From b18347ffc9db9641e215995edea1c04c363b2bdf Mon Sep 17 00:00:00 2001 From: Angelo Rossi Date: Wed, 21 Jun 2023 12:04:16 +0000 Subject: Initial commit. --- benchmarks/dc28.dat | 511 ++++++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 511 insertions(+) create mode 100644 benchmarks/dc28.dat (limited to 'benchmarks/dc28.dat') diff --git a/benchmarks/dc28.dat b/benchmarks/dc28.dat new file mode 100644 index 0000000..c304d5d --- /dev/null +++ b/benchmarks/dc28.dat @@ -0,0 +1,511 @@ +BEGIN NEW DATA CASE +C BENCHMARK DC-28 +C "CABLE CONSTANTS" illustration begins with a finite, overhead pipe that +C encloses a 3-phase cable system. Each phase consists of a core only. +C For nodes of punched cards, the cable stretches from end "1" to end "2". +C The cable length (872 meters) is used only for this special output. +C 1st of 4 subcases. +CABLE CONSTANTS +$ERASE { Empty punch buffer as precautionary measure (maybe preceding case) +BRANCH CORA1 CORA2 CORB1 CORB2 CORC1 CORC2 PIPE1 PIPE2 + 3 1 3 1 1 1 1 + 0.381 0.401 0.421 2.E-7 300. 1. 3. + 0.19393 0. 0.19393 120. 0.19393 240. + 1 1 1 + 25.4E-3 + 6.8912E-8 1. + 25.4E-3 + 6.8912E-8 1. + 25.4E-3 + 6.8912E-8 1. + 1.0 0.0 + 20.0 10. 872. { Cable length = 872 meters +C Impedance matrix [ Z ] in [ohm/m] follows : +C 8.5303094E-05 4.9395039E-05 4.9395039E-05 2.9513780E-05 +C 1.7535768E-04 1.3713248E-04 1.3713248E-04 1.1639059E-04 +C Admittance matrix [ Y ] in [mho/m] follows : +C 0.0000000E+00 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 1.4843948E-09 -1.4823084E-10 -1.4823084E-10 -1.1879330E-09 +C Voltage transformation matrices follow. These are complex, with the mag +C 0.0034957 0.0034958 0.0034959 1.0099676 +C -162.8209534 -162.8215332 -162.8218384 0.1735267 +C Transformation [A], from modal to phase variables: +C 0.9937597 0.9999998 0.4999998 1.0000000 +C -0.1112594 0.0000057 -179.9999847 0.0000000 +C Characteristic impedance matrix [Zc] in phase variables, in [ohm]: +C 447.5839844 280.9452515 280.9451599 230.7716522 +C -115.0411224 -49.0479126 -49.0479584 -28.8765430 +C Modal Propagation Modal impedance Modal +C Mode attenuation velocity real imaginary susceptance +C [ db/km ] [ m/sec ] [ ohms / meter ] [mho/meter] +C 1 5.49837E-04 1.22476E+08 2.925856E-05 1.167339E-04 2.220200E-09 +C 2 1.29433E-03 1.66288E+08 3.202234E-05 3.470583E-05 3.493539E-09 +C 3 9.35837E-04 2.30950E+08 2.393871E-05 2.548347E-05 2.448938E-09 +C 4 9.35837E-04 2.30950E+08 1.795402E-05 1.911261E-05 3.265251E-09 +$PUNCH, dc28a.pch ! { Exclamation holds lower case +BLANK card ending frequency cards +C $VINTAGE, 1 +C -1CORA1 CORA2 2.92540E-05 2.29300E+02 1.22476E+08-8.72000E+02 1 4 +C -2CORB1 CORB2 3.22334E-05 9.93885E+01 1.66288E+08-8.72000E+02 1 4 +C -3CORC1 CORC2 2.39387E-05 1.02010E+02 