BEGIN NEW DATA CASE C BENCHMARK DCNEW-28 C 1st of ?? subcases illustrates creation of new C-like .PL4 file that was C inspired by Massimo Ceraolo of the University of Pisa in Italy. The date C of addition is 11 March 1999, and mention should be found in later issues C of the newsletter. There are no dynamics. The network is resistive, and C all voltages and currents are sinusoidal. An attempt has been made to C involve different types of variables: 1 branch voltage first, then a power, C then two node voltages, then a branch current, then energy, and finally, C a TACS signal (also power). The new C-like format should be better than C the old for concurrent, SPY-like plotting. $BEGIN PL4 COMMENTS C Massimo Ceraolo of the University C of Pisa in Italy can plot SPY-like. $END PL4 COMMENTS PRINTED NUMBER WIDTH, 9, 2, $DEPOSIT, NEWPL4=2 { Special value that characterizes new C-like .PL4 file type .0005 .020 1 1 1 0 0 0 0 2 TACS HYBRID 90GEN { Electric network source voltage 91SWIT { Electric network switch current 99VOLT = 0.5 * GEN { Half the source voltage = branch voltage 99POWER = VOLT * SWIT { Branch power consumption = v(t) * i(t) 33POWER { Output branch power BLANK card ending all TACS data SWIT SEND 1.0 2 SEND 1.0 4 BLANK card ending branch cards GEN SWIT MEASURING 1 BLANK card ending switch cards 14GEN 100. 50. BLANK card ending source cards SWIT SEND C First 4 output variables are electric-network voltage differences (upper voltage minus lower voltage); C Next 2 output variables are branch currents (flowing from the upper node to the lower node); C Next 1 output variables belong to TACS (with "TACS" an internally-added upper name of pair). C Branch power consumption (power flow, if a switch) is treated like a branch voltage for this grouping (1 variables); C Branch energy consumption (energy flow, if a switch) is treated like a branch current for this grouping (1 variables). C Step Time SWIT SEND SWIT SEND GEN SEND TACS C SEND TERRA SWIT TERRA POWER C *** Switch "GEN " to "SWIT " closed before 0.00000000E+00 sec. C 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C 1 .5E-3 49.3844 2438.82 98.7688 49.3844 49.3844 .609705 2438.82 C 2 .1E-2 47.5528 2261.27 95.1057 47.5528 47.5528 1.78473 2261.27 C 3 .0015 44.5503 1984.73 89.1007 44.5503 44.5503 2.84623 1984.73 C .PL4 type code: 8 6 4 4 9 7 2 C Variable class: V-bran Power V-node V-node I-bran Energy TACS BLANK card ending requests for node voltage output PRINTER PLOT 194 2. 0.0 20. SEND GEN SWIT BLANK card ending plot cards BEGIN NEW DATA CASE BLANK