From b18347ffc9db9641e215995edea1c04c363b2bdf Mon Sep 17 00:00:00 2001 From: Angelo Rossi Date: Wed, 21 Jun 2023 12:04:16 +0000 Subject: Initial commit. --- benchmarks/dc51.dat | 753 ++++++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 753 insertions(+) create mode 100644 benchmarks/dc51.dat (limited to 'benchmarks/dc51.dat') diff --git a/benchmarks/dc51.dat b/benchmarks/dc51.dat new file mode 100644 index 0000000..2b32ac2 --- /dev/null +++ b/benchmarks/dc51.dat @@ -0,0 +1,753 @@ +BEGIN NEW DATA CASE +C BENCHMARK DC-51 +C "FREQUENCY SCAN" use, with subsequent plotting of phasors vs. frequency +C This test cases uses uniform spacing; See DC-52 for geometric spacing. +C Because IOUTLP = 2, the solutions for step numbers 3 and 5 are omitted. +C 1st of 3 data subcases (2 LINE MODEL FREQUENCY SCAN, LMFS, cases follow) +FREQUENCY SCAN, 60., 20., 130., 0, { 60 < f < 130 Hz in 20-Hz increments + 0.1 0.0 + 2 1 1 { IOUTLP (cols. 1-8) only prints every other point +C Note col-80 punch of "1" on following branch to output current. This was +C added in March of 1998 when original limitation to node volt was removed. +C In the output, this current should be the same as node voltage at CUR. +C The two quadruplets will be found side by side, ending the output vector. + LOAD MID .99 1.0 1 +C The following is a sampling resistor to produce a node voltage that is +C proportional to branch current. Note 1.0 = .99 + .01 (next card): + MID .01 +C The following is a measurement transformer. It is used to produce a +C node voltage (node "CUR") that is proportional to the branch current +C of interest. For minimum error, leakage impedance should, of course, +C be small. Magnetizing impedance is infinite. The turns ratio equals +C the resistance of sampling resistor. See end Sec. 1.0G3 Rule Book. + TRANSFORMER TRAN + 9999 + 1MID .0005 1.0 + 2CUR .001 100. +BLANK card ending branches +BLANK card ending (here, non-existent) switches +C The following request for complete output (rather than the default choice +C of magnitude only) is read as part of source data, but it must precede the +C first source. This is for FS use (HFS allows it anywhere among sources). + BOTH POLAR AND RECTANGULAR { Request for (in order): mag, angle, real, imag +C Preceding is one of 3 alternatives. The other two are, after commented: +C POLAR OUTPUT VARIABLES { 2nd of 3 alternatives for output gives mag, angle +C RECTANGULAR OUTPUT VARIABLES { 3rd of 3 alternative outputs gives real, imag +14LOAD 100. 60. -1. +BLANK card ending sources +C Column headings for the 5 output variables follow. These are divided ... +C First 4 output variables are electric-network voltage differences (upper voltage minus lower voltage); +C Next 1 output variables are branch currents (flowing from the upper node to the lower node); +C For each variable, magnitude is 1st, angle is 2nd, real part is 3rd, and imaginary is 4th. All 4 are labeled identically, note. +C Step F [Hz] LOAD LOAD LOAD LOAD MID MID MID MID TRAN TRAN +C TERRA TERRA TERRA TERRA +C +C TRAN TRAN CUR CUR CUR CUR LOAD LOAD LOAD LOAD +C TERRA TERRA TERRA TERRA MID MID MID MID +C 1 60. 100. 0.0 100. 0.0 .93571522 -20.655997 .875562973 -.33007946 .93571522 -20.655997 +C .875562973 -.33007946 93.571522 -20.655997 87.5562973 -33.007946 93.571522 -20.655997 87.5562973 -33.007946 +C The preceding agrees with what existed for many years prior to March of 1998: +C mag:LOAD angle:LOAD mag:MID angle:MID mag:TRAN angle:TRAN mag:CUR angle:CUR +C real:LOAD imag:LOAD real:MID imag:MID real:TRAN imag:TRAN real:CUR imag:CUR +C ----- Output vector for step number 1. Frequency = 6.00000000E+01 Hz. +C 1.0000000E+02 0.0000000E+00 9.3571522E-01 -2.0655997E+01 9.3571522E-01 -2.0655997E+01 9.3571522E+01 -2.0655997E+01 +C 1.0000000E+02 0.0000000E+00 8.7556297E-01 -3.3007946E-01 8.7556297E-01 -3.3007946E-01 8.7556297E+01 -3.3007946E+01 +-5LOAD { -5 ==> 2A6 name pairs for voltage differences (branch V) + MID TRAN { 0 ==> Request for the output of these node voltages +-5CUR { -5 ==> 2A6 name pairs for voltage differences (branch V) +BLANK card ending output requests +C Printout for remaining steps follows. Note steps 2 and 4 are missing (IOUT=2) +C 3 100. 100. 0.0 100. 0.0 .846733016 -32.141908 .7169568 -.45047724 .846733016 -32.141908 +C .7169568 -.45047724 84.6733016 -32.141908 71.69568 -45.047724 84.6733016 -32.141908 71.69568 -45.047724 +C 5 140. 100. 0.0 100. 0.0 .750845344 -41.336343 .563768731 -.49591688 .750845344 -41.336343 +C .563768731 -.49591688 75.0845344 -41.336343 56.3768731 -49.591688 75.0845344 -41.336343 56.3768731 -49.591688 + PRINTER PLOT + F-SCAN COMPONENTS MAG ANGLE { Access "mag" and "angle" next +C 19630. 60.150. CUR mag CUR angle { Axis limits: (-4.134, 9.357) + 18630. 60.150. CUR CUR { Node voltage at CUR is branch voltage to ground +C The following card involves a deliberate spelling error in order to +C show how this results in rejection of the card: + F-SCAN COMPONENTS REAL IMxx { Access "real" and "imag" next + F-SCAN COMPONENTS REAL IMAG { Access "real" and "imag" next +C 19630. 60.150. CUR real CUR imag { Axis limits: (-4.959, 8.756) + 18630. 