2.30950E+08-8.72000E+02 1 4 +C -4PIPE1 PIPE2 1.79540E-05 7.65071E+01 2.30950E+08-8.72000E+02 1 4 +C $VINTAGE, 0 +C -0.00334000 -0.00333993 -0.00334000 1.00996333 +C -0.00103249 -0.00103249 -0.00103246 0.00307810 +C 0.33665633 0.33665612 0.33665576 -1.00366375 +C -0.00000644 -0.00000645 -0.00000664 0.00196862 +C -0.33333370 -0.33333334 0.66666698 0.00000001 +C -0.00000003 -0.00000004 -0.00000004 0.00000023 +C -0.50000012 0.50000012 -0.00000004 0.00000016 +C -0.00000005 -0.00000005 0.00000001 0.00000022 +C 2nd fourth of test involves a submarine cable donated by BC Hydro. It is +C modeled as a single-phase, 3-conductor cable. There is a core, a sheath, +C and armor, with the armor grounded. + 2 -1 1 1 1 1 2 + 3 + 0.01 0.02525 0.0518 0.055553 0.0675 0.0735 + 1.78E-8 1.0 1.0 3.5 2.8E-7 1.0 1.0 3.5 + 7.54E-8 1.0 + 0.2 0.0 + 0.21 10.0000 5 1 +C From final calculation of logarithmic looping, 1.00000000E+06 Hertz. : +C Impedance matrix [ Z ] in [ohm/m] follows : +C 9.1996193E-03 4.3044090E-03 +C 1.1569544E+00 2.4907887E-01 +C Admittance matrix [ Y ] in [mho/m] follows : +C 0.0000000E+00 0.0000000E+00 +C 1.7025936E-03 -1.7025938E-03 +C Voltage transformation matrices follow. These are complex, with the magnitud +C Transformation [AI], from phase to modal variables: +C 0.0000011 1.0000008 +C -135.8211517 0.0000440 +C Transformation [A], from modal to phase variables: +C 0.9999925 1.0000000 +C -0.0004397 0.0000000 +C Characteristic impedance matrix [Zc] in phase variables, in [ohm]: +C 29.3894901 6.2976413 +C -0.1167270 -0.0544422 +C ..... Modal Characteristic impedance Characteristic admittance +C ..... susceptance real imaginary real imaginary +C ..... [mho/meter] SQRT ( z / y ) in [ohm] SQRT ( y / z ) in [mho] +C ..... 6.280722E-03 6.297670E+00 -5.441193E-02 1.587770E-01 1.371835E-03 +C ..... 1.702591E-03 2.309191E+01 -6.221918E-02 4.330489E-02 1.166813E-04 +BLANK card ending frequency cards +C 3rd of 4 subcases generates PI-circuit modeling of a crossbonded cable +C having one major section. Armor is solidly grounded, and sheaths are +C cross-bonded. TEPCO OF275KV SC CABLE. MAY 17, 1985 +$ERASE { Empty punch buffer as precautionary measure (maybe preceding case) +C BRANCH CORA1 CORA2 CORB1 CORB2 CORC1 CORC2 SHEA1 SHEA2 SHEB1 SHEB2 SHEC1 SHEC2 +C Ashok Parsotam of Vector Limited in Auckland, New Zealand, inspired a rule +C change for BRANCH data that eliminates the former need for name packing. +C 26 December 2008, WSM replaces preceding packed card by the new equivalent +C form which ignores imbedded blank name pairs. This improves readability & +C makes easier any later addition or subtraction of conductors. In order to +C handle the rare case where both ends of a conductor are grounded, replace +C the