From b18347ffc9db9641e215995edea1c04c363b2bdf Mon Sep 17 00:00:00 2001 From: Angelo Rossi Date: Wed, 21 Jun 2023 12:04:16 +0000 Subject: Initial commit. --- benchmarks/dcp1.dat | 70 +++++++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 70 insertions(+) create mode 100644 benchmarks/dcp1.dat (limited to 'benchmarks/dcp1.dat') diff --git a/benchmarks/dcp1.dat b/benchmarks/dcp1.dat new file mode 100644 index 0000000..39b1034 --- /dev/null +++ b/benchmarks/dcp1.dat @@ -0,0 +1,70 @@ +BEGIN NEW DATA CASE +C BENCHMARK DCPR-1 +C Test of 1-phase constant-parameter line. One switch is permanently +C closed. No transients. Plot of receiving end voltage is sinusoid. +DIAGNOSTIC 0 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 +PRINTED NUMBER WIDTH, 13, 2, { Request maximum precision (for 8 output columns) + .000100 .020 60. 60. + 1 1 1 1 1 -1 + 2 -1 5 5 20 20 + REC .001 { Near short at receiving end to ground } 3 +-1SEND REC 0.3 0.4 12.6 100. { 1-phase distributed line +BLANK card ending branch cards + GEN SEND -1.0 1.0 { Permanently closed switch at sending end +BLANK card ending switch cards +14GEN 100. 60. { 60-Hz phasor solution } -1. +BLANK card ending source cards +C Total network loss P-loss by summing injections = 5.992836086590E+01 +C GEN +C SEND 100. 100. 1.1985672173179 1.9672525544427 +C 0.0 0.0 -1.559974114699 -52.4640241 +C Step Time REC REC SEND GEN REC +C TERRA TERRA +C 0 0.0 .001198266 .001198266 100. 100. 1.198266 +C 1 .1E-3 .0012585558 .0012585558 99.92894726 99.92894726 1.258555833 + 1 +C 200 .02 .0019138946 .0019138946 30.90169944 30.90169944 1.913894577 +C Variable max : .0020173699 .0020173699 100. 100. 2.017369917 +C Times of max : .0025 .0025 0.0 0.0 .0025 +C Variable min : -.002017453 -.002017453 -99.9921044 -99.9921044 -2.01745286 +C Times of min : .0108 .0108 .0083 .0083 .0108 + PRINTER PLOT + 194 4. 0.0 20. REC { Axis limits : (-2.017, 2.017) +BLANK card ending plot cards +BEGIN NEW DATA CASE +C 2nd subcase involves use of trapped-charge source to initialize +C an initially-disconnected single-phase line. Later, energize the +C line by switch closure at 3 msec. The data was supplied by Dipl. +C Ing. Bernd Stein of FGH (Mannheim, Germany) during April of 1986. +PRINTED NUMBER WIDTH, 13, 2, { Request maximum precision (for 8 output columns) +DIAGNOSTIC 0 9 0 9 9 9 0 9 9 9 0 9 9 9 9 9 9 9 9 +ALTERNATE DIAGNOSTIC PRINTOUT, 0, 0, 0, 0, { Need for 2nd or later subcase only + .000100 .020 { Unlike 1st of 2 subcases, here XOPT = COPT = 0 + 1 1 0 1 1 -1 + 2 -1 5 5 20 20 { Switch to alternate on step 2 + GEN SWITCH 39.8 + SWITCH 1000. +-1SEND REC .3055 5.819 .0121 138. +BLANK card ending branch cards + SEND SWITCH .003 1.0 { Transient begins at 3 msec with closure +BLANK card ending switch cards +C 1 2 3 4 5 6 7 8 +C 78901234567890123456789012345678901234567890123456789012345678901234567890 +14GEN 100. 60. -1.0 +14SEND -1 -100. .001 { Trapped-charge source } 5432. +C End multiple-frequency phasor solution data. The first source is a regular +C 60-Hertz generator, whereas the second has f = 1/1000 Hz for trapped charge +BLANK card ending source cards +C Total network loss P-loss by summing injections = 4.998874616296E+00 +C Last gen: SEND -100. 100. -.17408297E-12 .10491662826E-5 .8704148513E-11 +C Last gen: 0.0 180.0 -.1049166283E-5 -90.0000095 -.5245831413E-4 +C Step Time REC SEND SWITCH GEN +C 0 0.0 -100. -100. 99.97749233 100. +C 1 .1E-3 -100. -100. 99.96299489 99.92894726 +C 2 .2E-3 -100. -100. 99.80645119 99.71589003 + 1 { Request for the output of all four node voltages +C 200 .02 138.2909745 45.09406184 45.09406184 30.90169944 + 144 2. 0.0 20. SEND REC { Axis limits : (-2.510, 2.052) +BLANK card ending plot cards +BEGIN NEW DATA CASE +BLANK -- cgit v1.2.3