60.150. CUR CUR { Node voltage at CUR is branch voltage to ground +BLANK card ending plot cards +BEGIN NEW DATA CASE +C 2nd of 3 data subcases. +C Illustration of LINE MODEL FREQUENCY SCAN (LMFS). For background of this +C feature that was first available in ATP at the end of March, 1992, see the +C story that appeared in the April, 1992, issue of Can/Am EMTP News. This new +C feature is to compare any "line model" with the exact Pi-model of a single +C segment of overhead line over an arbitrary range of frequencies. The user +C instructions are attached at the end of this test case. +C In the current case a single-circuit line generated by JMARTI SETUP is to +C be tested. +C DISK PLOT DATA { Has no effect as explained in Can/Am EMTP News of April, 1992 +C Warning! This is degenerate use for initial testing only. +C Note following card will produce scan of 2 points only: +C LINE MODEL FREQUENCY SCAN, 60, , 599.9, 1, , , { f-begin, f-end, points/decade +LINE MODEL FREQUENCY SCAN, 60, , 599.9, 1, , , First + 40.E-6 -.0600 60. + 1 1 0 0 0 0 0 2 +C IOUT KSSOUT ICAT +$INCLUDE, []dc51fs3.dat +$INCLUDE, []dc51fs3z.dat, JDA###, LMA###, JDB###, LMB###, JDC###, LMC###, +C []dc51fs3p.dat +C Unused! ----- 2nd of 2 file names is not used for this single-circuit case +C Observation about the following is added 21 November 2003. Normally, a +C LINE CONSTANTS declaration would begin the data since it is this choice +C (not CC or CP) that is desired. But when LMFS began, LC was the +C only choice. It seems to be the default choice. Lack of the declaration +C here no longer is recommended, but it does demonstrate the default choice: +C LINE CONSTANTS { Activate this comment to prove that the solution is unchanged + 1.3636 .05215 4 1.602 -20.75 50. 50. + 1.3636 .05215 4 1.602 -19.25 50. 50. + 2.3636 .05215 4 1.602 - 0.75 77.5 77.5 + 2.3636 .05215 4 1.602 0.75 77.5 77.5 + 3.3636 .05215 4 1.602 19.25 50. 50. + 3.3636 .05215 4 1.602 20.75 50. 50. + 0.5 2.61 4 0.386 -12.9 98.5 98.5 + 0.5 2.61 4 0.386 12.9 98.5 98.5 +BLANK card ennds conductor cards of "LINE CONSTANTS" data +100. 5000. 1 138. 1 1 +BLANK card ending frequency cards of "LINE CONSTANTS" data +BLANK card ending batch-mode plot cards +BEGIN NEW DATA CASE +C 3rd of 3 data subcases illustrates LINE MODEL FREQUENCY SCAN (LMFS) for +C an untransposed double-circuit line generated by JMARTI SETUP. +C DISK PLOT DATA { Has no effect as explained in Can/Am EMTP News of April, 1992 +C LINE MODEL FREQUENCY SCAN, 6, , 60000, 10, , , { f-begin, f-end, points/decade +C Preceding free-format alternative was used successfully for more than a +C decade. 2 September 2003, replace it by this fixed-format alternative: +C f-begin del-f f-end #/dec FUNDFS +LINE MODEL FREQUENCY SCAN 6.0 0.0 6.E4 10 + 40.E-6 -.0600 60. 1.E-15 + 1 1 0 0 0 0 0 2 +C IOUT KSSOUT ICAT +$INCLUDE, []dc51fs6.dat { 1st of 2 $INCLUDE contains line section to be tested +$INCLUDE, []dc51fs6z.dat,MR02A# ,MR04A# ,MR02B# ,MR04B# ,MR02C# ,MR04C#, $$ +C MR02D# ,MR04D# ,MR02E# ,MR04E# ,MR02F# ,MR04F# +C []dc51fs6p.dat +C []dc51fs6m.dat +C Raw LINE CONSTANTS data for the overhead transmission line being considered: + 1.4138 .0497 4 1.603 -15. 52.0 A1-1 + 1.4138 .0497 4 1.603 -16.06 53.06 A1-2 + 1.4138 .0497 4 1.603 -13.94 53.06 A1-3 + 2.4138 .0497 4 1.603 -25. 83.0 B1-1 + 2.4138 .0497 4 1.603 -26.06 84.06 B1-2 + 2.4138 .0497 4 1.603 -23.94 84.06 B1-3 + 3.4138 .0497 4 1.603 -15. 114.0 C1-1 + 3.4138 .0497 4 1.603 -16.06 115.06 C1-2 + 3.4138 .0497 4 1.603 -13.94 115.06 C1-3 + 4.4138 .0497 4 1.603 15. 114.0 A2-1 + 4.4138 .0497 4 1.603 13.94 115.06 A2-2 + 4.4138 .0497 4 1.603 16.06 115.06 A2-3 + 5.4138 .0497 4 1.603 25. 83.0 B2-1 + 5.4138 .0497 4 1.603 23.94 84.06 B2-2 + 5.4138 .0497 4 1.603 26.06 84.06 B2-3 + 6.4138 .0497 4 1.603 15. 52.0 C2-1 + 6.4138 .0497 4 1.603 13.94 53.06 C2-2 + 6.4138 .0497 4 1.603 16.06 53.06 C2-3 + 0.5 3.56 4 .495 -7.0 150.7 OHGW-L + 0.5 3.56 4 .495 7.0 150.7 OHGW-R +BLANK CARD ENDING CONDUCTOR CARDS OF "LINE CONSTANTS" CASE + 100. .001 1 53.00 1 1 +C RHO ] [FCAR] [ DIST ] S T +BLANK card ending frequency cards of "LINE CONSTANTS" data + PRINTER PLOT + 186 .5 0.0 5.0 GENIA MAG Marti Section Z in Ohms + 196 .5 0.0 5.0 GENIA MAG Equivalent Pi Z in Ohms + 196 .5 0.0 5.0 GENIB % MAG Error Percent +BLANK card ending batch-mode (CalComp) plot cards +BEGIN NEW DATA CASE +BLANK +BEGIN NEW DATA CASE +BLANK +EOF { Instruct EMTP input code to ignore all following records of disk file + + + + + INSTRUCTIONS FOR USING "LINE MODEL FREQUENCY SCAN (LMFS)" + + + + This is a new feature in the EMTP to compare any "line model" with +the exact Pi-model of a single segment of overhead line over an arbitrary +range of frequencies. The "line model" that is being tested can be any +combination of linear branches, such as lumped elements, lines (constant +distributed parameters, frequency-dependent representation of any type), +coupled R-L elements, etc. + + Set up an EMTP simulation data case similar to that of a "FREQUENCY SCAN" +(ATP Rule Book, pp. II-18 to II-21 ) as follows: + + (1) Use a new special request card: LINE MODEL FREQUENCY SCAN (or LMFS). + The data fields and their format on this card