former 12 blank bytes by "TERRA TERRA " (upon recognition, this will +C be replaced by the two desired blank names). Another special case is that +C where a name pair has not been defined. Most commonly this will be due to +C a user who supplies no BRANCH declaration at all. But in the more general +C case, the user may simply not have supplied enough non-blank name pairs to +C cover all phases. In either case, any unnamed phase will be labeled using +C the 2A6 default name pair "NoNameNoName". +BRANCH CORA1 CORA2 CORB1 CORB2 CORC1 CORC2 { All cores are numbered first, note +BRANCH SHEA1 SHEA2 SHEB1 SHEB2 SHEC1 SHEC2 { Next in the numbering: all sheaths +PUNCH { Request for punched output of PI-circuits that are to be determined + 2 -1 3 0 1 1 1 2 + -1 1 0 1.E3 1.E-1A + 3 3 3 + 0.0132 0.0249 0.0542 0.057 0.063 0.066 0.072 + 1.89E-8 1.0 1.0 2.30 3.00E-8 1.0 1.0 3.50 + 3.E-8 1.0 1.0 3.50 + 0.0132 0.0249 0.0542 0.057 0.063 0.066 0.072 + 1.89E-8 1.0 1.0 2.30 3.00E-8 1.0 1.0 3.50 + 3.E-8 1.0 1.0 3.50 + 0.0132 0.0249 0.0542 0.057 0.063 0.066 0.072 + 1.89E-8 1.0 1.0 2.30 3.00E-8 1.0 1.0 3.50 + 3.E-8 1.0 1.0 3.50 + 2. 0. 1.8095 0.11 2. .22 + 1.E2 1.E3 +$PUNCH { Actual punching of card images that by now must be in punch buffer +C $VINTAGE, 1 +C AIN 4 1.0000000E-01 +C 1AIN 1A 11 1 3.2000030E-02 6.5728021E-02 5.4835246E-02 +C 2AIN 2A 11 2 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 3.1999972E-02 6.5727922E-02 5.4835246E-02 +C 3AIN 3A 11 3 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 3.1999991E-02 6.5727972E-02 5.4835246E-02 +C 4AIN 4A 11 4 1.1000064E-02 9.2998579E-03 -5.4835252E-02 +C 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 2.0414416E-02 8.7684233E-03 7.0333978E-01 +C 5AIN 4A 11 5 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 1.1000006E-02 9.2997591E-03 -5.4835252E-02 +C 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 2.0414358E-02 8.7683245E-03 7.0333978E-01 +C 6AIN 4A 11 6 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 1.1000026E-02 9.2998085E-03 -5.4835252E-02 +C 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 0.0000000E+00 0.0000000E+00 0.0000000E+00 +C 2.0414377E-02 8.7683739E-03 7.0333978E-01 +C 1A 11 1A 12 1AIN 1A 11 1 +C 2A 11 2A 12 2 +C 3A 11 3A 12 3 +C 4A 11 6A 12 4 +C 5A 11 4A 12 5 +C 6A 11 5A 12 6 +C 1A 12 1AOUT 1AIN 1A 11 1 +C 2A 12 2AOUT 2 +C 3A 12 3AOUT 3 +C 4A 12 6AOUT 4 +C 5A 12 4AOUT 4 +C 6A 12 5AOUT 4 +C AOUT 4 AIN 4 +C $VINTAGE, 0 +BLANK CARD ENDING FREQUENCY CARDS +C 4th of 4 subcases. A three phase cable enclosed in a pipe with infinite +C thickness. This case was brought to us by Prof. Aki Ametani in September +C of 1993. Warning! Prof. Ametani spent 3 weeks at BPA during the summer +C of 1994, and warned that this solution is wrong. The