BEGIN NEW DATA CASE C BENCHMARK DCPR-6 C Test of Type-99 pseudo-nonlinear resistance. 1-phase line energization. PRINTED NUMBER WIDTH, 13, 2, { Request maximum precision (for 8 output columns) DIAGNOSTIC 0 9 9 9 9 9 0 9 9 9 9 9 9 9 9 9 9 9 9 .000200 .020 60. 60. 1 1 1 1 1 -1 2 -1 5 5 20 20 REC 100. 3 -1SEND REC 0.3 0.4 12.6 100. 99REC 5.0 2 1 1.0 100. 2.0 200.1 9999 BLANK card ending branch cards GEN SEND .0003 1.0 { Switch that energizes line on 2nd step BLANK card ending switch cards 14GEN 100. 60. { Source not present in steady state, note BLANK card ending source cards C Step Time REC REC SEND GEN REC C TERRA TERRA C 0 0.0 0.0 0.0 0.0 0.0 0.0 C 1 .2E-3 0.0 0.0 0.0 99.71589003 0.0 1 C 2 .4E-3 0.0 0.0 0.0 98.86517447 0.0 C 3 .6E-3 0.0 0.0 97.45268728 97.45268728 0.0 C 4 .8E-3 0.0 0.0 95.48645447 95.48645447 0.0 C 5 .001 1.412558111 1.412558111 92.97764859 92.97764859 0.0 C " " begins operation on segment 2 at time T = 1.20000000E-03 sec. C 10 .002 31.57766457 31.57766457 72.89686274 72.89686274 .3157766457 C " " begins operation on segment 0 at time T = 1.38000000E-02 sec. C " " begins operation on segment 2 at time T = 1.40000000E-02 sec. C 80 .016 42.14983507 42.14983507 96.85831611 96.85831611 .4214983507 C 100 .02 40.44541516 40.44541516 30.90169944 30.90169944 .4044541516 C Variable max : 62.79749241 62.79749241 99.96841893 99.96841893 .5668106247 C Times of max : .0012 .0012 .0166 .0166 .018 C Variable min : -56.7406992 -56.7406992 -99.9684189 -99.9684189 -.567406992 C Times of min : .0096 .0096 .0084 .0084 .0096 PRINTER PLOT 194 2. 0.0 20. REC { Axis limits : (-5.674, 5.668) BLANK card ending plot cards BEGIN NEW DATA CASE BLANK