BEGIN NEW DATA CASE C BENCHMARK DC-65 C The beginning case-marker card and the present comment cards represent C an exception that must be carefully remembered. They are an exception C to the rule that nothing must precede the definitions of argum. vectors C KARD, KARG, KBEG, KEND, and KTEX. Well, only here, in and around KARD C lines is such exceptional input allowed. Beginning with the very first C KARG card and ending with the last KTEX card, there must be nothing C but numbers. Now, about the data case, which was produced (except for C these exceptional cards at the top!) by the 3rd subcase of DC-36, which C uses "DATA BASE MODULE". There is a single argument, which is TMAX, C the end-time of the study. The basic problem is that of DC-4, which C has been modified by the removal of connectivity and phasor printout. C To see 42 steps, key "file_name" as follows: "dc65. , 0.42" (note C 3 or more blanks preceding the comma are required for automatic "dat". KARD 2 KARG 1 KBEG 13 KEND 16 KTEX 0 PRINTED NUMBER WIDTH, 13, 2, { Request maximum precision (for 8 output columns) .010 TMAX 1 1 0 3 1 -1 5 5 20 20 BRANCH NAME:First { Even though name could go on next card, use this instead GEN TRAN 5.0 5.E4 3 TRAN NAME R-mag 1.E4 93TRAN NAME Magnet .005 30. 3 0.0 0.0 { 1st point being origin is request to reflect .005 30. .01 40. .02 45. .10 50. 5.0 100. 9999 TRAN LOADG 255. 5.E4 3 C Note: original fixed-format card (next comment) converted to free-format: C LOADG 1.E-6 0,LOADG, , , , 1.E-6, 0.0, 0.0, , , , , , BLANK card ending program branch cards. BLANK card terminating program switch cards (none, for this case) 14GEN 70. .1591549 -1. BLANK card terminating program source cards. C Total network loss P-loss by summing injections = 8.286714400785E+00 C Inject: GEN 70. 70. .23676326859385 .25769284993889 8.2867144007848 C Inject: 0.0 0.0 -.1017288531066 -23.2514964 3.5605098587304 C ---- Initial flux of coil "TRAN " to " " = -1.13295190E+01 C Step Time GEN TRAN TRAN GEN TRAN C TRAN TERRA LOADG C 0 0.0 6.270257621 63.72974238 63.72974215 70. 63.72974238 C 1 .01 6.156651781 63.83984825 63.83984802 69.99650003 63.83984825 GEN TRAN BLANK card ending program output-variable requests. C 42 .42 1.105583309 62.81064576 62.81064551 63.91622907 62.81064576 C Variable maxima : 6.270257621 64.72841365 64.7284134 70. 64.72841365 C Times of maxima : 0.0 .18 .18 0.0 .18 C Variable minima : 1.105583309 62.81064576 62.81064551 63.91622907 62.81064576 C Times of minima : .42 .42 .42 .42 .42 PRINTER PLOT $WIDTH, 79, { Switch to narrow output to minimiz output (rest is of no interest) BLANK card ending all plot cards BEGIN NEW DATA CASE BLANK