same data can be +C found in 4th of 4 pipe-type illustrations of CABLE PARAMETERS that have +C been appended to DC-27. Note the number of phases below is 8 whereas the +C correct number is 9 (each of 3 phases has 3 conductors; the pipe does not +C contribute because it is infinitely thick). THL, 17 Aug 1994. +C Results of this case changed on March 2, 2001 after implementing the +C correction that Prof. Ametani made on February 17, 2001. +C This correction only affects cables having 3 layers of conductors: core, +C sheath and armor. +BRANCH CORA1 CORA2 CORB1 CORB2 CORC1 CORC2 SHEA1 SHEA2 SHEB1 SHEB2 SHEC1 SHEC2 +BRANCH ARMA1 ARMA2 ARMB1 ARMB2 ARMC1 ARMC2 + 3 -1 3 0 1 1 1 0 1 + 1.850 1.860 1.870 33.0 1.0 1. 1. +1.17183738-29.9354891.18391480-38.1912031.32171262-33.629952 + 3 3 3 + 11.0E-3 30.60E-3 63.80E-3 65.80E-3 71.00E-3 71.80E-3 76.80E-3 + 1.8365E-8 1.0 1.0 2.3 1.8365E-8 1.0 1.0 1. + 10.00E-8 1.0 1.0 8.0 + 11.0E-3 30.60E-3 63.80E-3 65.80E-3 71.00E-3 71.80E-3 76.80E-3 + 1.8365E-8 1.0 1.0 2.3 1.8365E-8 1.0 1.0 1. + 10.00E-8 1.0 1.0 8.0 + 11.0E-3 30.60E-3 63.80E-3 65.80E-3 71.00E-3 71.80E-3 76.80E-3 + 1.8365E-8 1.0 1.0 2.3 1.8365E-8 1.0 1.0 1. + 10.00E-8 1.0 1.0 8.0 + 33.0 100.0E03 +$PUNCH +BLANK card ending frequency cards +BLANK card ending "CABLE CONSTANTS" data subcases +BEGIN NEW DATA CASE +C August, 1994. Prof. Akihiro Ametani has left after 3 weeks of work +C at BPA to install his new CABLE PARAMETERS program. There are 18 +C standard test cases for this, and these will be split between the +C ends of DC-27 and DC-28. See DC-27 for the 6 files CASE1*.DAT +C for overhead lines (11A, 11G0, 11G1, 11G3, 11Y2, and 11A') and the +C 4 files CASE3#.DAT for pipe-type cables (3G0, 3G1, 3G4, and 3NP0). +C Those totaled 10 of 18. Here we add the remaining 8, CASE2*.DAT : +C 1st of 8 examples of cables without pipe: CASE21G0.DAT +CABLE CONSTANTS +CABLE PARAMETERS +C KOLW27 KOLS27 +MATRIX PRECISION 0 0 { Optimally encode old F-field values +C 4 December 2003, optional local KOLWID and KOLSEP of optimal encoding +C are read from columns 25-40. Variables are local to overlay 27, and are +C carried in LABL27. The default values (for default use, see DC-28) are +C KOLW27 = 10 and KOLS27 = 2 (column width of 10 including 2 blanks to +C separate matrix columns). Normally, if this is what the user wants, he +C would have no MATRIX PRECISION request. But we can produce the same +C effect by specifying illegal values (0 and 0). Both integers must be +C positive, so the zero values shown above will be rejected and data card +C interpretation should confirm default values KOLW27 = 10 & KOLSEP = 2. +C MATRIX OUTPUTS 1 + 2 -1 3 0 1 0 0 0 0 0 0 0 + 2 2 2 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 2.500 0.0 2.730 0.0 2.960 0.0 + 100. 