are the same as those for + the regular "FREQUENCY SCAN" case: FMIMFS, DELFFS, FMAXFS, NPD. Leave + the data field for DeltaF blank, and enter the number of points per + decade for the logarithmic (geometric) spacing as NPD. FMIMFS and + FMAXFS are the beginning and the ending frequencies respectively. + + (2) Input the misc. data cards. + + (3) Input the branch cards for "line model" to be tested. + + (4) Input the appropriate generic data files which consist of the needed + branch cards and source cards by using $INCLUDE. Also required on + this card are the names of sending end and receiving end of each + phase of the line being tested. Eight generic data files for 3-, + 6- and 9-phase lines are provided along with the EMTP. They are + called "linescan#?.brn". "#" is the number of phases of the test + line. "?" is either z (zero-sequence), or p (positive-sequence), or + m (mutual-coupling). E.g., linescan6z.brn consists of the needed + branch cards and source cards for a "6"-phase "Z"ero-sequence + impedance test. Following is an example of the data cards for the + generic files which are needed for a 6-phase line LMFS case: + + Col. 79-80 +$INCLUDE,linescanz6.brn,MR02A# ,MR04A# ,MR02B# ,MR04B# ,MR02C# ,MR04C#, $$ +C MR02D# ,MR04D# ,MR02E# ,MR04E# ,MR02F# ,MR04F# +C linescanp6.brn +C linescanm6.brn + + Note that 12 node names are needed for a 6-phase line: MR02A and + MR04A are names of sending end and receiving end of the first phase + respectively, etc. "$$" in columns 79-80 indicate there is a + continuation card following the current $INCLUDE card. "C linescanp6.brn" + card provides the name of the file that EMTP can generate the needed + branch and source cards for the positive-sequence impedance test case; + and "C linescanm6.brn" provides information for generating mutual- + coupling impedance test case. One does not need the latter data card if + the test line is a single circuit. + + (5) Input the geometry data of a single segment of overhead line. Prepare + this line geometry data just like one does for the standard "LINE CONSTANTS" + data except only ONE frequency card is needed. This frequency card needs + the following data: RHO (earth resistivity), FCAR (Carson accuracy), + DIST (length of the line), ISEG (segmentation option), MODAL + (transposition of the line). End this group of cards with a BLANK + card ending frequency card. + + (6) Input optional plot card(s). E. g., + + PRINTER PLOT + 186 .2 0.0 5.0 GENIA MAG + 196 .2 0.0 5.0 GENIB % MAG + + Like the "FREQUENCY SCAN" cases, the plotting of the node voltage output + variables are given the type of branch quantities. The results of the + tested line model are treated as branch voltages ("8" in column 4), those + of the exact Pi-model are treated as branch current, so are the percentage + errors ("9" in column 4.) + + (7) Input the following three cards to end the data: + + BLANK CARD ENDING PLOT REQUESTS + BEGIN NEW DATA CASE + BLANK + + + + Three frequency scan cases are run and three output files are generated +with this single set of data to give the zero-sequence, positive-sequence, +and mutual (if multiple circuits) impedance check for the tested line model. + + The line printer output includes tabulation of results of the requested +node voltage output variables for the tested line model, for the exact Pi- +model, and the percentage errors. Using IOUT (misc. data card) to control +the frequency of this tabulation. Tabulation after 100 entries will be +truncated. Be careful with input of KSSOUT on the misc. data card. + + Like the "FREQUENCY SCAN" cases, the plotting of the node voltage output +variables are given the type of branch quantities. The results of the tested +line model are treated as branch voltages, those of the exact Pi-model are +treated as branch current, so are the percentage errors. + + If one wants to plot all the output variables, simply enter "ALL" to +the prompt: + + SEND NODE NAME & OPT. A24 DESCR. OR END ( ) :ALL + +then, provide information of number of phases and kind of impedance test at +the prompt: + + SEND A2 FILE SPECIFICATION:3P + +where "3" means 3-phase circuit, "P" means ploting of the results of +Positive-sequence impedance test. TPPLOT at this point will automatically +attach the appropriate pre-existing, user-controlled, plot data file +LMPLT3P.DAT (i.e. one of the LMPLT##.DAT files), and complete the whole +set of postscript output. In other words, the nodes specified in the +LMPLT##.DAT defines what user means by "ALL". + + + Tsu-huei Liu + March 24, 1992 + + +Solution of DC51.LIS : +--------------------- + + --- Pass 1. Card = 19. Ready to open $INCLUDE = dc51fs3.dat + --- Pass 1. Card = 121. Ready to open $INCLUDE = dc51fs3z.dat +Alternative Transients Program (ATP), Salford 80386 translation. All rights reserved by Can/Am user group of Portland, Oregon, USA. + Date (dd-mth-yy) and time of day (hh.mm.ss) = 30-Jul-93 09.55.41 Name of disk plot file, if any, is D:37300955.pl4 +Consult the 800-page ATP Rule Book of the Can/Am EMTP User Group in Portland, Oregon, USA. Program is no older than July, 1992. +Total size of LABCOM tables = 227363 INTEGER