = twice arg 1 plus arg 2
+C DEV69B = the square of arg 1
+PRINTED NUMBER WIDTH, 10, 2, { Request maximum precision (for 9 output columns)
+ 0.001 0.020
+ 1 1 0 0 1
+TACS STAND ALONE
+14SOURCE 1.0 50.0 -1.
+88ARG2 = -0.5 * SOURCE
+C The following 3 data cards are for Type-69 TACS devices, which first became
+C available on 8 January 2003. Columns 1-10 are fixed format with the same
+C rules as all other devices. Thereafter, data is free-format with one or
+C more blanks separating each input. First comes the A6 function name (here
+C we illustrate the 2 that are provided in SUBROUTINE DEVT69 of the UTPF).
+C Note that constant arguments are allowed:
+88USERA 69 DEV69A SOURCE ARG2 { Device type 69 is named USERA; 2 args follow
+88USERB 69 DEV69A SOURCE 0.1 { Device type 69 is named USERB; 2 args follow
+88USERC 69 DEV69B SOURCE { Device type 69 is named USERC; single arg follows
+88USERD = 2.0 * USERC
+88VALUE = 2.0 * SOURCE
+C Should a single data card not provide enough space for all inputs of a
+C Type-69 device, the addition of $$ anywhere on the right represents a
+C request for continuation on the following data card. Let's illustrate
+C this artificially. Note the following USERE should equal USERA. Also
+C note that more than a single blank is used to separate names on the
+C initial data card, and that the function name begins in column 11 (the
+C previous illustrations did not have this):
+88USERE 69DEV69A SOURCE $$ { Continuation mark can be anywhere on right
+ ARG2 { Inputs of a continuation line can begin as early as column 11
+C 27 January 2003, add 3rd function having 5 args and diagnostic print:
+88THREE = 3.0
+88USERF 69 DEV69C UNITY 2.0 THREE 4.0 5.0
+88USERG 69 DEV69C 1.0 2.0 THREE 4.0 5.0
+88USERH 69 DEV69C .1E1 2.E0 30.E-1 .4E+1 0.05E+2
+33VALUE USERB ARG2 USERA USERE USERC USERD SOURCEUSERF USERG USERH
+77USERA 1.5 { Initial condition on 1st of 2 function uses
+77VALUE 2.0 { Initial condition on signal that is close to 2nd function
+BLANK card ending TACS data
+ CALCOMP PLOT { Toggle plot mode to vector graphic (preceding was printer)
+ 144 2. 0.0 20. USERA USERD VALUE SOURCE
+BLANK card ending plot cards
+BEGIN NEW DATA CASE
+PRINTED NUMBER WIDTH, 12, 2, { Keep dT loop precision the same, but 2 blank separators
+C 8th of 9 subcases of DC-21. The first subcase illustrated the use of
+C Type-56 TACS devices, including the new MODELS SEEK option. But that
+C was without any MODELS. Now, 10 April 2011, we will demonstrate that
+C such use is possible when MODELS is present. So, take the source and
+C Type-56 device of the 1st subcase and add to them the matrix inversion
+C using MODELS of the 14th subcase of DC-68. There is no interaction
+C between the two types of modeling, of course. Because the time step
+C and ending time are as used for the Type-56 device, matrix inversion
+C will differ for all but the first use. Remember, the matrix depends on
+C using simulation time T, and this will differ. But the 10th step here
+C will be for 1 sec, so will coincide with the first step of DC-68. Thus
+C the 10th step here will have the same inverse as the 1st step of DC-68.
+C Rather than only one matrix inversion coinciding, two will. WSM.