50.E03 +C Total impedance [Zc] +C 4.63767E-02 4.55563E-02 4.55049E-02 4.57808E-02 4.55563E-02 4.55049E-02 +C 4.74692E-01 3.12743E-01 2.69461E-01 4.07294E-01 3.12743E-01 2.69461E-01 +C MODE ATTENUATION VELOCITY IMPEDANCE (OHM/M) ADMITTANCE (S/M) +C NO. (DB/KM) (M/MIC.S) REAL IMAG. REAL IMAG. +C 1 1.27756E+01 14.46 4.84121E-02 3.55829E-01 0.00000E+00 1.31982E-03 +C 2 6.55379E-02 39.08 1.29966E-04 6.92398E-02 0.00000E+00 9.33476E-04 +C 3 8.29132E-02 51.43 1.61257E-04 5.15928E-02 0.00000E+00 7.23141E-04 +C 4 7.73951E-02 153.52 5.86972E-04 6.73995E-02 0.00000E+00 6.21266E-05 +C 5 7.73951E-02 153.52 5.86971E-04 6.73994E-02 0.00000E+00 6.21267E-05 +C 6 7.73951E-02 153.52 5.86971E-04 6.73994E-02 0.00000E+00 6.21267E-05 +BLANK card ending frequency cards +BLANK card ending "CABLE CONSTANTS" data subcases +BEGIN NEW DATA CASE +C 2nd of 8 examples of cables without pipe: CASE21G3.DAT +CABLE CONSTANTS +CABLE PARAMETERS +C 2 -1 3 0 0 0 0 0 3 0 0 0 + 2 -1 3 0 1 0 0 0 3 0 0 0 + 2 2 2 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 2.500 0.0 2.730 0.0 2.960 0.0 + 100. 50.E03 +C Total admittance [Yc] +C 0.00000E+00 0.00000E+00 0.00000E+00 +C 6.21268E-05 0.00000E+00 0.00000E+00 +C .... ADMITTANCE (S/M) CHARACT. IMP. (OHM) CHARACT. ADMIT. (S) +C .... REAL IMAG. REAL IMAG. REAL IMAG. +C .... 0.00000E+00 6.21268E-05 32.938 -0.143 3.03598E-02 1.32197E-04 +C .... 0.00000E+00 6.21268E-05 32.938 -0.143 3.03598E-02 1.32197E-04 +C .... 0.00000E+00 6.21268E-05 32.938 -0.143 3.03598E-02 1.32197E-04 +BLANK card ending frequency cards +BLANK card ending "CABLE CONSTANTS" data subcases +BEGIN NEW DATA CASE +C 3rd of 8 examples of cables without pipe: CASE21S1.DAT +CABLE CONSTANTS +CABLE PARAMETERS +C 2 -1 3 0 0 0 0 -99 0 0 0 0 + 2 -1 3 0 1 0 0 -99 0 0 0 0 + 2 2 2 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 2.500 0.0 2.730 0.0 2.960 0.0 + 100. 50.E03 +C Characteristic impedance matrix [Zc] in phase variables, in [ohm]: +C 58.63021 10.39525 10.39524 25.69268 10.39520 10.39519 +C -1.20548 -1.04447 -1.04448 -1.06129 -1.04478 -1.04480 +C +C .... ADMITTANCE (S/M) CHARACT. IMP. (OHM) CHARACT. ADMIT. (S) +C .... REAL IMAG. REAL IMAG. REAL IMAG. +C .... 0.00000E+00 1.40154E-03 15.494 -1.050 6.42445E-02 4.35431E-03 +C .... 0.00000E+00 7.00772E-04 10.198 -0.010 9.80544E-02 9.95546E-05 +C .... 0.00000E+00 9.34367E-04 7.649 -0.008 1.30740E-01 1.32736E-04 +C .... 0.00000E+00 6.21267E-05 32.938 -0.143 3.03598E-02 1.32197E-04 +C .... 0.00000e+00 6.21267E-05 32.938 -0.143 3.03598E-02 1.32197E-04 +C .... 