From b18347ffc9db9641e215995edea1c04c363b2bdf Mon Sep 17 00:00:00 2001 From: Angelo Rossi Date: Wed, 21 Jun 2023 12:04:16 +0000 Subject: Initial commit. --- benchmarks/dc17bins.dat | 60 +++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 60 insertions(+) create mode 100644 benchmarks/dc17bins.dat (limited to 'benchmarks/dc17bins.dat') diff --git a/benchmarks/dc17bins.dat b/benchmarks/dc17bins.dat new file mode 100644 index 0000000..1f3741d --- /dev/null +++ b/benchmarks/dc17bins.dat @@ -0,0 +1,60 @@ +/SOURCE +14GEN 377. 60. -1. +/TACS +TACS HYBRID + 1FLUX +GEN + 1.0 + 0.0 1.0 +90GEN +91GROUND +99CURR -1.0* GROUND +33FLUX GEN GROUNDCURR +/OUTPUT + GEN +/PLOT +C Last step: 400 .02 116.4994069 2.765761424 -2.76576141 .9416257618 +C Last step continued .....: 116.4994069 2.765761424 -2.76576142 +C Final 5 max. : 3.499909256 .9905492104 376.9925583 3.499613141 3.499909256 +C Associated times : .0125 .00415 .01665 .00415 .0125 + CALCOMP PLOT + 2Arbitrary 78-character case title text of which this is an example, I hope. + First of two lines of 78-byte graph subheading text. + Second and final such line of graph subheading text. + 194 2. 0.0 20. TACS CURR ABCDEFGHIJKLMNOP1234567890123456 + X-Y PLOT Horizontal Axis label123 + 10. -1.1 1.1 + 8. -4.0 4.0 + 194 4. 0.0 20. TACS FLUX TACS CURR Graph heading---Vertical axis la + X-Y PLOT Horizontal Axis label123 + 9999. -1.1 1.1 "9999." returns to conventional (vs. time) plotting + 8. -4.0 4.0 + PRINTER PLOT + 194 4. 0.0 20. TACS CURR { Axis limits: (-3.500, 3.500) +C Now that all plotting is done with, let's illustrate the three declarations +C that will choose the destination of any subsequent "CALCOMP PLOT" use: + SCREEN PLOT { If a vector plot were to follow, it would go only to the screen + PEN PLOT { If a vector plot were to follow, ... go only to CalComp plotter + SCREEN PEN { If a vector plot were to follow, .. go to both screen & plotter +C The preceding 3 declarations really could only be tested by a user who +C had both a vector-graphic screen and a CalComp plotter. Hence no use. +C The following active card of DC-33 must be disabled for $INSERT use. The +C problem is this. For $INCLUDE, the /LOAD FLOW disappears during data +C assembly, leaving just comment cards that have nothing to do with any load +C flow. So, they were tolerated. But not so for $INSERT which retains +C the data for this non-existent feature. So, remove entire block: +C /LOAD FLOW +/BRANCH +96GROUNDGEN 8888. 1.E-9 1 + 1.0 -0.7 + 2.0 0.9 + 3.5 1.0 + 9999. +/REQUEST +PRINTED NUMBER WIDTH, 13, 2, { Request maximum precision (for 8 output columns) +/INITIAL + 2GROUND 0. { Node voltage initial condition in fact changes nothing +C Initial conditions really are not a part of this problem, although we do want +C to illustrate that they, too, can be sorted, and inserted after /LOADFLOW +C The preceding redefinition of node voltage at GROUND changes zero to zero. +/SWITCH + GROUND MEASURING 1 -- cgit v1.2.3