words. VARDIM List Sizes follow : 752 900 1500 150 7500 120 + 2100 5250 225 480 150 150 15000 60 10800 120 12 15 4800 1980 300 450 12000 9 1200 252 4 9600 +--------------------------------------------------+-------------------------------------------------------------------------------- +Descriptive interpretation of input data cards. | Input data card images are shown below, all 80 columns, character by character + 0 1 2 3 4 5 6 7 8 + 012345678901234567890123456789012345678901234567890123456789012345678901234567890 +--------------------------------------------------+-------------------------------------------------------------------------------- +Marker card preceding new EMTP data case. |BEGIN NEW DATA CASE +Comment card. KOMPAR = 1. |C 2nd of 3 data subcases. +Comment card. KOMPAR = 1. |C Illustration of LINE MODEL FREQUENCY SCAN (LMFS). For background of this +Comment card. KOMPAR = 1. |C feature that was first available in ATP at the end of March, 1992, see the + < < < Etc. (section removed) > > > +Blank card terminating frequency cards. |BLANK card ending frequency cards of "LINE CONSTANTS" data + 1) Freq [Hz] = 6.0000000E+01 Total network loss = 7.284400782006E+01 + 2) Freq [Hz] = 6.0000000E+02 Total network loss = 5.660068288220E+02 + +******************************************************************************** +* * +* LINE MODEL FREQUENCY SCAN COMPARISON TABLE 30-Jul-93 * +* ZERO-SEQUENCE IMPEDANCE TEST * +* * +******************************************************************************************* + + LINE MODEL BEING TESTED EXACT-PI MODEL % ERROR + + FREQUENCY NODE MAG ANG REAL IMAG MAG ANG REAL IMAG PCTMAG PCTANG + + 6.000E+01 GENIA 3.258E+02 8.126E+01 4.950E+01 3.220E+02 3.240E+02 8.140E+01 4.845E+01 3.204E+02 .5405 -.173 + GENIB 3.258E+02 8.126E+01 4.950E+01 3.220E+02 3.271E+02 8.142E+01 4.878E+01 3.235E+02 -.427 -.204 + GENIC 3.258E+02 8.126E+01 4.950E+01 3.220E+02 3.240E+02 8.140E+01 4.845E+01 3.204E+02 .5405 -.173 + + 6.000E+02 GENIA 6.545E+02 5.425E+01 3.824E+02 5.312E+02 6.499E+02 5.467E+01 3.758E+02 5.303E+02 .7028 -.773 + GENIB 6.545E+02 5.425E+01 3.824E+02 5.312E+02 6.574E+02 5.464E+01 3.804E+02 5.361E+02 -.44 -.716 + GENIC 6.545E+02 5.425E+01 3.824E+02 5.312E+02 6.499E+02 5.467E+01 3.758E+02 5.303E+02 .7028 -.773 + +Blank card terminating all plot cards. |BLANK card ending batch-mode plot cards +Actual List Sizes for the preceding solution follow. 30-Jul-93 09.52.45 + Size 1-10: 10 12 15 3 -9999 0 -9999 -9999 0 0 + Size 11-20: -9999 30 -9999 -9999 -9999 0 0 0 23 470 + Size 21-29: 18 -9999 27 -9999 -9999 -9999 -9999 -9999 -9999 +Seconds for overlays 1-5 : 1.207 0.000 1.207 --- (CP: I/O; tot) +Seconds for overlays 6-11 : 1.430 0.000 1.430 +Seconds for overlays 12-15 : 0.000 0.000 0.000 +Seconds for time-step loop : 1.098 0.000 1.098 +Seconds after DELTAT-loop : 0.055 0.000 0.055 + --------------------------- + Totals : 3.789 0.000 3.789 + +EMTP begins. Send (SPY, file_name, DISK, HELP, GO, KEY, STOP, BOTH, DIR) : + --- 35 cards of disk file read into card cache cells 1 onward. + --- Pass 1. Card = 20. Ready to open $INCLUDE = dc51fs3.dat + --- Pass 1. Card = 122. Ready to open $INCLUDE = dc51fs3p.dat +Alternative Transients Program (ATP), Salford 80386 translation. All rights reserved by Can/Am user group of Portland, Oregon, USA. + Date (dd-mth-yy) and time of day (hh.mm.ss) = 30-Jul-93 09.56.45 Name of disk plot file, if any, is D:37300956.pl4 +Consult the 800-page ATP Rule Book of the Can/Am EMTP User Group in Portland, Oregon, USA. Program is no older than July, 1992. +Total size of LABCOM tables = 227363 INTEGER words. VARDIM List Sizes follow : 752 900 1500 150 7500 120 + 2100 5250 225 480 150 150 15000 60 10800 120 12 15 4800 1980 300 450 12000 9 1200 252 4 9600 +--------------------------------------------------+-------------------------------------------------------------------------------- +Descriptive interpretation of input data cards. | Input data card images are shown below, all 80 columns, character by character + 0 1 2 3 4 5 6 7 8 + 012345678901234567890123456789012345678901234567890123456789012345678901234567890 +--------------------------------------------------+-------------------------------------------------------------------------------- +Comment card. KOMPAR = 1. |C data:GO +Marker card preceding new EMTP data case. |BEGIN NEW DATA CASE +Comment card. KOMPAR = 1. |C 2nd of 3 data subcases. +Comment card. KOMPAR = 1. |C Illustration of LINE MODEL FREQUENCY SCAN (LMFS). For background of this +Comment card. KOMPAR = 1. |C feature that was first available in ATP at the end of March, 1992, see the + < < < Etc. (section removed) > > > +Blank card terminating frequency cards. |BLANK card ending frequency cards of "LINE CONSTANTS" data + 1) Freq [Hz] = 6.0000000E+01 Total network loss = 6.240924861294E+00 + 2) Freq [Hz] = 6.0000000E+02 Total network loss = 7.142960437129E+00 + +******************************************************************************** +* * +* LINE MODEL FREQUENCY SCAN COMPARISON TABLE 30-Jul-93 * +* POSITIVE-SEQUENCE IMPEDANCE TEST * +* * +******************************************************************************** + + LINE