0.00000E+00 6.21267E-05 32.938 -0.143 3.03598E-02 1.32197E-04 +BLANK card ending frequency cards +BLANK card ending "CABLE CONSTANTS" data subcases +BEGIN NEW DATA CASE +C 4th of 8 examples of cables without pipe: CASE21S2.DAT +CABLE CONSTANTS +CABLE PARAMETERS +C KOLW27 KOLS27 Only F? +MATRIX PRECISION 10 2 BOTH { Optimally encode both E and F +C About preceding 2 lines, which were added 7 December 2003: KOLW27 and KOLS27 +C are default values. BOTH in 45-48 is the request to have optimal encoding +C replace both alternative formats (ordinary E-field matrices as well as +C F-field matrices). Matrices have order 12, so without this treatment, +C E-field matrices would require multiple rows (first 10 columns, then 2 +C columns). Using BOTH, these multiple lines are avoided. 12 columns of +C 10 bytes each easily fit within the 131-byte limit. In fact, there is +C room for labeling on the right. +C 2 -1 6 0 0 0 0 -99 0 0 0 0 + 2 -1 6 0 1 0 0 -99 0 0 0 0 + 2 2 2 2 2 2 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 0.0 23.30E-3 49.80E-3 51.00E-3 56.00E-3 + 1.724E-8 1.0 1.4 2.7 1.724E-8 1.0 1.0 2.5 + 2.500 0.0 2.730 0.0 2.960 0.0 2.50 1.0 + 2.730 1.0 2.960 1.0 + 100. 50.E03 +C Modal transformation matrices follow. These are complex, with the real part displayed above the imaginary part. +C Transpose of the current transformation matrix [Ti] follows. This is the inverse of the voltage transformation matrix. +C By definition, [Ti] gives the mapping from modal to phase variables: i-phase = [Ti] * i-mode +C 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 1.00000 0.00000 +C 0.00000 0.00000 0.00000 -0.00001 0.00000 0.00000 0.00000 0.00000 +C .... 0.00000 0.00000 0.00000 0.00000 +C .... 0.00000 0.00000 0.00000 0.00000 +C +C MODE ATTENUATION VELOCITY IMPEDANCE (OHM/M) ADMITTANCE (S/M) CHARACT. IMP. (OHM) CHARACT. ADMIT. (S) +C NO. (DB/KM) (M/MIC.S) REAL IMAG. REAL IMAG. REAL IMAG. REAL IMAG. +C 1 1.98193E+01 11.24 4.54985E-02 2.76775E-01 0.00000E+00 2.80308E-03 +C 2 1.07741E-01 24.61 1.13061E-04 5.81815E-02 0.00000E+00 2.80120E-03 +C 3 6.30266E-02 43.96 1.48041E-04 7.29050E-02 0.00000E+00 7.00585E-04 +C 4 6.30266E-02 43.96 1.48002E-04 7.28856E-02 0.00000E+00 7.00772E-04 +C 5 6.30266E-02 43.96 1.11090E-04 5.47081E-02 0.00000E+00 9.33614E-04 +C 6 6.30266E-02 43.96 1.11001E-04 5.46642E-02 0.00000E+00 9.34363E-04 +C 7 7.73951E-02 153.52 5.86971E-04 6.73994E-02 0.00000E+00 6.21267E-05 +C 8 7.73951E-02 153.52 5.86971E-04 6.73994E-02 0.00000E+00 6.21267E-05 +C 9 7.73951E-02 153.52 5.86971E-04 6.73994E-02 0.00000E+00 6.21267E-05 +C 10 7.73951E-02 153.52 5.86971E-04 6.73994E-02 0.00000E+00 6.21267E-05 +C 11 7.73951E-02 153.52 5.86971E-04 6.73994E-02 0.00000E+00 6.21267E-05 +C 12 7.73950E-02 153.52 5.86971E-04 6.73994E-02 0.00000E+00 6.21267E-05 +BLANK card ending frequency cards +BLANK card ending "CABLE CONSTANTS" data subcases +BEGIN NEW DATA CASE +C 5th of 8 examples of cables without pipe: CASE22Y0.DAT +CABLE CONSTANTS +BRANCH