+$PREFIX, [] { $INCLUDE files are located in same place as this main data file
+C Preceding line allows the SEEK file to be remote if this main data file is
+ 0.1 1.2 { Take 12 time steps exactly as was the case with subcase 1
+ 1 -1 { Suppress accumulation of plot points, which are unused
+TACS HYBRID { There will be a dummy electric network, too, as well as MODELS
+C 3456789012345678901234567890123456789012345678 -- Ruler for following optional
+C < File Name> IPRMDL KOMPAC miscellaneous data card :
+C TACS MISC. DATA dc21seek. 0 0
+C Omit TACS misc. data since MODELS will follow, and can define the same data
+14SOURCE 1.0.833333333
+88SEE56 56+SOURCE 45 MODELS SEEK
+33SOURCESEE56
+BLANK card that ends TACS data cards
+MODELS { Data for MODELS follows the preceding TACS data. Copy from DC-68
+C 3456789012345678901234567890123456789012345678 -- Ruler for following optional
+C < File Name> IPRMDL KOMPAC miscellaneous data card :
+MODELS MISC. DATA dc21seek. 0 0
+VAR a1, a2, a3, a4, a5, a6, a7, a8, a9
+MODEL invert FOREIGN invert {ixdata:1, ixin:9, ixout:9, ixvar:0}
+USE invert AS invert
+ DATA xdata[1]:=3 -- Order of the matrices involved (here, 3)
+ INPUT xin[1..9] := [ 1.0, 2.0, 3.0,
+ 4.0, 2.0, 5.0,
+ 6.0, 3.0, 2.0 ] + t
+ OUTPUT a1:=xout[1],a2:=xout[2],a3:=xout[3],
+ a4:=xout[4],a5:=xout[5],a6:=xout[6],
+ a7:=xout[7],a8:=xout[8],a9:=xout[9]
+ENDUSE
+RECORD
+ a1 AS a11
+ a2 AS a12
+C a3 AS a13 { DC-68 had more outputs, which we will not bother to show here
+C a4 AS a21 { DC-68 had more outputs, which we will not bother to show here
+C a5 AS a22 { DC-68 had more outputs, which we will not bother to show here
+C a6 AS a23 { DC-68 had more outputs, which we will not bother to show here
+C a7 AS a31 { DC-68 had more outputs, which we will not bother to show here
+ a8 AS a32
+ a9 as a33
+ENDMODELS
+C Electric network really is not used for anything. Define two series R-L-C:
+ GEN BUS1 15.
+ BUS1 2.9
+BLANK card terminates electric network branches
+BLANK card ends all switches
+C Finally, add a sinusoidal source to drive those dummy branches:
+14GEN 100. 50. 0.0 -1.
+BLANK card terminates electric network sources
+BLANK card ending node voltage request
+BLANK card ending plot cards
+BEGIN NEW DATA CASE
+C 9th of 9 subcases of DC-21. This is a variation of the preceding 8th
+C subcase. The Type-56 TACS data is similar but the matrix inversion of
+C MODELS will be replaced by the SEEK function of subcase # 15 of DC-68.
+C Thus both TACS and MODELS use SEEK. Both will load memory of List 20
+C from disk files DC68SExx.DAT where xx = 37 for TACS & 82 for MODELS.
+$PREFIX, [] { $INCLUDE files are located in same place as this main data file
+C Preceding line allows the SEEK files to be remote if this main data file is
+ 1.0 3.00 { Take 3 steps, from 1 second to 3 seconds.
+ 1 -1 { Print every step; do not bother saving points for plotting
+TACS HYBRID
+C 3456789012345678901234567890123456789012345678 -- Ruler for following optional
+C < File Name> IPRMDL KOMPAC miscellaneous data card :
+TACS MISC. DATA dc68seek. 0 0
+C About the preceding, note that here TACS will define the misc. data whereas
+C the preceding subcase did this using MODELS. Either has the same effect.
+C The user who wants to see diagnostic printout of SEEK can set IPRMDL = 9.
+C This would be no problem for Salford ATP, as the extra output would merely
+C be sent to the .DBG file. But for some other compilers, this would go
+C to the .LIS file, and would be unsightly (beware). With just 3 time
+C steps, however, the volume is easily tolerated.