MODEL BEING TESTED EXACT-PI MODEL % ERROR + + FREQUENCY NODE MAG ANG REAL IMAG MAG ANG REAL IMAG PCTMAG PCTANG + + 6.000E+01 GENIA 8.329E+01 8.706E+01 4.276E+00 8.318E+01 8.381E+01 8.548E+01 6.605E+00 8.355E+01 -.624 1.845 + GENIB 8.329E+01 -3.294E+01 6.990E+01 -4.529E+01 8.257E+01 -3.296E+01 6.927E+01 -4.492E+01 .8778 -.061 + GENIC 8.329E+01 -1.529E+02 -7.417E+01 -3.789E+01 8.376E+01 -1.511E+02 -7.333E+01 -4.048E+01 -.561 1.219 + + 6.000E+02 GENIA 8.819E+01 -8.678E+01 4.952E+00 -8.805E+01 9.319E+01 -8.908E+01 1.488E+00 -9.317E+01 -5.36 -2.59 + GENIB 8.819E+01 1.532E+02 -7.873E+01 3.974E+01 8.182E+01 1.544E+02 -7.379E+01 3.536E+01 7.784 -.764 + GENIC 8.819E+01 3.322E+01 7.378E+01 4.832E+01 9.071E+01 3.412E+01 7.509E+01 5.089E+01 -2.77 -2.65 + + +Blank card terminating all plot cards. |BLANK card ending batch-mode plot cards +Actual List Sizes for the preceding solution follow. 30-Jul-93 09.52.47 + Size 1-10: 10 12 15 3 -9999 0 -9999 -9999 0 0 + Size 11-20: -9999 30 -9999 -9999 -9999 0 0 0 23 470 + Size 21-29: 18 -9999 27 -9999 -9999 -9999 -9999 -9999 -9999 +Seconds for overlays 1-5 : 1.262 0.000 1.262 --- (CP: I/O; tot) +Seconds for overlays 6-11 : 0.496 0.000 0.496 +Seconds for overlays 12-15 : 0.000 0.000 0.000 +Seconds for time-step loop : 0.000 0.000 0.000 +Seconds after DELTAT-loop : 0.055 0.000 0.055 + --------------------------- + Totals : 1.813 0.000 1.813 + + --- Pass 1. Card = 9. Ready to open $INCLUDE = dc51fs6.dat + --- Pass 1. Card = 193. Ready to open $INCLUDE = dc51fs6z.dat +Alternative Transients Program (ATP), Salford 80386 translation. All rights reserved by Can/Am user group of Portland, Oregon, USA. + Date (dd-mth-yy) and time of day (hh.mm.ss) = 30-Jul-93 09.57.47 Name of disk plot file, if any, is D:37300957.pl4 +Consult the 800-page ATP Rule Book of the Can/Am EMTP User Group in Portland, Oregon, USA. Program is no older than July, 1992. +Total size of LABCOM tables = 227363 INTEGER words. VARDIM List Sizes follow : 752 900 1500 150 7500 120 + 2100 5250 225 480 150 150 15000 60 10800 120 12 15 4800 1980 300 450 12000 9 1200 252 4 9600 +--------------------------------------------------+-------------------------------------------------------------------------------- +Descriptive interpretation of input data cards. | Input data card images are shown below, all 80 columns, character by character + 0 1 2 3 4 5 6 7 8 + 012345678901234567890123456789012345678901234567890123456789012345678901234567890 +--------------------------------------------------+-------------------------------------------------------------------------------- +Marker card preceding new EMTP data case. |BEGIN NEW DATA CASE +Comment card. KOMPAR = 1. |C 3rd of 3 data subcases illustrates LINE MODEL FREQUENCY SCAN (LMFS) for +Comment card. KOMPAR = 1. |C an untransposed double-circuit line generated by JMARTI SETUP. + < < < Etc. (section removed) > > > +Blank card ending node names for voltage output. |BLANK CARD ENDING NODE VOLTAGE OUTPUTS ==================================== + 2) Freq [Hz] = 7.5535525E+00 Total network loss = 1.460350203292E+01 + 3) Freq [Hz] = 9.5093592E+00 Total network loss = 1.740069938004E+01 + < < < Etc. (section removed) > > > + 40) Freq [Hz] = 4.7659694E+04 Total network loss = 2.219525952980E+03 + 41) Freq [Hz] = 6.0000000E+04 Total network loss = 2.202395130215E+03 +Compute overhead line constants. Limit = 100 | +Comment card. KOMPAR = 1. |C End of $INCLUDE. File name = 30 +Comment card. KOMPAR = 1. |C MR02D# ,MR04D# ,MR02E# ,MR04E# ,MR02F# ,MR04F# +Comment card. KOMPAR = 1. |C dc51fs6p.dat +Comment card. KOMPAR = 1. |C dc51fs6m.dat +Comment card. KOMPAR = 1. |C Raw LINE CONSTANTS data for the overhead transmission line being considered: +Line conductor card. 4.138E-01 4.970E-02 4 | 1.4138 .0497 4 1.603 -15. 52.0 A1-1 +Line conductor card. 4.138E-01 4.970E-02 4 | 1.4138 .0497 4 1.603 -16.06 53.06 A1-2 + < < < Etc. (section removed) > > > +Blank card terminating frequency cards. |BLANK card ending frequency cards of "LINE CONSTANTS" data + 1) Freq [Hz] = 6.0000000E+00 Total network loss = 1.163993843730E+01 + 2) Freq [Hz] = 7.5535525E+00 Total network loss = 1.392642800817E+01 + < < < Etc. (section removed) > > > + 40) Freq [Hz] = 4.7659694E+04 Total network loss = 2.223352249386E+03 + 41) Freq [Hz] = 6.0000000E+04 Total network loss = 2.203817311869E+03 + +******************************************************************************** +* * +* LINE MODEL FREQUENCY SCAN COMPARISON TABLE 30-Jul-93 * +* ZERO-SEQUENCE IMPEDANCE TEST * +* * +******************************************************************************** + + LINE MODEL BEING TESTED EXACT-PI MODEL % ERROR + + FREQUENCY NODE MAG ANG REAL IMAG MAG ANG REAL IMAG PCTMAG PCTANG + + 6.000E+00 GENIA 2.366E+01 8.006E+01 4.083E+00 2.331E+01 2.351E+01 8.070E+01 3.797E+00 2.320E+01 .6696 -.791 + GENIB 2.368E+01 7.984E+01 4.176E+00 2.331E+01 2.381E+01 8.038E+01 3.979E+00 2.347E+01 -.552 -.671 + GENIC 2.347E+01 7.996E+01 4.092E+00 2.311E+01 2.352E+01 8.055E+01 3.864E+00 2.320E+01 -.221 -.728 + GENID 2.347E+01 7.996E+01 4.092E+00 2.311E+01 2.352E+01 8.055E+01 3.864E+00 