CORA1 CORA2 SHEA1 SHEA2 +CABLE PARAMETERS +C KOLW27 KOLS27 Only F? +MATRIX PRECISION 10 2 +C The preceding 2 lines, added 7 Dec. 2003, restore the default choice. Note +C that there is no optional BOTH in columns 45-48 (see preceding subcase). +C 2 1 1 0 0 0 0 0 0 0 0 2 IPUNCH gone +C 2 1 1 0 0 0 0 0 0 0 0 + 2 1 1 0 1 0 0 0 0 0 0 +C 1 2.00 A + 2 + 0.8E-2 1.00E-2 2.70E-2 3.00E-2 3.10E-2 + 3.000E-8 1.0 1.0 1.063 3.000E-8 1.0 1.0 1.1 + 0.9 0.0 + 1.E-8 10.E06 1000. 2 +C Voltage transformation matrix [Tv]. This gives the mapping from modal to phase variables: v-phase = [Tv] * v-mode +C 1.00000 1.00000 +C 0.00000 0.00000 +C 0.00000 1.00000 +C 0.00000 0.00000 +C +C ADMITTANCE (S/M) CHARACT. IMP. (OHM) CHARACT. ADMIT. (S) +C REAL IMAG. REAL IMAG. REAL IMAG. +C .... 0.00000E+00 3.74095E-03 57.817 -0.055 1.72959E-02 1.64284E-05 +C .... 0.00000E+00 8.54359E-04 245.415 -0.014 4.07472E-03 2.33098E-07 +BLANK card ending frequency cards +$PUNCH, case22y0.pch ! { Of the 18 examples, this is 1st of 2 that punch +C $VINTAGE, 1 +C -1CORA1 CORA2 2.37561E-02 5.78171E+01 2.90497E+08-1.00000E+03 1 2 +C -2SHEA1 SHEA2 5.88727E-03 2.45415E+02 2.99666E+08-1.00000E+03 1 2 +C $VINTAGE, 0 +C 1.00000000 0.00000000 +C 0.00000000 0.00000000 +C -1.00000000 1.00000000 +C 0.00000000 0.00000000 +BLANK card ending "CABLE CONSTANTS" data subcases +BEGIN NEW DATA CASE +C 6th of 8 examples of cables without pipe: CASE22Y1.DAT +CABLE CONSTANTS +BRANCH CORA1 CORA2 SHEA1 SHEA2 +CABLE PARAMETERS +C 2 1 1 0 0 1 0 0 0 0 1 2 +C 2 1 1 0 0 1 0 0 0 0 1 + 2 1 1 0 1 1 0 0 0 0 1 +C 1 2.00 A + 2 + 0.8E-2 1.00E-2 2.70E-2 3.00E-2 3.10E-2 + 3.000E-8 1.0 1.0 1.063 3.000E-8 1.0 1.0 1.1 + 0.0 1.0E-15 0.0 0.055E-9 + 0.9 0.0 + 1.E-8 10.E06 1000. 2 +C EARTH IMPEDANCE ZE +C 1.11110E-04 1.11110E-04 +C 1.11111E-04 1.11111E-04 +C +C CONDUCTOR INTERNAL IMPEDANCE ZC +C 2.95323E-02 5.77615E-03 +C 1.29231E+01 4.17823E-01 +C +C MODE ATTENUATION VELOCITY IMPEDANCE (OHM/M) ADMITTANCE (S/M) +C NO. (DB/KM) (M/MIC.S) REAL IMAG. REAL IMAG. +C 1 2.34005E-01 133.42 5.88727E-03 5.14569E+01 0.00000E+00 4.31011E-03 +C 2 1.78448E+00 290.49 2.37561E-02 1.25053E+01 0.00000E+00 3.74102E-03 +BLANK card ending frequency cards +$PUNCH, case22y1.pch ! { Of the 18 examples, this is 2nd of 2 that punch +C $VINTAGE, 1 +C -1CORA1 CORA2 5.88727E-03 1.09264E+02 1.33418E+08-1.00000E+03 1 2 +C -2SHEA1 SHEA2 2.37561E-02 5.78166E+01 2.90494E+08-1.00000E+03 1 2 +C $VINTAGE, 0 +C 0.00000000 1.00000000 +C 0.00000000 0.00000000 +C 1.00000000 -1.00000000 +C 0.00000000 0.00000000 +BLANK card ending "CABLE CONSTANTS" data subcases +BEGIN NEW DATA CASE +C 7th of 8 examples of cables without pipe: CASE22Y2.DAT +CABLE CONSTANTS +CABLE PARAMETERS +C 2 1 1 0 0 0 0 0 0 0 2 0 + 2 1 1 0 1 0 0 0 0 0 2 0 + 2 + 0.8E-2 1.00E-2 2.70E-2 3.00E-2 3.10E-2 + 3.000E-8 1.0 1.0 1.063 3.000E-8 1.0 1.0 1.1 + 0.1E-14 0. 