From b18347ffc9db9641e215995edea1c04c363b2bdf Mon Sep 17 00:00:00 2001 From: Angelo Rossi Date: Wed, 21 Jun 2023 12:04:16 +0000 Subject: Initial commit. --- benchmarks/data_case_002.dat | 42 ++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 42 insertions(+) create mode 100644 benchmarks/data_case_002.dat (limited to 'benchmarks/data_case_002.dat') diff --git a/benchmarks/data_case_002.dat b/benchmarks/data_case_002.dat new file mode 100644 index 0000000..f9813fe --- /dev/null +++ b/benchmarks/data_case_002.dat @@ -0,0 +1,42 @@ +begin new data case +c RL.............................................Figure 3.10(b)................. +c Energization of an RL load. | +c ----dt<---tmax...............................................................| + 50.e-6 50.e-3 +c -Iprnt<--Iplot<-Idoubl<-KssOut<-MaxOut<---Ipun<-Memsav<---Icat + 15 1 0 0 0 1 +c +c Circuit data.................................................................. +c Bus-->Bus-->Bus-->Bus--><----R<----L<----C 0 + bus13 22.61 19.72 1 +blank End of circuit data......................................................| +c +c Switch data................................................................... +c Bus-->Bus--><---Tclose<----Topen<-------Ie 0 + src bus13 1.e-3 9999. 0 1 +blank End of switch data.......................................................| +c +c Source data................................................................... +c Bus--><---Tstart<----Tstop +14src 56.34 60. 0 0. -1. 9999. +blank End of source data.......................................................| +c +c Nodal Output Request Data..................................................... +c Bus-->Bus-->Bus-->Bus-->Bus-->Bus-->Bus-->Bus-->Bus-->Bus-->Bus-->Bus-->Bus--> + src bus13 +blank End of output requests...................................................| +c +c Plot request Data............................................................. + 2Figure 3.10(c): 3.10(d) +c ______Graph type: 4(volts) 8(branch volts) 9(currents) | +c | _____Units: 1(deg) 2(cyc) 3(sec) 4(msec) 5(microsec) | +c || _________Units per inch | +c || | _____Plot starting time | +c || | | _Plot stopping time | +c || | | | _____Value at bottom of vertical axis (optional) | +c || | | | | Value at top of vertical axis (optional) | +c VV<-|<--|<--|<---|---|Bus-->Bus-->Bus-->Bus-->Heading-------->Vert axis------> + 194 5. 0.0 50. -4. 4.src bus13 ENER 200MVA.95pfKAmps + 144 5. 0.0 50. bus13 ENER 200MVA.95pfKVolts +blank End of Plot Request Data.................................................| +blank End of All Cases -- cgit v1.2.3