2.320E+01 -.221 -.728 + GENIE 2.368E+01 7.984E+01 4.176E+00 2.331E+01 2.381E+01 8.038E+01 3.979E+00 2.347E+01 -.552 -.671 + GENIF 2.366E+01 8.006E+01 4.083E+00 2.331E+01 2.351E+01 8.070E+01 3.797E+00 2.320E+01 .6696 -.791 + + 7.554E+00 GENIA 2.914E+01 8.041E+01 4.857E+00 2.873E+01 2.901E+01 8.092E+01 4.577E+00 2.865E+01 .4326 -.641 + GENIB 2.917E+01 8.030E+01 4.916E+00 2.876E+01 2.939E+01 8.073E+01 4.734E+00 2.900E+01 -.728 -.533 + GENIC 2.892E+01 8.038E+01 4.831E+00 2.851E+01 2.904E+01 8.085E+01 4.616E+00 2.867E+01 -.408 -.581 + GENID 2.892E+01 8.038E+01 4.831E+00 2.851E+01 2.904E+01 8.085E+01 4.616E+00 2.867E+01 -.408 -.581 + GENIE 2.917E+01 8.030E+01 4.916E+00 2.876E+01 2.939E+01 8.073E+01 4.734E+00 2.900E+01 -.728 -.533 + GENIF 2.914E+01 8.041E+01 4.857E+00 2.873E+01 2.901E+01 8.092E+01 4.577E+00 2.865E+01 .4326 -.641 + + < < < Etc. (section removed) > > > + + + 6.000E+04 GENIA 7.446E+02 -5.713E+00 7.409E+02 -7.413E+01 7.156E+02 -3.941E+00 7.139E+02 -4.919E+01 4.062 44.95 + GENIB 7.249E+02 -1.238E+00 7.247E+02 -1.566E+01 7.120E+02 -3.456E-01 7.120E+02 -4.295E+00 1.804 258.2 + GENIC 7.372E+02 -2.027E+00 7.367E+02 -2.607E+01 7.801E+02 -4.349E+00 7.779E+02 -5.916E+01 -5.51 -53.4 + GENID 7.372E+02 -2.027E+00 7.367E+02 -2.607E+01 7.801E+02 -4.349E+00 7.779E+02 -5.916E+01 -5.51 -53.4 + GENIE 7.249E+02 -1.238E+00 7.247E+02 -1.566E+01 7.120E+02 -3.456E-01 7.120E+02 -4.295E+00 1.804 258.2 + GENIF 7.446E+02 -5.713E+00 7.409E+02 -7.413E+01 7.156E+02 -3.941E+00 7.139E+02 -4.919E+01 4.062 44.95 + +Request for character (line printer) plotting. | PRINTER PLOT +>> Plot card. 5.000E-01 0.000E+00 5.000E+00 | 186 .5 0.0 5.0 GENIA MAG MARTI SECTION Z IN OHMS + +30-Jul-93 09.57.47 1 +Plot type 8 +Node names GENIA MAG +Time-axis legend : Frequency f in Hertz + + Z IN OHMS ( x 10**( 3) ) + 0.000 0.515 1.030 1.545 2.059 2.574 3.089 3.604 4.119 4.634 5.149 5.663 6.178 6.693 ++---------+---------+---------+---------+---------+---------+---------+---------+---------+---------+---------+---------+---------+ +| +| +| +| +| +| +| 0.5 +| +| +A +| +|A +|A +|A +|A +|A +| +| A +| A +| A +| A +| A +| +| A +| 2.0 A +| A +| A +| A +| +| A +| 2.5 A +| A +| A +| A +| +| A +| 3.0 A +| A +| A +| A +| +| A +| 3.5 A +| A +| A +| A +| +| A +| 4.0 A +| A +| A +| A +| +| A +| 4.5 A +| A +| A +| A +End of graph. + + < < < Etc. (section removed) > > > + +Blank card terminating all plot cards. |BLANK card ending batch-mode (CalComp) plot cards +Actual List Sizes for the preceding solution follow. 30-Jul-93 09.52.59 + Size 1-10: 19 24 39 6 -9999 0 -9999 -9999 0 0 + Size 11-20: -9999 60 82 -9999 -9999 0 0 0 23 1073 + Size 21-29: 72 -9999 90 -9999 -9999 -9999 -9999 -9999 -9999 +Seconds for overlays 1-5 : 1.703 0.000 1.703 --- (CP: I/O; tot) +Seconds for overlays 6-11 : 8.461 0.000 8.461 +Seconds for overlays 12-15 : 0.000 0.000 0.000 +Seconds for time-step loop : 1.047 0.000 1.047 +Seconds after DELTAT-loop : 0.879 0.000 0.879 + --------------------------- + Totals : 12.090 0.000 12.090 + +EMTP begins. Send (SPY, file_name, DISK, HELP, GO, KEY, STOP, BOTH, DIR) : + --- 44 cards of disk file read into card cache cells 1 onward. + --- Pass 1. Card = 10. Ready to open $INCLUDE = dc51fs6.dat + --- Pass 1. Card = 194. Ready to open $INCLUDE = dc51fs6p.dat +Alternative Transients Program (ATP), Salford 80386 translation. All rights reserved by Can/Am user group of Portland, Oregon, USA. + Date (dd-mth-yy) and time of day (hh.mm.ss) = 30-Jul-93 09.58.00 Name of disk plot file, if any, is D:37300958.pl4 +Consult the 800-page ATP Rule Book of the Can/Am EMTP User Group in Portland, Oregon, USA. Program is no older than July, 1992. +Total size of LABCOM tables = 227363 INTEGER words. VARDIM List Sizes follow : 752 900 1500 150 7500 120 + 2100 5250 225 480 150 150 15000 60 10800 120 12 15 4800 1980 300 450 12000 9 1200 252 4 9600 +--------------------------------------------------+-------------------------------------------------------------------------------- +Descriptive interpretation of input data cards. | Input data card images are shown below, all 80 columns, character by character + 0 1 2 3 4 5 6 7 8 + 012345678901234567890123456789012345678901234567890123456789012345678901234567890 +--------------------------------------------------+-------------------------------------------------------------------------------- +Comment card. KOMPAR = 1. |C data:GO +Marker card preceding new EMTP data case. |BEGIN NEW DATA CASE +Comment card. KOMPAR = 1. |C 3rd of 3 data subcases illustrates LINE MODEL FREQUENCY SCAN (LMFS) for +Comment card. KOMPAR = 1. |C an untransposed double-circuit line generated by JMARTI SETUP. + < < < Etc. (section removed) > > > +Blank card ending node names for voltage output. |BLANK CARD ENDING NODE VOLTAGE OUTPUTS ==================================== + 2) Freq [Hz] = 7.5535525E+00 Total network loss = 2.186843544415E+00 + 3) Freq [Hz] = 9.5093592E+00 Total network loss = 2.201132634968E+00 + < < < Etc. (section removed) > > > + 40) Freq [Hz] = 4.7659694E+04 Total network loss = 5.301174275213E+01 + 41) Freq [Hz] = 6.0000000E+04 Total network loss = 7.652463362163E+01 +Compute overhead line constants. Limit = 100 | + < < < Etc. (section removed) > > > +Line conductor card. 4.138E-01 4.970E-02 4 | 1.4138 .0497 4 1.603 -15. 