5.E-5 0. + 0.9 0.0 + 1.E-8 10.E06 1000. 1 +C ADMITTANCE (S/M) CHARACT. IMP. (OHM) CHARACT. ADMIT. (S) +C REAL IMAG. REAL IMAG. REAL IMAG. +C .... 0.00000E+00 3.74095E-03 57.817 -0.055 1.72959E-02 1.64284E-05 +C .... 5.00000E-05 8.54359E-04 245.101 7.152 4.07647E-03 -1.18949E-04 +BLANK card ending frequency cards +$PUNCH { Show Pi-circuit branch cards (1-punch in col 58 of frequency card) +C PI-EQUIVALENT MODEL WITH LENGTH= 0.100E+04(M) +C $VINTAGE, 1 +C 1 2.96433904E+01 1.01799070E+00 5.95391119E-02 +C 2 5.88726509E+00 8.18962579E-01 -5.95391119E-02 +C 5.88726509E+00 8.18962579E-01 7.31366522E-02 +C $VINTAGE, 0 +BLANK card ending "CABLE CONSTANTS" data subcases +BEGIN NEW DATA CASE +C 8th of 8 examples of cables without pipe: CASE22Y3.DAT +CABLE CONSTANTS +CABLE PARAMETERS + 2 1 1 0 0 0 0 0 0 0 3 0 + 2 + 0.8E-2 1.00E-2 2.70E-2 3.00E-2 3.10E-2 + 3.000E-8 1.0 1.0 1.063 3.000E-8 1.0 1.0 1.1 + 0.1E-14 1.0E-15 5.E-5 0.055E-9 + 0.9 0.0 + 1.E-8 10.E06 0 +C MODE ATTENUATION VELOCITY IMPEDANCE (OHM/M) ADMITTANCE (S/M) +C NO. (DB/KM) (M/MIC.S) REAL IMAG. REAL IMAG. +C 1 2.39603E+01 133.42 5.88727E-03 5.14569E+01 5.00000E-05 4.31011E-03 +C 2 1.78448E+00 290.49 2.37561E-02 1.25053E+01 0.00000E+00 3.74102E-03 +BLANK card ending frequency cards +BLANK card ending "CABLE CONSTANTS" data subcases +BEGIN NEW DATA CASE +C First of two examples of cables sent by Prof. Ametani on Feb. 17, 2001 +C that he used for verifying the correction he made in the calculation of +C conductor internal impedance of a cable having 3 layers of conductors, +C core, sheath, and armor. +C This is a one-phase SC cable with core and sheath only +CABLE PARAMETERS + 2 -1 1 0 1 1 0 0 0 0 0 + 2 + .7000E-01 .8000E-01 .9000E-01 .1000 .1100 + .1728E-07 1.000 1.000 2.200 .1728E-07 1.000 1.000 2.200 + 1.500 .0000 + 100.000 50.0000 0 0 0 +BLANK card ending frequency cards +BLANK card ending "CABLE PARAMETERS" data subcases +BEGIN NEW DATA CASE +C Second of two examples of cables sent by Prof. Ametani on Feb. 17, 2001 +C This is a one-phase SC cable with core, sheath, and armor. This data +C is almost the same as the previous one except having 3 conductors, and +C the physical configuration of the sheath and armor here is the same as +C the core and sheath of the previous case +CABLE PARAMETERS +C 2 -1 1 0 1 1 0 1 0 0 0 0 + 2 -1 1 0 1 1 0 0 0 0 0 + 3 + .5000E-01 .6000E-01 .7000E-01 .8000E-01 .9000E-01 .1000 .1100 + .1728E-07 1.000 1.000 2.200 .1728E-07 1.000 1.000 2.200 + .1728E-07 1.000 1.000 2.200 + 1.500 .0000 + 100.000 50.0000 0 0 0 +BLANK card ending frequency cards +BLANK card ending "CABLE PARAMETERS" data subcases +BEGIN NEW DATA CASE +BLANK +EOF + + + -- cgit v1.2.3