+14SOURCE 1.0.833333333
+C Type-56 device allows MODELS "SEEK" : SEEK function # Key word--->
+88SEE37 56+TIMEX 37 MODELS SEEK
+33SEE37
+BLANK card that ends TACS data cards
+MODELS { Data for MODELS follows the preceding TACS data. Copy from DC-68
+MODEL SAMPLE
+VAR X,Y,Z
+FUNCTION seek FOREIGN seek {ixarg: 2}
+EXEC
+C The following three lines use SEEK function # 82, which is the same as #37.
+C 82 does have a couple of redundant interior points to be discarded, though:
+X:=SEEK(T, 82 )
+Y:=SQRT(X)*0.3
+Z:=SEEK(SQRT(X)*0.3, 82 )
+ENDEXEC
+ENDMODEL
+USE SAMPLE AS SAMPLE
+ENDUSE
+RECORD
+SAMPLE.X AS SEE82 -- This will send X to LUNIT6 output of ATP as variable SEE82
+SAMPLE.Y AS Y
+SAMPLE.Z AS Z
+ENDRECORD
+ENDMODELS
+C Electric network really is not used for anything. Define two series R-L-C:
+ GEN BUS1 15.
+ BUS1 2.9
+BLANK card terminates electric network branches
+BLANK card ends all switches
+C Finally, add a sinusoidal source to drive those dummy branches:
+14GEN 100. 50. 0.0 -1.
+BLANK card terminates electric network sources
+C Total network loss P-loss by summing injections = 0.000000000000E+00
+C 3 or more consecutive, identical Y has allowed the omission of 2 incoming (X,Y) points. The next line reflects this fact.
+C MODELS "SEEK" function # 82 involves 7 pairs of (X,Y). These are stored in List-20 SCONST cells 3 through 16.
+C Blank card ending requests for output variables. |BLANK card ending node voltage request
+C Column headings for the 4 EMTP output variables follow. These are divided among the 5 possible classes as follows ....
+C Next 1 output variables belong to TACS (with "TACS" an internally-added upper name of pair).
+C Next 3 output variables belong to MODELS (with "MODELS" an internally-added upper name of pair).
+C Column headings for the 4 EMTP output variables follow. These are divided among the 5 possible classes as follows ....
+C Next 1 output variables belong to TACS (with "TACS" an internally-added upper name of pair).
+C Next 3 output variables belong to MODELS (with "MODELS" an internally-added upper name of pair).
+C Step Time TACS MODELS MODELS MODELS
+C SEE37 SEE82 Y Z
+C 0 0.0 0.0 69. 2.49198716 72.6314093
+C TACS "SEEK" function # 37 involves 7 pairs of (X,Y). These are stored in List-20 SCONST cells 19 through 32.
+C 1 1.0 59.5 59.5 2.31408729 64.4480155
+C 2 2.0 50. 50. 2.12132034 55.5807358
+C 3 3.0 96. 96. 2.93938769 93.2118338
+BLANK card ending node voltage request
+C Note the preceding messages that report loading of SEEK functions # 82 & 37:
+C MODELS "SEEK" function # 82 involves 7 pairs of (X,Y). ... cells 3 through 16.
+C TACS "SEEK" function # 37 involves 7 pairs of (X,Y). .. cells 19 through 32.
+C Each requires 14 cells for the 7 pairs of (X, Y) plus two extras (constant
+C overhead) for a total of 16. Because initialization of MODELS occurs before
+C the dT loop is entered, the message for MODELS appears first and it is the
+C use of MODELS that grabs the first 16 cells. TACS use of SEEK first occurs
+C on time step 1, so it follows. TACS loads the following 16 cells of List
+C 20 (cells 17 thru 32). Were the TACS use to be changed from # 37 to # 82,
+C there would be no second message (for TACS). In this case, TACS would be
+C sharing the List-20 storage that was established by MODELS.
+BLANK card ending plot cards
+BEGIN NEW DATA CASE
+BLANK
|