52.0 A1-1 +Line conductor card. 4.138E-01 4.970E-02 4 | 1.4138 .0497 4 1.603 -16.06 53.06 A1-2 + < < < Etc. (section removed) > > > +Blank card terminating frequency cards. |BLANK card ending frequency cards of "LINE CONSTANTS" data + 1) Freq [Hz] = 6.0000000E+00 Total network loss = 2.644053558159E+00 + 2) Freq [Hz] = 7.5535525E+00 Total network loss = 2.646292442603E+00 + < < < Etc. (section removed) > > > + 40) Freq [Hz] = 4.7659694E+04 Total network loss = 6.165455521027E+01 + 41) Freq [Hz] = 6.0000000E+04 Total network loss = 9.153350121473E+01 + +******************************************************************************** +* * +* LINE MODEL FREQUENCY SCAN COMPARISON TABLE 30-Jul-93 * +* POSITIVE-SEQUENCE IMPEDANCE TEST * +* * +******************************************************************************** + + LINE MODEL BEING TESTED EXACT-PI MODEL % ERROR + + + FREQUENCY NODE MAG ANG REAL IMAG MAG ANG REAL IMAG PCTMAG PCTANG + + 6.000E+00 GENIA 2.626E+00 7.474E+01 6.912E-01 2.534E+00 2.604E+00 6.958E+01 9.085E-01 2.440E+00 .8639 7.416 + GENIB 2.711E+00 -4.640E+01 1.869E+00 -1.963E+00 2.813E+00 -4.956E+01 1.825E+00 -2.141E+00 -3.65 -6.39 + GENIC 2.663E+00 -1.655E+02 -2.578E+00 -6.683E-01 2.664E+00 -1.671E+02 -2.596E+00 -5.939E-01 -.008 -.987 + GENID 2.608E+00 7.375E+01 7.299E-01 2.503E+00 2.625E+00 6.918E+01 9.329E-01 2.453E+00 -.653 6.599 + GENIE 2.746E+00 -4.615E+01 1.902E+00 -1.980E+00 2.808E+00 -4.910E+01 1.839E+00 -2.123E+00 -2.21 -6. + GENIF 2.626E+00 -1.651E+02 -2.538E+00 -6.750E-01 2.644E+00 -1.677E+02 -2.583E+00 -5.654E-01 -.693 -1.52 + + 7.554E+00 GENIA 3.268E+00 7.756E+01 7.038E-01 3.191E+00 3.218E+00 7.334E+01 9.228E-01 3.083E+00 1.542 5.761 + GENIB 3.368E+00 -4.312E+01 2.458E+00 -2.302E+00 3.467E+00 -4.578E+01 2.418E+00 -2.485E+00 -2.87 -5.8 + GENIC 3.291E+00 -1.625E+02 -3.139E+00 -9.906E-01 3.285E+00 -1.635E+02 -3.150E+00 -9.335E-01 .1779 -.618 + GENID 3.246E+00 7.675E+01 7.439E-01 3.160E+00 3.249E+00 7.288E+01 9.567E-01 3.105E+00 -.094 5.321 + GENIE 3.405E+00 -4.296E+01 2.492E+00 -2.321E+00 3.463E+00 -4.529E+01 2.437E+00 -2.461E+00 -1.69 -5.13 + GENIF 3.255E+00 -1.622E+02 -3.098E+00 -9.965E-01 3.251E+00 -1.641E+02 -3.126E+00 -8.919E-01 .1212 -1.16 + + < < < Etc. (section removed) > > > + + 6.000E+04 GENIA 1.758E+02 5.490E+01 1.011E+02 1.438E+02 2.043E+02 5.199E+01 1.258E+02 1.610E+02 -14. 5.593 + GENIB 2.032E+02 -1.852E+01 1.927E+02 -6.454E+01 2.288E+02 -1.702E+01 2.188E+02 -6.699E+01 -11.2 8.777 + GENIC 8.011E+01 -1.524E+02 -7.101E+01 -3.709E+01 7.719E+01 -1.493E+02 -6.634E+01 -3.947E+01 3.787 2.124 + GENID 1.186E+02 9.365E+01 -7.560E+00 1.184E+02 1.343E+02 8.904E+01 2.259E+00 1.343E+02 -11.7 5.186 + GENIE 1.089E+02 -6.696E+01 4.262E+01 -1.002E+02 1.143E+02 -6.770E+01 4.338E+01 -1.058E+02 -4.72 -1.08 + GENIF 1.970E+02 -1.591E+02 -1.841E+02 -7.034E+01 2.168E+02 -1.600E+02 -2.036E+02 -7.428E+01 -9.1 -.548 + +Request for character (line printer) plotting. | PRINTER PLOT +>> Plot card. 5.000E-01 0.000E+00 5.000E+00 | 186 .5 0.0 5.0 GENIA MAG MARTI SECTION Z IN OHMS + +30-Jul-93 09.58.00 1 +Plot type 8 +Node names GENIA MAG +Time-axis legend : Frequency f in Hertz + + Z IN OHMS ( x 10**( 3) ) + 0.000 0.123 0.246 0.370 0.493 0.616 0.739 0.862 0.985 1.109 1.232 1.355 1.478 1.601 ++---------+---------+---------+---------+---------+---------+---------+---------+---------+---------+---------+---------+---------+ + + < < < Etc. (section removed) > > > + +Blank card terminating all plot cards. |BLANK card ending batch-mode (CalComp) plot cards +Actual List Sizes for the preceding solution follow. 30-Jul-93 09.53.11 + Size 1-10: 19 24 39 6 -9999 0 -9999 -9999 0 0 + Size 11-20: -9999 60 82 -9999 -9999 0 0 0 23 1073 + Size 21-29: 72 -9999 90 -9999 -9999 -9999 -9999 -9999 -9999 +Seconds for overlays 1-5 : 1.539 0.000 1.539 --- (CP: I/O; tot) +Seconds for overlays 6-11 : 8.406 0.000 8.406 +Seconds for overlays 12-15 : 0.000 0.000 0.000 +Seconds for time-step loop : 0.934 0.000 0.934 +Seconds after DELTAT-loop : 0.879 0.000 0.879 + --------------------------- + Totals : 11.758 0.000 11.758 + +EMTP begins. Send (SPY, file_name, DISK, HELP, GO, KEY, STOP, BOTH, DIR) : + --- 44 cards of disk file read into card cache cells 1 onward. + --- Pass 1. Card = 10. Ready to open $INCLUDE = dc51fs6.dat + --- Pass 1. Card = 194. Ready to open $INCLUDE = dc51fs6m.dat +Alternative Transients Program (ATP), Salford 80386 translation. All rights reserved by Can/Am user group of Portland, Oregon, USA. + Date (dd-mth-yy) and time of day (hh.mm.ss) = 30-Jul-93 09.59.12 Name of disk plot file, if any, is D:37300959.pl4 +Consult the 800-page ATP Rule Book of the Can/Am EMTP User Group in Portland, Oregon, USA. Program is no older than July, 1992. +Total size of LABCOM tables = 227363 INTEGER words. VARDIM List Sizes follow : 752 900 1500 150 7500 120 + 2100 5250 225 480 150 150 15000 60 10800 120 12 15 4800 1980 300 450 12000 9 1200 252 4 9600 +--------------------------------------------------+-------------------------------------------------------------------------------- +Descriptive interpretation of input data cards. | Input data card images are shown below, all 80 columns, character by character + 0 1 2 3 4 5 6 7 8 + 012345678901234567890123456789012345678901234567890123456789012345678901234567890 +--------------------------------------------------+-------------------------------------------------------------------------------- +Comment card. KOMPAR = 1. |C data:GO +Marker card preceding new EMTP data case. |BEGIN NEW DATA CASE +Comment card. KOMPAR = 1. |C 3rd of 3 data subcases illustrates LINE MODEL FREQUENCY SCAN (LMFS) for +Comment card. KOMPAR = 1. |C an untransposed double-circuit line generated by JMARTI SETUP. + < < < Etc. (section removed) > > > +Blank card ending node names for voltage output. |BLANK CARD ENDING NODE VOLTAGE OUTPUTS ==================================== + 2) Freq [Hz] = 7.5535525E+00 Total network loss = 4.247788777322E+00 + 3) Freq [Hz] = 9.5093592E+00 Total network loss = 4.950100153259E+00 + < < < Etc. (section removed) > > > + 40) Freq [Hz] = 4.7659694E+04 Total network loss = 6.576631373437E+02 + 41) Freq [Hz] = 6.0000000E+04 Total network loss = 7.406315999451E+02 +Compute overhead line constants. Limit = 100 | + < < < Etc. (section removed) > > > +Blank card terminating frequency cards. |BLANK card ending frequency cards of "LINE CONSTANTS" data + 1) Freq [Hz] = 6.0000000E+00 Total network loss = 3.573399585181E+00 + 2) Freq [Hz] = 7.5535525E+00 Total network loss = 4.146632333116E+00 + < < < Etc. (section removed) > > > + 40) Freq [Hz] = 4.7659694E+04 Total network loss = 6.610984397030E+02 + 41) Freq [Hz] = 6.0000000E+04 Total network loss = 7.522122408557E+02 + +******************************************************************************** +* * +* LINE MODEL FREQUENCY SCAN COMPARISON TABLE 30-Jul-93 * +* MUTUAL IMPEDANCE TEST * +* * +******************************************************************************** + + LINE MODEL BEING TESTED EXACT-PI MODEL % ERROR + + FREQUENCY NODE MAG ANG REAL IMAG MAG ANG REAL IMAG PCTMAG PCTANG + + 6.000E+00 GENIA 1.335E+01 7.964E+01 2.401E+00 1.313E+01 1.327E+01 7.985E+01 2.339E+00 1.306E+01 .6346 -.259 + GENIB 1.364E+01 7.935E+01 2.521E+00 1.341E+01 1.370E+01 7.978E+01 2.431E+00 1.348E+01 -.399 -.531 + GENIC 1.326E+01 7.939E+01 2.442E+00 1.304E+01 1.330E+01 7.971E+01 2.377E+00 1.309E+01 -.261 -.395 + GENID 1.021E+01 8.070E+01 1.650E+00 1.007E+01 1.023E+01 8.164E+01 1.487E+00 1.012E+01 -.187 -1.15 + GENIE 1.004E+01 8.050E+01 1.656E+00 9.898E+00 1.011E+01 8.120E+01 1.547E+00 9.993E+00 -.765 -.855 + GENIF 1.031E+01 8.062E+01 1.681E+00 1.017E+01 1.024E+01 8.181E+01 1.458E+00 1.014E+01 .6897 -1.46 + + 7.554E+00 GENIA 1.647E+01 8.025E+01 2.790E+00 1.623E+01 1.639E+01 8.042E+01 2.729E+00 1.617E+01 .4408 -.215 + GENIB 1.684E+01 8.011E+01 2.892E+00 1.659E+01 1.693E+01 8.045E+01 2.810E+00 1.670E+01 -.545 -.42 + GENIC 1.637E+01 8.010E+01 2.813E+00 1.612E+01 1.644E+01 8.035E+01 2.755E+00 1.621E+01 -.454 -.314 + GENID 1.256E+01 8.075E+01 2.018E+00 1.239E+01 1.260E+01 8.151E+01 1.861E+00 1.246E+01 -.356 -.924 + GENIE 1.234E+01 8.056E+01 2.023E+00 1.217E+01 1.246E+01 8.111E+01 1.924E+00 1.231E+01 -.979 -.685 + GENIF 1.267E+01 8.061E+01 2.067E+00 1.250E+01 1.262E+01 8.158E+01 1.848E+00 1.249E+01 .4114 -1.19 + + < < < Etc. (section removed) > > > + + 6.000E+04 GENIA 5.510E+02 1.845E+01 5.227E+02 1.744E+02 5.618E+02 2.101E+01 5.244E+02 2.015E+02 -1.91 -12.2 + GENIB 5.619E+02 2.300E+01 5.173E+02 2.195E+02 5.683E+02 2.425E+01 5.182E+02 2.334E+02 -1.12 -5.17 + GENIC 4.576E+02 1.536E+01 4.413E+02 1.212E+02 4.744E+02 1.321E+01 4.618E+02 1.084E+02 -3.53 16.24 + GENID 3.301E+02 -2.650E+01 2.954E+02 -1.473E+02 3.577E+02 -2.794E+01 3.161E+02 -1.676E+02 -7.72 -5.15 + GENIE 3.136E+02 -4.859E+01 2.075E+02 -2.352E+02 3.067E+02 -5.080E+01 1.939E+02 -2.377E+02 2.241 -4.36 + GENIF 3.308E+02 -4.872E+01 2.182E+02 -2.486E+02 3.142E+02 -5.291E+01 1.895E+02 -2.506E+02 5.275 -7.93 + + +Request for character (line printer) plotting. | PRINTER PLOT +>> Plot card. 5.000E-01 0.000E+00 5.000E+00 | 186 .5 0.0 5.0 GENIA MAG MARTI SECTION Z IN OHMS + +30-Jul-93 09.59.12 1 +Plot type 8 +Node names GENIA MAG +Time-axis legend : Frequency f in Hertz + + Z IN OHMS ( x 10**( 3) ) + 0.000 0.254 0.507 0.761 1.015 1.268 1.522 1.776 2.029 2.283 2.537 2.790 3.044 3.298 ++---------+---------+---------+---------+---------+---------+---------+---------+---------+---------+---------+---------+---------+ + < < < Etc. (section removed) > > > +Blank card terminating all plot cards. |BLANK card ending batch-mode (CalComp) plot cards +Actual List Sizes for the preceding solution follow. 30-Jul-93 09.53.22 + Size 1-10: 19 24 39 3 -9999 0 -9999 -9999 0 0 + Size 11-20: -9999 60 82 -9999 -9999 0 0 0 23 1073 + Size 21-29: 72 -9999 90 -9999 -9999 -9999 -9999 -9999 -9999 +Seconds for overlays 1-5 : 1.703 0.000 1.703 --- (CP: I/O; tot) +Seconds for overlays 6-11 : 8.133 0.000 8.133 +Seconds for overlays 12-15 : 0.000 0.000 0.000 +Seconds for time-step loop : 0.055 0.000 0.055 +Seconds after DELTAT-loop : 0.879 0.000 0.879 + --------------------------- + Totals : 10.770 0.000 10.770 + -- cgit v1.2.3